Global Thrombosis Test: Occlusion by Coagulation or SIPA?

Viviana Clavería, Patricia J Yang, Michael T Griffin, David N Ku
{"title":"Global Thrombosis Test: Occlusion by Coagulation or SIPA?","authors":"Viviana Clavería,&nbsp;Patricia J Yang,&nbsp;Michael T Griffin,&nbsp;David N Ku","doi":"10.1055/s-0041-1732341","DOIUrl":null,"url":null,"abstract":"<p><p>The global thrombosis test (GTT) is a point of care device that tests thrombotic and thrombolytic status. The device exposes whole blood flow to a combination of both high and low shear stress past and between ball bearings potentially causing thrombin and fibrin formation. The question arises as to whether thrombosis in the GTT is dominated by coagulation-triggered red clot or high shear-induced white clot. We investigated the nature of the thrombus formed in the GTT, the device efficacy, human factors use, and limitations. The GTT formed clots that were histologically fibrin-rich with trapped red blood cells. The occlusion time (OT) was more consistent with coagulation than high shear white clot and was strongly lengthened by heparin and citrate, two common anticoagulants. The clot was lysed by tissue plasminogen activator (tPA), also consistent with a fibrin-rich red clot. Changing the bead to a collagen-coated surface and eliminating the low shear zone between the beads induced a rapid OT consistent with a platelet-rich thrombus that was relatively resistant to heparin or tPA. The evidence points to the GTT as occluding primarily due to fibrin-rich red clot from coagulation rather than high shear platelet aggregation and occlusion associated with arterial thrombosis.</p>","PeriodicalId":22238,"journal":{"name":"TH Open: Companion Journal to Thrombosis and Haemostasis","volume":"5 3","pages":"e400-e410"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450046/pdf/","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TH Open: Companion Journal to Thrombosis and Haemostasis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1732341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The global thrombosis test (GTT) is a point of care device that tests thrombotic and thrombolytic status. The device exposes whole blood flow to a combination of both high and low shear stress past and between ball bearings potentially causing thrombin and fibrin formation. The question arises as to whether thrombosis in the GTT is dominated by coagulation-triggered red clot or high shear-induced white clot. We investigated the nature of the thrombus formed in the GTT, the device efficacy, human factors use, and limitations. The GTT formed clots that were histologically fibrin-rich with trapped red blood cells. The occlusion time (OT) was more consistent with coagulation than high shear white clot and was strongly lengthened by heparin and citrate, two common anticoagulants. The clot was lysed by tissue plasminogen activator (tPA), also consistent with a fibrin-rich red clot. Changing the bead to a collagen-coated surface and eliminating the low shear zone between the beads induced a rapid OT consistent with a platelet-rich thrombus that was relatively resistant to heparin or tPA. The evidence points to the GTT as occluding primarily due to fibrin-rich red clot from coagulation rather than high shear platelet aggregation and occlusion associated with arterial thrombosis.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全球血栓测试:凝血阻断还是SIPA阻断?
全球血栓形成测试(GTT)是一种检测血栓形成和溶栓状态的护理点设备。该装置将全血流暴露在经过滚珠轴承和滚珠轴承之间的高剪切应力和低剪切应力的组合下,可能导致凝血酶和纤维蛋白的形成。GTT中的血栓形成是由凝血触发的红血块还是由高剪切诱导的白血块主导的问题出现了。我们研究了GTT中形成血栓的性质、装置的疗效、人为因素的使用和局限性。GTT形成的凝块在组织学上富含纤维蛋白,含有被捕获的红细胞。与高剪切白色凝块相比,闭塞时间(OT)更符合凝血,肝素和柠檬酸盐这两种常见的抗凝剂大大延长了闭塞时间。凝块被组织纤溶酶原激活剂(tPA)溶解,也与富含纤维蛋白的红色凝块一致。将珠粒改为胶原涂层表面并消除珠粒之间的低剪切区诱导了快速OT,其与对肝素或tPA具有相对抗性的富含血小板的血栓一致。有证据表明,GTT闭塞主要是由于凝血产生的富含纤维蛋白的红色凝块,而不是与动脉血栓形成相关的高剪切血小板聚集和闭塞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Management of Urgent Bleeding in Patients with Hemophilia A: Focus on the Use of Emicizumab Disease Burden, Clinical Outcomes, and Quality of Life in People with Hemophilia A without Inhibitors in Europe: Analyses from CHESS II/CHESS PAEDs TH Open Continues to Highlight the State-of-the-Art on Thrombosis and Hemostasis with a Renewed Editorial Board The Effect of Rituximab on Antiphospholipid Titers in Patients with Antiphospholipid Syndrome. Potential for a Virtual Care Model in the Perioperative Management of Anticoagulant Therapy: A 5-Year Retrospective Clinic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1