Prosthetic complications with implant prostheses (2001-2017).

Q1 Dentistry European Journal of Oral Implantology Pub Date : 2018-01-01
Brian J Goodacre, Sarah E Goodacre, Charles J Goodacre
{"title":"Prosthetic complications with implant prostheses (2001-2017).","authors":"Brian J Goodacre,&nbsp;Sarah E Goodacre,&nbsp;Charles J Goodacre","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To present recent data regarding prosthetic complications with implant prostheses and crowns as well as compare this data with data presented in a 2003 publication.</p><p><strong>Material and methods: </strong>An electronic Medline (PubMed) with MeSH terms search was performed, focussing on clinical studies that reported data on prosthetic complications associated with implant fixed complete dentures, implant overdentures, implant fixed partial dentures, and implant single crowns.</p><p><strong>Results: </strong>There were nine prosthetic complications reported with implant fixed complete dentures, 17 with implant overdentures, four with implant fixed partial dentures, and six with implant single crowns. The greatest number of complications and the largest incidence of percentages occurred with implant overdentures. The lowest incidence percentages were recorded for implant single crowns. These findings are in agreement with the previous 2003 publication. It is of interest to note that some of the complications reported previously were not reported in this review, and some complications reported in this review were not listed in the 2003 publication, thereby limiting the number of direct comparisons between this paper and the earlier report. A surprising finding was that some complications associated with implant overdentures from the current data exceeded the incidence in 2003 (reactivation of the retentive attachment; mucosal hyperplasia; and the need for overdenture relines).</p><p><strong>Conclusions: </strong>Implant overdentures are associated with more complications than implant fixed complete dentures, implant fixed partial dentures, and implant single crowns. The lowest incidence of complications was reported with implant single crowns. The most common complication reported with implant fixed complete dentures was denture tooth fracture. The most common complication associated with implant overdentures was the need for adjustments. Porcelain veneer fracture/chipping was the most common complication identified in the studies of implant fixed partial dentures. The most common complication reported with implant single crowns was abutment screw loosening.</p>","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"11 Suppl 1 ","pages":"S27-S36"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To present recent data regarding prosthetic complications with implant prostheses and crowns as well as compare this data with data presented in a 2003 publication.

Material and methods: An electronic Medline (PubMed) with MeSH terms search was performed, focussing on clinical studies that reported data on prosthetic complications associated with implant fixed complete dentures, implant overdentures, implant fixed partial dentures, and implant single crowns.

Results: There were nine prosthetic complications reported with implant fixed complete dentures, 17 with implant overdentures, four with implant fixed partial dentures, and six with implant single crowns. The greatest number of complications and the largest incidence of percentages occurred with implant overdentures. The lowest incidence percentages were recorded for implant single crowns. These findings are in agreement with the previous 2003 publication. It is of interest to note that some of the complications reported previously were not reported in this review, and some complications reported in this review were not listed in the 2003 publication, thereby limiting the number of direct comparisons between this paper and the earlier report. A surprising finding was that some complications associated with implant overdentures from the current data exceeded the incidence in 2003 (reactivation of the retentive attachment; mucosal hyperplasia; and the need for overdenture relines).

Conclusions: Implant overdentures are associated with more complications than implant fixed complete dentures, implant fixed partial dentures, and implant single crowns. The lowest incidence of complications was reported with implant single crowns. The most common complication reported with implant fixed complete dentures was denture tooth fracture. The most common complication associated with implant overdentures was the need for adjustments. Porcelain veneer fracture/chipping was the most common complication identified in the studies of implant fixed partial dentures. The most common complication reported with implant single crowns was abutment screw loosening.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
假体并发症(2001-2017)。
目的:介绍种植体和牙冠并发症的最新数据,并将此数据与2003年发表的数据进行比较。材料和方法:通过电子医学检索(PubMed)进行MeSH术语搜索,重点关注与种植固定全口义齿、种植覆盖义齿、种植固定局部义齿和种植单冠相关的义肢并发症的临床研究。结果:种植固定全口义齿9例,种植覆盖义齿17例,种植固定局部义齿4例,种植单冠义齿6例。种植覆盖义齿的并发症最多,发生率最高。单冠种植体的发生率最低。这些发现与2003年发表的文章一致。值得注意的是,之前报道的一些并发症在本综述中没有报道,并且本综述中报道的一些并发症没有在2003年的出版物中列出,从而限制了本文与早期报道之间直接比较的数量。一个令人惊讶的发现是,从目前的数据来看,与种植覆盖义齿相关的一些并发症的发生率超过了2003年的发生率(固位附着体的重新激活;粘膜增生;以及对覆盖假牙线的需求)。结论:种植覆盖义齿并发症发生率高于种植固定全口义齿、种植固定局部义齿和种植单冠义齿。单冠种植的并发症发生率最低。种植固定全口义齿最常见的并发症是义齿断裂。种植覆盖义齿最常见的并发症是需要调整。烤瓷贴面断裂/脱落是种植固定部分义齿研究中最常见的并发症。单冠种植最常见的并发症是基牙螺钉松动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Journal of Oral Implantology
European Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.35
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Immediate loading of fixed prostheses in fully edentulous jaws - 1-year follow-up from a single-cohort retrospective study. Research in focus. Dental implants with internal versus external connections: 1-year post-loading results from a pragmatic multicenter randomised controlled trial. Research in focus. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1