[The Technical Evaluation of HCV Screening Assay].

Yoko Kobayashi, Masami Tomoda, Hitomi Miura, Asako Satho
{"title":"[The Technical Evaluation of HCV Screening Assay].","authors":"Yoko Kobayashi,&nbsp;Masami Tomoda,&nbsp;Hitomi Miura,&nbsp;Asako Satho","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Advances in treatment have resulted in a high rate of sustained virological response in patients with hepati- tis C, whereas many asymptomatic carriers of hepatitis C virus (HCV) remain untreated. Therefore, HCV antibody screening holds great significance. However, the measurement principles or types of antigen used in screening vary according to the manufacturer, leading to discrepancies in the results obtained using differ- ent screening reagents. In this study, the performances of five HCV antibody screening assays - ARCHITECT HCV, ECLusys Anti-HCV II assay, HISCL HCV Ab assay, LUMIPULSE II Ortho HCV, and LUMIPULSE Presto Ortho HCV- were compared using 2,042 serum samples. The positive rates for the various assays ranged from 3.6% to 4.5%, and 1,937 and 70 samples were determined as negative and positive, respectively. Discordant results were obtained for 35 samples (1.7%). Additional confirmatory testing was performed on 105 samples that tested positive with at least one reagent. Thus, of the 35 samples with discordant results, 24 single-positive samples were highly likely to be false-positive and 5 single-negative sam- ples were likely to be truly positive. Considering that HCV antibody would not be missed by any assay, those showing no or minimal non-specific or crossover reactions would be ideal for HCV antibody screening. Indeed, further improvement of screening reagents is also needed.</p>","PeriodicalId":21457,"journal":{"name":"Rinsho byori. The Japanese journal of clinical pathology","volume":"65 2","pages":"147-152"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho byori. The Japanese journal of clinical pathology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Advances in treatment have resulted in a high rate of sustained virological response in patients with hepati- tis C, whereas many asymptomatic carriers of hepatitis C virus (HCV) remain untreated. Therefore, HCV antibody screening holds great significance. However, the measurement principles or types of antigen used in screening vary according to the manufacturer, leading to discrepancies in the results obtained using differ- ent screening reagents. In this study, the performances of five HCV antibody screening assays - ARCHITECT HCV, ECLusys Anti-HCV II assay, HISCL HCV Ab assay, LUMIPULSE II Ortho HCV, and LUMIPULSE Presto Ortho HCV- were compared using 2,042 serum samples. The positive rates for the various assays ranged from 3.6% to 4.5%, and 1,937 and 70 samples were determined as negative and positive, respectively. Discordant results were obtained for 35 samples (1.7%). Additional confirmatory testing was performed on 105 samples that tested positive with at least one reagent. Thus, of the 35 samples with discordant results, 24 single-positive samples were highly likely to be false-positive and 5 single-negative sam- ples were likely to be truly positive. Considering that HCV antibody would not be missed by any assay, those showing no or minimal non-specific or crossover reactions would be ideal for HCV antibody screening. Indeed, further improvement of screening reagents is also needed.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[HCV筛选试验技术评价]。
治疗的进步导致丙型肝炎患者持续病毒学应答率很高,而许多无症状的丙型肝炎病毒(HCV)携带者仍未得到治疗。因此,HCV抗体筛选具有重要意义。然而,在筛选中使用的抗原的测量原理或类型因制造商而异,导致使用不同的筛选试剂获得的结果存在差异。在这项研究中,比较了5种HCV抗体筛选方法(ARCHITECT HCV, ECLusys Anti-HCV II assay, HISCL HCV Ab assay, LUMIPULSE II Ortho HCV和LUMIPULSE Presto Ortho HCV)的性能,使用2042份血清样本。各种检测方法的阳性率在3.6% ~ 4.5%之间,分别有1937份和70份样品被确定为阴性和阳性。35个样本(1.7%)的结果不一致。对至少一种试剂检测呈阳性的105个样本进行了进一步的确认检测。因此,在35个结果不一致的样本中,24个单阳性样本极有可能是假阳性,5个单阴性样本极有可能是真阳性。考虑到HCV抗体不会被任何检测遗漏,那些没有或只有很少的非特异性或交叉反应的抗体将是HCV抗体筛选的理想选择。确实,筛选试剂也需要进一步改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Candida]. [Bleeding time]. [Microparticle]. [Aldolase]. [Telomerase].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1