Determination of Trace Amounts of Lead Using the Flotation-spectrophotometric method.

Analytical Chemistry Insights Pub Date : 2011-03-01 eCollection Date: 2011-01-01 DOI:10.4137/ACI.S5948
Sabah Shiri, Ali Delpisheh, Ali Haeri, Abdolhossein Poornajaf, Babak Golzadeh, Sina Shiri
{"title":"Determination of Trace Amounts of Lead Using the Flotation-spectrophotometric method.","authors":"Sabah Shiri,&nbsp;Ali Delpisheh,&nbsp;Ali Haeri,&nbsp;Abdolhossein Poornajaf,&nbsp;Babak Golzadeh,&nbsp;Sina Shiri","doi":"10.4137/ACI.S5948","DOIUrl":null,"url":null,"abstract":"<p><p>The present study describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of extremely low concentrations of lead. It is based on flotation of a complex of Pb<sup>2+</sup> ions and Alizarin yellow between aqueous and <i>n</i>-hexane interface at pH = 6. The proposed procedure is also applied for determination of lead in both tap water and prepared sea water samples. Beer's Law was obeyed over the concentration range of 3.86 × 10<sup>-8</sup> To 8.20 × 10<sup>-7</sup> molL<sup>-1</sup> (8-170 ngmL<sup>-1</sup>) with an apparent molar absorptivity of 1.33 × 10<sup>6</sup> molL<sup>-1</sup> cm<sup>-1</sup> for a 100 mL aliquot of the water sample. The detection limit (n = 10) was 8.7 × 10<sup>-9</sup> molL<sup>-1</sup> (1.0 ngmL<sup>-1</sup>) and the Relative standard deviation (R.S.D), (n = 10) for 7.2 × 10<sup>-7</sup> molL<sup>-1</sup> (150 ngmL<sup>-1</sup>) of Pb (II) was 4.36%. A notable advantage of the method is that the determination of Pb (II) is free from the interference of almost all cations and ions found in the environment and waste water samples. The determination of Pb (II) in tap and synthetic seawater samples was also carried out by the present method. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S5948","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/ACI.S5948","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The present study describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of extremely low concentrations of lead. It is based on flotation of a complex of Pb2+ ions and Alizarin yellow between aqueous and n-hexane interface at pH = 6. The proposed procedure is also applied for determination of lead in both tap water and prepared sea water samples. Beer's Law was obeyed over the concentration range of 3.86 × 10-8 To 8.20 × 10-7 molL-1 (8-170 ngmL-1) with an apparent molar absorptivity of 1.33 × 106 molL-1 cm-1 for a 100 mL aliquot of the water sample. The detection limit (n = 10) was 8.7 × 10-9 molL-1 (1.0 ngmL-1) and the Relative standard deviation (R.S.D), (n = 10) for 7.2 × 10-7 molL-1 (150 ngmL-1) of Pb (II) was 4.36%. A notable advantage of the method is that the determination of Pb (II) is free from the interference of almost all cations and ions found in the environment and waste water samples. The determination of Pb (II) in tap and synthetic seawater samples was also carried out by the present method. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用浮选-分光光度法测定微量铅。
本研究描述了一种简单、高选择性的分离、预富集和分光光度法测定极低浓度铅的方法。它是基于Pb2+离子与茜素黄的络合物在pH = 6的水溶液和正己烷界面之间的浮选。所建议的程序也适用于自来水和制备的海水样品中的铅的测定。在3.86 × 10-8 ~ 8.20 × 10-7 mol -1 (8-170 ngmL-1)浓度范围内符合比尔定律,对100 mL等分水样的表观摩尔吸收率为1.33 × 106 mol -1 cm-1。Pb (II)的检出限(n = 10)为8.7 × 10-9 mol -1 (1.0 ngmL-1),相对标准偏差(R.S.D) (n = 10)为4.36%。该方法的一个显著优点是Pb (II)的测定不受环境和废水样品中几乎所有阳离子和离子的干扰。本文还对自来水和人工海水样品中的铅(II)进行了测定。结果具有令人满意的可比性,从而证实了该方法对实际样品的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Accurate Assessment of Docosahexaenoic Acid in Laying Hen Serum for Regulatory Studies. In Vitro Studies of the Antimicrobial and Free-Radical Scavenging Potentials of Silver Nanoparticles Biosynthesized From the Extract of Desmostachya bipinnata. Analytical Methods for the Determination of Mineral Oil Saturated Hydrocarbons (MOSH) and Mineral Oil Aromatic Hydrocarbons (MOAH)-A Short Review. Chitosan Membrane Embedded With ZnO/CuO Nanocomposites for the Photodegradation of Fast Green Dye Under Artificial and Solar Irradiation. Ten Basic Rules of Antibody Validation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1