[How to Interpret Routine Laboratory Data? Challenge Faced by Inexperienced Certified Clinical Laboratory Physicians -Practical Advice from Experienced Certified Clinical Laboratory Physicians -].

Osamu Yonekawa, Takayuki Honda
{"title":"[How to Interpret Routine Laboratory Data? Challenge Faced by Inexperienced Certified Clinical Laboratory Physicians -Practical Advice from Experienced Certified Clinical Laboratory Physicians -].","authors":"Osamu Yonekawa,&nbsp;Takayuki Honda","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>At the annual meeting of the Japanese Society of Laboratory Medicine in Kobe in 2016, a joint symposium was held in cooperation between the Japanese Society of Laboratory Medicine and Japanese Association of Clinical Laboratory Physicians. We presented and discussed 5 cases at the Reversed Clinico-pathological Conference. Each case was analyzed by 5 new members of the Japanese Association of Clinical Laboratory Physicians, who had passed the examination for Certified Clinical Laboratory Physicians in 2015. After the presentation of their interpretation for basic laboratory tests, the correct diagnosis and useful practical advice were given by experienced Certified Clinical Laboratory Physicians. The first case involved hemolytic anemia due to valve replacement and multiple myeloma with the BJP type. The second case involved primary aldos- teronism with hypokalemia. The third case involved cold agglutination with a high value of MCHC. The fourth case involved pneumonia due to influenza virus. The last case involved diabetic ketoacidosis. All 5 cases were common rather than rare, and any members of the clinical laboratories may encounter them in routine work. A systemic analysis of routine laboratory data can sometimes directly lead to the correct diag- nosis using laboratory data alone and give doctors valuable clinical information on patients. Continuous daily efforts in systemic analysis will ensure that the evaluation skills of inexperienced Certified Clinical Laboratory Physicians in their hospitals will increase. Certified Clinical Laboratory Physicians in clinical laboratories are gatekeepers in every hospital from the viewpoints of both \"medical audit\" and \"risk management\".</p>","PeriodicalId":21457,"journal":{"name":"Rinsho byori. The Japanese journal of clinical pathology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho byori. The Japanese journal of clinical pathology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

At the annual meeting of the Japanese Society of Laboratory Medicine in Kobe in 2016, a joint symposium was held in cooperation between the Japanese Society of Laboratory Medicine and Japanese Association of Clinical Laboratory Physicians. We presented and discussed 5 cases at the Reversed Clinico-pathological Conference. Each case was analyzed by 5 new members of the Japanese Association of Clinical Laboratory Physicians, who had passed the examination for Certified Clinical Laboratory Physicians in 2015. After the presentation of their interpretation for basic laboratory tests, the correct diagnosis and useful practical advice were given by experienced Certified Clinical Laboratory Physicians. The first case involved hemolytic anemia due to valve replacement and multiple myeloma with the BJP type. The second case involved primary aldos- teronism with hypokalemia. The third case involved cold agglutination with a high value of MCHC. The fourth case involved pneumonia due to influenza virus. The last case involved diabetic ketoacidosis. All 5 cases were common rather than rare, and any members of the clinical laboratories may encounter them in routine work. A systemic analysis of routine laboratory data can sometimes directly lead to the correct diag- nosis using laboratory data alone and give doctors valuable clinical information on patients. Continuous daily efforts in systemic analysis will ensure that the evaluation skills of inexperienced Certified Clinical Laboratory Physicians in their hospitals will increase. Certified Clinical Laboratory Physicians in clinical laboratories are gatekeepers in every hospital from the viewpoints of both "medical audit" and "risk management".

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
如何解释常规实验室数据?经验不足的注册临床实验室医生面临的挑战-经验丰富的注册临床实验室医生的实用建议-]。
2016年在神户举行的日本检验医学学会年会上,日本检验医学学会与日本临床检验医师协会合作举办了联合研讨会。我们在逆向临床病理会议上报告并讨论了5例病例。每个病例由5名2015年通过临床检验医师资格考试的日本临床检验医师协会新会员进行分析。在介绍了他们对基本实验室检查的解释之后,经验丰富的注册临床实验室医生给出了正确的诊断和有用的实用建议。第一个病例涉及瓣膜置换术引起的溶血性贫血和BJP型多发性骨髓瘤。第二个病例涉及原发性aldo - teronism伴低血钾。第三例为冷凝集,MCHC值高。第四个病例涉及流感病毒引起的肺炎。最后一例为糖尿病酮症酸中毒。5例病例均为常见病,临床实验室工作人员在日常工作中均有可能遇到。对常规实验室数据的系统分析有时可以直接导致仅使用实验室数据的正确诊断,并为医生提供有关患者的宝贵临床信息。在系统分析方面的持续日常努力将确保医院中缺乏经验的注册临床实验室医师的评估技能将得到提高。无论是从“医疗审计”还是“风险管理”的角度来看,临床实验室注册医师都是每家医院的守门人。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Candida]. [Bleeding time]. [Microparticle]. [Aldolase]. [Telomerase].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1