{"title":"The change of QRS duration after pulmonary valve replacement in patients with repaired tetralogy of Fallot and pulmonary regurgitation.","authors":"Yuni Yun, Yeo Hyang Kim, Jung Eun Kwon","doi":"10.3345/kjp.2018.06765","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF).</p><p><strong>Methods: </strong>Children and adolescents who had previously undergone total repair for TOF (n=67; median age, 16 years) who required elective PVR for pulmonary regurgitation and/or right ventricular out tract obstruction were included in this study. The QRS duration and CTR were measured pre- and postoperatively and postoperative changes were evaluated.</p><p><strong>Results: </strong>Following PVR, the CTR significantly decreased (pre-PVR 57.2%±6.2%, post-PVR 53.8%±5.5%, P=0.002). The postoperative QRS duration showed a tendency to decrease (pre-PVR 162.7±26.4 msec, post-PVR 156.4±24.4 msec, P=0.124). QRS duration was greater than 180 msec in 6 patients prior to PVR. Of these, 5 patients showed a decrease in QRS duration following PVR; QRS duration was less than 180 msec in 2 patients, and QRS duration remained greater than 180 msec in 3 patients, including 2 patients with diffuse postoperative right ventricular outflow tract hypokinesis. Six patients had coexisting arrhythmias before PVR; 2 patients, atrial tachycardia; 3 patients, premature ventricular contraction; and 1 patient, premature atrial contraction. None of the patients presented with arrhythmia following PVR.</p><p><strong>Conclusion: </strong>The CTR and QRS duration reduced following PVR. However, QRS duration may not decrease below 180 msec after PVR, particularly in patients with right ventricular outflow tract hypokinesis. The CTR and ECG may provide additional clinical information on changes in right ventricular volume and/or pressure in these patients.</p>","PeriodicalId":17863,"journal":{"name":"Korean Journal of Pediatrics","volume":"61 11","pages":"362-365"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/48/03/kjp-2018-06765.PMC6258967.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Pediatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3345/kjp.2018.06765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/10/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Purpose: This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF).
Methods: Children and adolescents who had previously undergone total repair for TOF (n=67; median age, 16 years) who required elective PVR for pulmonary regurgitation and/or right ventricular out tract obstruction were included in this study. The QRS duration and CTR were measured pre- and postoperatively and postoperative changes were evaluated.
Results: Following PVR, the CTR significantly decreased (pre-PVR 57.2%±6.2%, post-PVR 53.8%±5.5%, P=0.002). The postoperative QRS duration showed a tendency to decrease (pre-PVR 162.7±26.4 msec, post-PVR 156.4±24.4 msec, P=0.124). QRS duration was greater than 180 msec in 6 patients prior to PVR. Of these, 5 patients showed a decrease in QRS duration following PVR; QRS duration was less than 180 msec in 2 patients, and QRS duration remained greater than 180 msec in 3 patients, including 2 patients with diffuse postoperative right ventricular outflow tract hypokinesis. Six patients had coexisting arrhythmias before PVR; 2 patients, atrial tachycardia; 3 patients, premature ventricular contraction; and 1 patient, premature atrial contraction. None of the patients presented with arrhythmia following PVR.
Conclusion: The CTR and QRS duration reduced following PVR. However, QRS duration may not decrease below 180 msec after PVR, particularly in patients with right ventricular outflow tract hypokinesis. The CTR and ECG may provide additional clinical information on changes in right ventricular volume and/or pressure in these patients.
期刊介绍:
Korean J Pediatr covers clinical and research works relevant to all aspects of child healthcare. The journal aims to serve pediatricians through the prompt publication of significant advances in any field of pediatrics and to rapidly disseminate recently updated knowledge to the public. Additionally, it will initiate dynamic, international, academic discussions concerning the major topics related to pediatrics. Manuscripts are categorized as review articles, original articles, and case reports. Areas of specific interest include: Growth and development, Neonatology, Pediatric neurology, Pediatric nephrology, Pediatric endocrinology, Pediatric cardiology, Pediatric allergy, Pediatric pulmonology, Pediatric infectious diseases, Pediatric immunology, Pediatric hemato-oncology, Pediatric gastroenterology, Nutrition, Human genetics, Metabolic diseases, Adolescence medicine, General pediatrics.