{"title":"Effect of Surface Moisture on Bur-cut Dentin on Bonding of HEMA-free and HEMA-containing Universal Adhesives with or without Methacrylamide Monomer.","authors":"Nooruldeen Ali Saeed, Antonin Tichy, Yusuke Kuno, Keiichi Hosaka, Junji Tagami, Masatoshi Nakajima","doi":"10.3290/j.jad.b1650121","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The effect of surface moisture on bur-cut dentin on the microtensile bond strength (μTBS) of universal adhesives with various contents of 2-hydroxyethyl methacrylate (HEMA) and methacrylamide monomers was evaluated.</p><p><strong>Materials and methods: </strong>Flat mid-coronal dentin surfaces of human molars were exposed, and a standardized smear layer was prepared using a fine-grit diamond bur. The surfaces were either left wet or air dried for 10 s before bonding with Clearfil Universal Bond Quick (UBQ), experimental UBQ without an amide monomer (UBQexp), Scotchbond Universal (SBU), Prime&Bond Universal (PBU), or BeautiBond Universal (BBU). The specimens were built up with resin composite, sectioned into sticks and subjected to the μTBS test after 24 h or 10,000 thermal cycles. The μTBS data were analyzed using three-way ANOVA followed by pairwise comparisons with Bonferroni's correction (α = 0.05).</p><p><strong>Results: </strong>The level of dentin moisture did not significantly affect μTBS of UBQ and BBU (p > 0.05). HEMA-containing UBQ, UBQexp, and SBU exhibited higher μTBS to dry dentin, while HEMA-free PBU and BBU showed higher μTBS to wet dentin. Thermocycling significantly decreased the μTBS of UBQexp (p < 0.01) and BBU (p < 0.001) irrespective of dentin moisture level, while SBU was significantly affected only on dry dentin (p < 0.001). Thermocycling had no significant effect on UBQ and PBU containing methacrylamide monomers (p > 0.05).</p><p><strong>Conclusion: </strong>Dry surfaces enabled obtaining optimal bonding for HEMA-containing adhesives to bur-cut dentin, while wet surfaces enabled optimal bonding for HEMA-free adhesives. Methacrylamide monomers could contribute to the improvement of the initial and long-term bonding performance of universal adhesives to bur-cut dentin.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"23 4","pages":"327-334"},"PeriodicalIF":2.5000,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Adhesive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b1650121","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2
Abstract
Purpose: The effect of surface moisture on bur-cut dentin on the microtensile bond strength (μTBS) of universal adhesives with various contents of 2-hydroxyethyl methacrylate (HEMA) and methacrylamide monomers was evaluated.
Materials and methods: Flat mid-coronal dentin surfaces of human molars were exposed, and a standardized smear layer was prepared using a fine-grit diamond bur. The surfaces were either left wet or air dried for 10 s before bonding with Clearfil Universal Bond Quick (UBQ), experimental UBQ without an amide monomer (UBQexp), Scotchbond Universal (SBU), Prime&Bond Universal (PBU), or BeautiBond Universal (BBU). The specimens were built up with resin composite, sectioned into sticks and subjected to the μTBS test after 24 h or 10,000 thermal cycles. The μTBS data were analyzed using three-way ANOVA followed by pairwise comparisons with Bonferroni's correction (α = 0.05).
Results: The level of dentin moisture did not significantly affect μTBS of UBQ and BBU (p > 0.05). HEMA-containing UBQ, UBQexp, and SBU exhibited higher μTBS to dry dentin, while HEMA-free PBU and BBU showed higher μTBS to wet dentin. Thermocycling significantly decreased the μTBS of UBQexp (p < 0.01) and BBU (p < 0.001) irrespective of dentin moisture level, while SBU was significantly affected only on dry dentin (p < 0.001). Thermocycling had no significant effect on UBQ and PBU containing methacrylamide monomers (p > 0.05).
Conclusion: Dry surfaces enabled obtaining optimal bonding for HEMA-containing adhesives to bur-cut dentin, while wet surfaces enabled optimal bonding for HEMA-free adhesives. Methacrylamide monomers could contribute to the improvement of the initial and long-term bonding performance of universal adhesives to bur-cut dentin.
期刊介绍:
New materials and applications for adhesion are profoundly changing the way dentistry is delivered. Bonding techniques, which have long been restricted to the tooth hard tissues, enamel, and dentin, have obvious applications in operative and preventive dentistry, as well as in esthetic and pediatric dentistry, prosthodontics, and orthodontics. The current development of adhesive techniques for soft tissues and slow-releasing agents will expand applications to include periodontics and oral surgery. Scientifically sound, peer-reviewed articles explore the latest innovations in these emerging fields.