Ultrasonography to Assess the Efficacy of Osteopathic Manipulative Treatment for Lumbar Spine Asymmetry.

Jeffrey Winter, Andrew Kimber, Stuart Montenegro, Jing Gao
{"title":"Ultrasonography to Assess the Efficacy of Osteopathic Manipulative Treatment for Lumbar Spine Asymmetry.","authors":"Jeffrey Winter,&nbsp;Andrew Kimber,&nbsp;Stuart Montenegro,&nbsp;Jing Gao","doi":"10.7556/jaoa.2020.127","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The effectiveness of osteopathic manipulative treatment (OMT) on the lumbar spine has been studied qualitatively, but quantitative measurement of the effects of OMT has not been thoroughly investigated.</p><p><strong>Objective: </strong>To quantitatively measure the palpated improvements of OMT on the lumbar spine using ultrasonography (US) and correlate palpatory diagnosis with US measurements of lumbar asymmetry.</p><p><strong>Methods: </strong>From September to November 2018, we recruited 20 adult participants 18 years of age or older. Lumbar somatic dysfunction (SD) was identified via osteopathic palpation. US was then performed on all participants with standard machine settings (frequency, 7 MHz; depth, 7 cm; dynamic range, 60; tissue harmonic imaging; and single-image focus). Longitudinal images of each lumbar transverse process were recorded and saved bilaterally by an experienced radiologist and a medical student. The participant's SD was then managed using OMT, including Still technique, myofascial release, muscle energy technique, high-velocity low-amplitude technique, functional positional release, balanced ligamentous tension, and counterstrain. Following OMT, US was performed again in the same method. Measurements of the saved US images were reviewed using a Digital Imaging and Communications in Medicine viewer. These measurements were obtained by 3 separate observers (J.W., A.K., S.M.), using the same computer software. Statistical analysis included a 2-tailed paired t-test to analyze rotational asymmetry pre- and posttreatment, an intraclass correlation coefficient (ICC) to test intra- and interobserver reliability, and a Pearson correlation coefficient (PCC) to analyze the correlation between US findings and OMT.</p><p><strong>Results: </strong>The difference in soft tissue thickness before and after OMT was significant (P=.014), indicating improvements in rotational asymmetry. Side-bending asymmetry did not demonstrate statistically significant improvement. US findings correlated with the physician's palpatory rotational diagnosis (PCC=0.62, P=.004). ICC was greater than 0.9 for intra- and interobserver reliability tests of both US operation and offline image processing.</p><p><strong>Conclusion: </strong>The results of this study demonstrate that US is a feasible method of evaluating the efficacy of OMT. These results show good intra- and interobserver reliability of US acquisition and landmark measurement. Our study suggests that US assessment correlated closely with palpatory diagnosis. Our results also suggest that OMT can significantly improve lumbar rotational asymmetry, but did not improve side-bending asymmetry.</p>","PeriodicalId":47816,"journal":{"name":"JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION","volume":"120 11","pages":"761-769"},"PeriodicalIF":1.1000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.7556/jaoa.2020.127","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7556/jaoa.2020.127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Context: The effectiveness of osteopathic manipulative treatment (OMT) on the lumbar spine has been studied qualitatively, but quantitative measurement of the effects of OMT has not been thoroughly investigated.

Objective: To quantitatively measure the palpated improvements of OMT on the lumbar spine using ultrasonography (US) and correlate palpatory diagnosis with US measurements of lumbar asymmetry.

Methods: From September to November 2018, we recruited 20 adult participants 18 years of age or older. Lumbar somatic dysfunction (SD) was identified via osteopathic palpation. US was then performed on all participants with standard machine settings (frequency, 7 MHz; depth, 7 cm; dynamic range, 60; tissue harmonic imaging; and single-image focus). Longitudinal images of each lumbar transverse process were recorded and saved bilaterally by an experienced radiologist and a medical student. The participant's SD was then managed using OMT, including Still technique, myofascial release, muscle energy technique, high-velocity low-amplitude technique, functional positional release, balanced ligamentous tension, and counterstrain. Following OMT, US was performed again in the same method. Measurements of the saved US images were reviewed using a Digital Imaging and Communications in Medicine viewer. These measurements were obtained by 3 separate observers (J.W., A.K., S.M.), using the same computer software. Statistical analysis included a 2-tailed paired t-test to analyze rotational asymmetry pre- and posttreatment, an intraclass correlation coefficient (ICC) to test intra- and interobserver reliability, and a Pearson correlation coefficient (PCC) to analyze the correlation between US findings and OMT.

Results: The difference in soft tissue thickness before and after OMT was significant (P=.014), indicating improvements in rotational asymmetry. Side-bending asymmetry did not demonstrate statistically significant improvement. US findings correlated with the physician's palpatory rotational diagnosis (PCC=0.62, P=.004). ICC was greater than 0.9 for intra- and interobserver reliability tests of both US operation and offline image processing.

Conclusion: The results of this study demonstrate that US is a feasible method of evaluating the efficacy of OMT. These results show good intra- and interobserver reliability of US acquisition and landmark measurement. Our study suggests that US assessment correlated closely with palpatory diagnosis. Our results also suggest that OMT can significantly improve lumbar rotational asymmetry, but did not improve side-bending asymmetry.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声评价整骨手法治疗腰椎不对称的疗效。
背景:骨科手法治疗(OMT)对腰椎的有效性已经进行了定性研究,但对OMT效果的定量测量尚未进行彻底的研究。目的:定量测量腰椎超声OMT的触诊改善,并将触诊诊断与腰椎不对称的超声测量相关联。方法:2018年9月至11月,我们招募了20名18岁及以上的成人受试者。腰椎躯体功能障碍(SD)通过整骨触诊确诊。然后对所有参与者使用标准机器设置(频率,7 MHz;深度,7厘米;动态范围:60;组织谐波成像;和单图像聚焦)。每个腰椎横突的纵向图像由一位经验丰富的放射科医生和一名医学生记录并保存。然后使用OMT技术,包括Still技术、肌筋膜释放技术、肌肉能量技术、高速低振幅技术、功能性位置释放技术、平衡韧带张力和反张力来管理参与者的SD。在OMT后,再次采用相同的方法进行US。使用医学中的数字成像和通信查看器对保存的美国图像进行测量。这些测量结果是由3个不同的观测者(j.w., a.k., S.M.)使用相同的计算机软件获得的。统计分析包括双尾配对t检验来分析治疗前后的旋转不对称性,类内相关系数(ICC)来检验观察者内部和观察者之间的信度,Pearson相关系数(PCC)来分析US结果与OMT之间的相关性。结果:OMT前后软组织厚度差异有统计学意义(P= 0.014),表明旋转不对称性得到改善。侧弯不对称没有统计学上的显著改善。美国结果与医生的指诊旋转诊断相关(PCC=0.62, P= 0.004)。在美国操作和离线图像处理的观察者内部和观察者之间的信度测试中,ICC大于0.9。结论:本研究结果表明US是一种可行的评价OMT疗效的方法。这些结果表明,美国采集和地标测量具有良好的观察者内部和观察者之间的信度。我们的研究表明美国评估与触诊诊断密切相关。我们的结果还表明,OMT可以显著改善腰椎旋转不对称,但不能改善侧弯不对称。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION
JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION MEDICINE, GENERAL & INTERNAL-
自引率
0.00%
发文量
0
期刊介绍: JAOA—The Journal of the American Osteopathic Association is the official scientific publication of the American Osteopathic Association, as well as the premier scholarly, peer-reviewed publication of the osteopathic medical profession. The JAOA"s mission is to advance medicine through the scholarly publication of peer-reviewed osteopathic medical research. The JAOA"s goals are: 1. To be the authoritative scholarly publication of the osteopathic medical profession 2. To advance the traditional tenets of osteopathic medicine while encouraging the development of emerging concepts relevant to the profession"s distinctiveness
期刊最新文献
A Longitudinal Cohort Study of Youth Mental Health and Substance use Before and During the COVID-19 Pandemic in Ontario, Canada: An Exploratory Analysis. Communication Skills of Grandview/Southview Medical Center General Surgery Residents. Osteopathic Manual Treatment for Pain Severity, Functional Improvement, and Return to Work in Patients With Chronic Pain. Septic Pulmonary Emboli With Feeding Vessel Sign. Sister Mary Joseph Nodule.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1