Iodinated contrast media allergy is rare in patients undergoing sialography.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-09-01 DOI:10.12932/AP-190720-0923
Chen Nadler, Andra Rettman, Nufar Benvenisty, Yaarit Ribak, Alon Y Hershko, Yuval Tal
{"title":"Iodinated contrast media allergy is rare in patients undergoing sialography.","authors":"Chen Nadler,&nbsp;Andra Rettman,&nbsp;Nufar Benvenisty,&nbsp;Yaarit Ribak,&nbsp;Alon Y Hershko,&nbsp;Yuval Tal","doi":"10.12932/AP-190720-0923","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Iodinated contrast media allergy is considered as a strong contra-indication for performing sialography. There is little evidence to support this approach.</p><p><strong>Objective: </strong>To evaluate the rate of iodinated contrast media (ICM) allergy in subjects undergoing sialography and to assess the risk for allergic responses in patients with a previous diagnosis of allergy.</p><p><strong>Methods: </strong>We retrospectively reviewed sialo-CBCT studies performed from 2014 to 2019. During the study period we implemented a protocol for performing sialo-CBCT in patients with a prior diagnosis of allergy: 1) Clinical data were collected from a questionnaire and medical records. 2) No premedication was administered but, instead, oxygen, epinephrine and a resuscitation cart were accessible. 3) Following the procedure, each patient was observed for one hour and contacted by telephone 24 hrs later.</p><p><strong>Results: </strong>No allergic responses were documented in the medical records of 1515 subjects following sialo-CBCT studies, including 13 individuals previously diagnosed with ICM allergy. Investigation of the subgroup with prior allergy disclosed that the range of injected volume was between 2 ml to 6.2 ml per patient and that complete secretion of ICM was detected in 7 of 13 patients. In the remainder of subjects, retention rates of 5-50% were observed.</p><p><strong>Conclusions: </strong>Allergic reactions are exceedingly rare following sialo-CBCT studies regardless of a previous diagnosis of allergy. Pre-medication with corticosteroids and antihistamines is usually not warranted.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12932/AP-190720-0923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 4

Abstract

Background: Iodinated contrast media allergy is considered as a strong contra-indication for performing sialography. There is little evidence to support this approach.

Objective: To evaluate the rate of iodinated contrast media (ICM) allergy in subjects undergoing sialography and to assess the risk for allergic responses in patients with a previous diagnosis of allergy.

Methods: We retrospectively reviewed sialo-CBCT studies performed from 2014 to 2019. During the study period we implemented a protocol for performing sialo-CBCT in patients with a prior diagnosis of allergy: 1) Clinical data were collected from a questionnaire and medical records. 2) No premedication was administered but, instead, oxygen, epinephrine and a resuscitation cart were accessible. 3) Following the procedure, each patient was observed for one hour and contacted by telephone 24 hrs later.

Results: No allergic responses were documented in the medical records of 1515 subjects following sialo-CBCT studies, including 13 individuals previously diagnosed with ICM allergy. Investigation of the subgroup with prior allergy disclosed that the range of injected volume was between 2 ml to 6.2 ml per patient and that complete secretion of ICM was detected in 7 of 13 patients. In the remainder of subjects, retention rates of 5-50% were observed.

Conclusions: Allergic reactions are exceedingly rare following sialo-CBCT studies regardless of a previous diagnosis of allergy. Pre-medication with corticosteroids and antihistamines is usually not warranted.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碘造影剂过敏在接受唾液造影的患者中是罕见的。
背景:碘造影剂过敏被认为是进行唾液酸造影的强烈禁忌。几乎没有证据支持这种做法。目的:评估唾液造影受试者碘造影剂(ICM)过敏的发生率,并评估既往诊断为过敏的患者发生过敏反应的风险。方法:我们回顾性回顾了2014年至2019年进行的唾液CBCT研究。在研究期间,我们实施了一项对既往诊断为过敏的患者进行唾液CBCT的方案:1)从问卷和医疗记录中收集临床数据。2) 没有进行药物治疗,但可以使用氧气、肾上腺素和复苏车。3) 手术后,对每位患者进行一小时的观察,24小时后通过电话联系。结果:1515名受试者在唾液CBCT研究后的医疗记录中没有记录过敏反应,其中包括13名先前诊断为ICM过敏的受试者。对既往过敏亚组的调查显示,每位患者的注射量范围在2毫升至6.2毫升之间,13名患者中有7名检测到ICM完全分泌。在其余受试者中,观察到5-50%的保留率。结论:唾液CBCT研究后,无论先前是否诊断为过敏,过敏反应都极为罕见。通常不需要使用皮质类固醇和抗组胺药进行药物治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1