Saiprasad O Kavthekar, Ashok A Chougule, Swati S Kavthekar, Anil B Kurane, Sachin Verma
{"title":"Assessment of preferable site for temperature measurement using non-contact infra-red temperature among pediatric patients.","authors":"Saiprasad O Kavthekar, Ashok A Chougule, Swati S Kavthekar, Anil B Kurane, Sachin Verma","doi":"10.23736/S2724-5276.20.05755-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate temperature measurement with little or no discomfort that is safe, without risk of hospital-acquired infections or perforations, is the preferred choice of medical professionals in pediatric settings. The objective was to discover the preferable site for body temperature measurement using non-contact infra-red thermometer (NCIT) among pediatric patients.</p><p><strong>Methods: </strong>NCIT measurement at mid forehead (F), right temporal region (T), right side of neck-over-carotid artery area (N), jugular notch (J), sternum (S), umbilical region and sublingual region (U) were compared with digital axillary temperature (DAT) in a single attempt in 500 patients, aged between 2 to 5 years with fever. Data was analyzed using Pearson's correlation, paired t-test and Bland-Altman plot to assess the correlation and agreement between the DAT and NCIT sites.</p><p><strong>Results: </strong>The mean temperature of NCIT-T (38.42±0.64 °C) was more agreeable with DAT (38.42±0.63 °C) compared to other body sites. The minimum mean bias of -0.00480 °C was noted for NCIT-F with 95% CI of -0.164-0.15; however, NCIT-F revealed many outliers as compared to NCIT-J. A strong positive correlation existed between DAT and NCIT sites (r value: 0.99-0.98). However, significant difference was found between DAT and NCIT-N, NCIT-F and NCIT-U (P<0.0001).</p><p><strong>Conclusions: </strong>NCIT-J is the most preferable choice for measuring body temperature and can be interchanged with DAT. It will help to deliver fast results with enhanced patient comfort due to its non-invasive nature.</p>","PeriodicalId":18533,"journal":{"name":"Minerva pediatrica","volume":" ","pages":"7-12"},"PeriodicalIF":2.6000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva pediatrica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5276.20.05755-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/5/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Accurate temperature measurement with little or no discomfort that is safe, without risk of hospital-acquired infections or perforations, is the preferred choice of medical professionals in pediatric settings. The objective was to discover the preferable site for body temperature measurement using non-contact infra-red thermometer (NCIT) among pediatric patients.
Methods: NCIT measurement at mid forehead (F), right temporal region (T), right side of neck-over-carotid artery area (N), jugular notch (J), sternum (S), umbilical region and sublingual region (U) were compared with digital axillary temperature (DAT) in a single attempt in 500 patients, aged between 2 to 5 years with fever. Data was analyzed using Pearson's correlation, paired t-test and Bland-Altman plot to assess the correlation and agreement between the DAT and NCIT sites.
Results: The mean temperature of NCIT-T (38.42±0.64 °C) was more agreeable with DAT (38.42±0.63 °C) compared to other body sites. The minimum mean bias of -0.00480 °C was noted for NCIT-F with 95% CI of -0.164-0.15; however, NCIT-F revealed many outliers as compared to NCIT-J. A strong positive correlation existed between DAT and NCIT sites (r value: 0.99-0.98). However, significant difference was found between DAT and NCIT-N, NCIT-F and NCIT-U (P<0.0001).
Conclusions: NCIT-J is the most preferable choice for measuring body temperature and can be interchanged with DAT. It will help to deliver fast results with enhanced patient comfort due to its non-invasive nature.
期刊介绍:
Minerva Pediatrica publishes scientific papers on pediatrics, neonatology, adolescent medicine, child and adolescent psychiatry and pediatric surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, special articles, letters to the Editor and guidelines. The journal aims to provide its readers with papers of the highest quality and impact through a process of careful peer review and editorial work.