Non-Invasive Methods for PWV Measurement in Blood Vessel Stiffness Assessment

IF 17.2 1区 工程技术 Q1 ENGINEERING, BIOMEDICAL IEEE Reviews in Biomedical Engineering Pub Date : 2021-06-24 DOI:10.1109/RBME.2021.3092208
Giorgia Fiori;Fabio Fuiano;Andrea Scorza;Silvia Conforto;Salvatore Andrea Sciuto
{"title":"Non-Invasive Methods for PWV Measurement in Blood Vessel Stiffness Assessment","authors":"Giorgia Fiori;Fabio Fuiano;Andrea Scorza;Silvia Conforto;Salvatore Andrea Sciuto","doi":"10.1109/RBME.2021.3092208","DOIUrl":null,"url":null,"abstract":"In recent years, statistical studies highlighted an increasing incidence of cardiovascular diseases (CVD) which reflected on additional costs on the healthcare systems worldwide. Pulse wave velocity (PWV) measurement is commonly considered a CVD predictor factor as well as a marker of Arterial Stiffness (AS) since it is closely related to the mechanical characteristics of the arterial wall. An increase in PWV is due to a more rigid arterial system. Because of the prevalence of the elastic component, in young people the PWV is lower than in the elderly. Nowadays, invasive and non-invasive methods for PWV assessment are employed: there is an increasing attention in the development of non-invasive devices which mostly perform a regional PWV measurement (over a long arterial portion) rather than local (over a short arterial portion). The accepted gold-standard for non-invasive AS measurement is the carotid-femoral PWV used to evaluate the arterial damage, the corresponding cardiovascular risk and to adapt the proper therapy. This review article considers the main commercially available devices underlining their operating principles in terms of sensors, execution mode, pulse waveforms acquired, site of measurement, distance and time estimation methods, as well as their main limitations in clinical practice.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"15 ","pages":"169-183"},"PeriodicalIF":17.2000,"publicationDate":"2021-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9464721/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 16

Abstract

In recent years, statistical studies highlighted an increasing incidence of cardiovascular diseases (CVD) which reflected on additional costs on the healthcare systems worldwide. Pulse wave velocity (PWV) measurement is commonly considered a CVD predictor factor as well as a marker of Arterial Stiffness (AS) since it is closely related to the mechanical characteristics of the arterial wall. An increase in PWV is due to a more rigid arterial system. Because of the prevalence of the elastic component, in young people the PWV is lower than in the elderly. Nowadays, invasive and non-invasive methods for PWV assessment are employed: there is an increasing attention in the development of non-invasive devices which mostly perform a regional PWV measurement (over a long arterial portion) rather than local (over a short arterial portion). The accepted gold-standard for non-invasive AS measurement is the carotid-femoral PWV used to evaluate the arterial damage, the corresponding cardiovascular risk and to adapt the proper therapy. This review article considers the main commercially available devices underlining their operating principles in terms of sensors, execution mode, pulse waveforms acquired, site of measurement, distance and time estimation methods, as well as their main limitations in clinical practice.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PWV无创测量方法在血管硬度评估中的应用
近年来,统计研究强调了心血管疾病(CVD)发病率的增加,这反映了全球医疗系统的额外成本。脉搏波速度(PWV)测量通常被认为是CVD的预测因素,也是动脉硬度(as)的标志,因为它与动脉壁的机械特性密切相关。PWV的增加是由于动脉系统更加坚硬。由于弹性成分的普遍性,年轻人的PWV低于老年人。如今,PWV评估采用了有创和无创方法:无创设备的开发越来越受到关注,这些设备主要进行区域PWV测量(在长动脉部分),而不是局部测量(在短动脉部分)。公认的非侵入性AS测量的金标准是颈动脉-股骨PWV,用于评估动脉损伤、相应的心血管风险和适应适当的治疗。这篇综述文章考虑了主要的商用设备,强调了它们在传感器、执行模式、采集的脉冲波形、测量地点、距离和时间估计方法方面的工作原理,以及它们在临床实践中的主要局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Reviews in Biomedical Engineering
IEEE Reviews in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
31.70
自引率
0.60%
发文量
93
期刊介绍: IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.
期刊最新文献
Foundation Model for Advancing Healthcare: Challenges, Opportunities and Future Directions. A Manual for Genome and Transcriptome Engineering. Artificial General Intelligence for Medical Imaging Analysis. A Survey of Few-Shot Learning for Biomedical Time Series. The Physiome Project and Digital Twins.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1