[Influence of Propofol and Remifentanil on Pupillary Light Reflex Assessed by a Hand-held Point-and-shoot Pupillometer].

Takuo Hoshi
{"title":"[Influence of Propofol and Remifentanil on Pupillary Light Reflex Assessed by a Hand-held Point-and-shoot Pupillometer].","authors":"Takuo Hoshi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Anisocoria and abnormality of pupil- lary light reflex may indicate sight-threatening or life- threatening neurological injury. Many perioperative patients are given opioids for analgesia, and opioids produce miosis and make it hard to assess anisocoria or pupillary light reflex. This study was designed to determine the influence of induction of anesthesia on pupillary light reflex assessed by a hand-held point- and-shoot pupillometer.</p><p><strong>Methods: </strong>Eighteen patients receiving general anes- thesia were enrolled. Anesthesia was inducted by remifentanil, propofol and rocuronium after' pre-oxy- genation and tracheal intubation or insertion of supra- glottic airway device. The pupillary measurement data before induction and after intubation or insertion of supraglottic airway device were taken from records.</p><p><strong>Results: </strong>With eighteen patients, thirty six eye data were compared. After intravenous injection of propofol and remifentanil infusion, pupils were constricted from 4.0±1.1 mm to 1.8±0.4 mm, and average constriction velocity (CV), neurological pupil index (NPI) measured automatically from light reflex decreased for 2.5±0.9 mm, sec⁻¹ to 0.3±0.2 mm · sec⁻¹, 4.4±0.4 to 3.9±0.4, respectively (P<0.0001).</p><p><strong>Conclusions: </strong>Propofol and remifentanil infusion in- fluence pupillary light reflex and decreases values of NPI and CV. When using these drugs, it is necessary to perform neurologic evaluation using NPI and CV.</p>","PeriodicalId":18254,"journal":{"name":"Masui. The Japanese journal of anesthesiology","volume":"66 2","pages":"174-176"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Masui. The Japanese journal of anesthesiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Anisocoria and abnormality of pupil- lary light reflex may indicate sight-threatening or life- threatening neurological injury. Many perioperative patients are given opioids for analgesia, and opioids produce miosis and make it hard to assess anisocoria or pupillary light reflex. This study was designed to determine the influence of induction of anesthesia on pupillary light reflex assessed by a hand-held point- and-shoot pupillometer.

Methods: Eighteen patients receiving general anes- thesia were enrolled. Anesthesia was inducted by remifentanil, propofol and rocuronium after' pre-oxy- genation and tracheal intubation or insertion of supra- glottic airway device. The pupillary measurement data before induction and after intubation or insertion of supraglottic airway device were taken from records.

Results: With eighteen patients, thirty six eye data were compared. After intravenous injection of propofol and remifentanil infusion, pupils were constricted from 4.0±1.1 mm to 1.8±0.4 mm, and average constriction velocity (CV), neurological pupil index (NPI) measured automatically from light reflex decreased for 2.5±0.9 mm, sec⁻¹ to 0.3±0.2 mm · sec⁻¹, 4.4±0.4 to 3.9±0.4, respectively (P<0.0001).

Conclusions: Propofol and remifentanil infusion in- fluence pupillary light reflex and decreases values of NPI and CV. When using these drugs, it is necessary to perform neurologic evaluation using NPI and CV.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[用手持式傻瓜瞳孔计评估异丙酚和瑞芬太尼对瞳孔光反射的影响]。
背景:瞳孔光反射的异色和异常可能提示威胁视力或生命的神经损伤。许多围手术期患者给予阿片类药物镇痛,阿片类药物产生瞳孔缩小,使瞳孔内焦或瞳孔光反射难以评估。本研究旨在确定麻醉诱导对瞳孔光反射的影响,通过手持式瞳孔测量仪进行评估。方法:纳入18例接受全身麻醉的患者。采用瑞芬太尼、异丙酚和罗库溴铵进行麻醉,经预氧、气管插管或置放声门上气道装置。从记录中取诱导前及插管或插入声门上气道装置后瞳孔测量数据。结果:对18例患者36眼资料进行比较。静脉注射异丙酚和瑞芬太尼后,瞳孔从4.0±1.1 mm缩小到1.8±0.4 mm,平均收缩速度(CV)和神经学瞳孔指数(NPI)由光反射自动测量分别从2.5±0.9 mm,秒(⁻¹)到0.3±0.2 mm·秒(⁻¹),4.4±0.4到3.9±0.4(结论:异丙酚和瑞芬太尼注射影响瞳孔光反射和NPI、CV的降低值。在使用这些药物时,有必要使用NPI和CV进行神经学评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Hypertrophic cardiomyopathy]. Point-of-care Lung Ultrasound. Point-of-care Abdominal Ultrasound. Vascular Access and Diagnosis of Venous Thrombosis. The PEAS Protocol, an Airway Ultrasound Technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1