Effect of endogenous reference genes on digital PCR assessment of genetically engineered canola events

Q1 Biochemistry, Genetics and Molecular Biology Biomolecular Detection and Quantification Pub Date : 2018-05-01 DOI:10.1016/j.bdq.2018.03.002
Tigst Demeke, Monika Eng
{"title":"Effect of endogenous reference genes on digital PCR assessment of genetically engineered canola events","authors":"Tigst Demeke,&nbsp;Monika Eng","doi":"10.1016/j.bdq.2018.03.002","DOIUrl":null,"url":null,"abstract":"<div><p>Droplet digital PCR (ddPCR) has been used for absolute quantification of genetically engineered (GE) events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences (<em>HMG-I/Y</em>, FatA(A), CruA and Ccf) for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A), reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the <em>HMG-I/Y</em> reference gene was less consistent than FatA(A) reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences) were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes.</p></div>","PeriodicalId":38073,"journal":{"name":"Biomolecular Detection and Quantification","volume":"15 ","pages":"Pages 24-29"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bdq.2018.03.002","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomolecular Detection and Quantification","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214753518300019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 16

Abstract

Droplet digital PCR (ddPCR) has been used for absolute quantification of genetically engineered (GE) events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences (HMG-I/Y, FatA(A), CruA and Ccf) for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A), reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the HMG-I/Y reference gene was less consistent than FatA(A) reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences) were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
内源内参基因对转基因油菜事件数字PCR评价的影响
液滴数字PCR (ddPCR)已用于基因工程(GE)事件的绝对定量。通过双工ddPCR对GE事件进行绝对定量,需要对靶基因和参比基因序列使用合适的引物和探针,以便准确地确定GE物质的数量。单拷贝内参基因通常是首选的绝对定量的GE事件的ddPCR。目前还没有研究对转基因油菜事件的ddPCR绝对定量的内参基因进行比较。研究了4个内源参考序列(HMG-I/Y、FatA(A)、CruA和Ccf)对转基因油菜事件的ddPCR绝对定量的适用性。研究了DNA提取方法和DNA质量对内参基因拷贝数评价的影响。使用单拷贝或双拷贝内参基因对ddPCR结果有影响。发现单拷贝FatA(A)内参基因是稳定的,适合用ddPCR进行转基因油菜事件的绝对定量。对于测量的拷贝数,HMG-I/Y内参基因的一致性低于FatA(A)内参基因。当使用CruA和Ccf(两拷贝内源性十字花素序列)时,由于拷贝数高,预期的ddPCR值被低估了。如果两个拷贝内参基因用于ddPCR,为了获得准确的结果,进行调整是很重要的。另一方面,实时定量PCR结果不受使用单拷贝或双拷贝内参基因的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomolecular Detection and Quantification
Biomolecular Detection and Quantification Biochemistry, Genetics and Molecular Biology-Biochemistry
CiteScore
14.20
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Publisher's Note Establishing essential quality criteria for the validation of circular RNAs as biomarkers qPCR data analysis: Better results through iconoclasm Considerations and quality controls when analyzing cell-free tumor DNA Next-generation sequencing of HIV-1 single genome amplicons
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1