{"title":"Effect of Molding Technique on Iwo Physical Properties of Acrylic Resin Specimens.","authors":"Jafar Gharechahi, Nafiseh Asadzadeh, Foad Shahabian, Maryam Gharechahi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to compare dimensional changes and flexural strength of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot Resin was used for conventional pressure-packed, and SR-Ivocap High Impact was used for injection-molding techniques. Measurements were recorded at 24-hour, 48-hour and 12-day intervals. Three-point test and statistical analysis were carried out. After each water storage period, the acrylic specimens produced by injection method exhibited less dimensional change compared to those produced by the conventional technique. Within the limitation of this study, dimensional changes and flexural strength of acrylic resin specimens were influenced by molding technique, and the SR-Ivocap injection procedure exhibited higher dimensional accuracy and flexural strength compared to conventional molding.</p>","PeriodicalId":23026,"journal":{"name":"The New York state dental journal","volume":"82 4","pages":"38-44"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The New York state dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study was to compare dimensional changes and flexural strength of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot Resin was used for conventional pressure-packed, and SR-Ivocap High Impact was used for injection-molding techniques. Measurements were recorded at 24-hour, 48-hour and 12-day intervals. Three-point test and statistical analysis were carried out. After each water storage period, the acrylic specimens produced by injection method exhibited less dimensional change compared to those produced by the conventional technique. Within the limitation of this study, dimensional changes and flexural strength of acrylic resin specimens were influenced by molding technique, and the SR-Ivocap injection procedure exhibited higher dimensional accuracy and flexural strength compared to conventional molding.
本研究的目的是比较尺寸变化和试样的弯曲强度处理的常规和注射成型技术。常规压力填充采用SR-Ivocap三复合热树脂,注射成型技术采用SR-Ivocap High Impact。每隔24小时、48小时和12天记录一次测量结果。进行三点检验和统计分析。在每个蓄水期后,注射法制备的亚克力样品尺寸变化均小于常规法制备的亚克力样品。在本研究范围内,丙烯酸树脂样品的尺寸变化和抗弯强度受成型工艺的影响,SR-Ivocap注射工艺与常规成型工艺相比具有更高的尺寸精度和抗弯强度。