Modified cerclage wiring in comminuted transolecranon fracture-dislocations of the elbow.

IF 1.4 Q3 EMERGENCY MEDICINE International Journal of Burns and Trauma Pub Date : 2021-12-15 eCollection Date: 2021-01-01
Praveen Sodavarapu, Deepak Kumar, Shahnawaz Khan, Karmesh Kumar, Aman Hooda, Aditya Vardhan Guduru
{"title":"Modified cerclage wiring in comminuted transolecranon fracture-dislocations of the elbow.","authors":"Praveen Sodavarapu,&nbsp;Deepak Kumar,&nbsp;Shahnawaz Khan,&nbsp;Karmesh Kumar,&nbsp;Aman Hooda,&nbsp;Aditya Vardhan Guduru","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Transolecranon fracture-dislocations are a result of high-energy trauma, caused due to axial loading of the flexed forearm, with associated anterior dislocation of the ulna with respect to the distal humerus. The usual management of these comminuted and unstable fractures is by using locking compression plates via the dorsal approach. However, plating in cases of poor soft tissue coverage and open wounds can be precarious. In this study, we aimed to evaluate outcomes of cerclage wiring in the management of comminuted trans-olecranon fracture-dislocations in such scenario. A total of seven patients diagnosed with trans-olecranon fracture-dislocation with poor soft tissue coverage who underwent cerclage wiring were included in the study. The aim was to realign the proximal portion of the olecranon to the trochlea and restore the normal ulnohumeral articular relationships accomplished by the anatomical reconstruction of the greater sigmoid notch. Reconstruction of the proximal ulna was started from the distal to the proximal direction so as to convert an unstable fracture into a stable one. After the reduction of the proximal fragment, two long 2 mm K wires were inserted from the tip of the olecranon into the intramedullary canal (with at least 1 wire passed subchondrally), and later cerclage was done. Postoperatively the patient was immobilized for a duration of two weeks and was later started on active assisted mobilization of the elbow. All patients showed fair-to-excellent outcome on the Mayo elbow performance score (MEPS) at the final follow-up (five patients had an excellent score, one had a good score, and one had a fair score). At the final follow-up, the mean extension, flexion, pronation and supination were -20, 117.14, 82.85 and 78.57 degrees respectively. The key components of such management are the restoration of articular congruity, including continuity of the sigmoid cavity, ulnar length, and early initiation of active elbow movements to avoid joint stiffness. Optimal functional results can be achieved with K wire and cerclage when a stable anatomic reconstruction is accomplished, as a feasible alternative to plating.</p>","PeriodicalId":45488,"journal":{"name":"International Journal of Burns and Trauma","volume":"11 6","pages":"456-462"},"PeriodicalIF":1.4000,"publicationDate":"2021-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784742/pdf/ijbt0011-0456.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Burns and Trauma","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Transolecranon fracture-dislocations are a result of high-energy trauma, caused due to axial loading of the flexed forearm, with associated anterior dislocation of the ulna with respect to the distal humerus. The usual management of these comminuted and unstable fractures is by using locking compression plates via the dorsal approach. However, plating in cases of poor soft tissue coverage and open wounds can be precarious. In this study, we aimed to evaluate outcomes of cerclage wiring in the management of comminuted trans-olecranon fracture-dislocations in such scenario. A total of seven patients diagnosed with trans-olecranon fracture-dislocation with poor soft tissue coverage who underwent cerclage wiring were included in the study. The aim was to realign the proximal portion of the olecranon to the trochlea and restore the normal ulnohumeral articular relationships accomplished by the anatomical reconstruction of the greater sigmoid notch. Reconstruction of the proximal ulna was started from the distal to the proximal direction so as to convert an unstable fracture into a stable one. After the reduction of the proximal fragment, two long 2 mm K wires were inserted from the tip of the olecranon into the intramedullary canal (with at least 1 wire passed subchondrally), and later cerclage was done. Postoperatively the patient was immobilized for a duration of two weeks and was later started on active assisted mobilization of the elbow. All patients showed fair-to-excellent outcome on the Mayo elbow performance score (MEPS) at the final follow-up (five patients had an excellent score, one had a good score, and one had a fair score). At the final follow-up, the mean extension, flexion, pronation and supination were -20, 117.14, 82.85 and 78.57 degrees respectively. The key components of such management are the restoration of articular congruity, including continuity of the sigmoid cavity, ulnar length, and early initiation of active elbow movements to avoid joint stiffness. Optimal functional results can be achieved with K wire and cerclage when a stable anatomic reconstruction is accomplished, as a feasible alternative to plating.

Abstract Image

Abstract Image

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改良环系钢丝治疗肘关节鹰嘴粉碎性骨折脱位。
经鹰口骨折脱位是由于前臂屈曲的轴向负荷引起的高能创伤,并伴有肱骨远端尺骨前脱位。这些粉碎性和不稳定骨折的通常治疗方法是通过背侧入路使用锁定加压钢板。然而,在软组织覆盖不良和开放性伤口的情况下,电镀可能是不稳定的。在这项研究中,我们的目的是评估在这种情况下,环扣钢丝治疗粉碎性鹰嘴骨折脱位的效果。共有7例经诊断为鹰嘴骨折脱位且软组织覆盖不良的患者接受了环扎钢丝治疗。目的是重新调整鹰嘴近端与滑车的关系,并通过乙状突大切迹的解剖重建来恢复正常的尺骨关节关系。从远端到近端开始重建近端尺骨,以便将不稳定骨折转化为稳定骨折。近端碎片复位后,从鹰嘴尖端将两根2mm长的K针插入髓内管(至少有一根针通过软骨下),然后进行环扎术。术后患者固定两周,随后开始主动辅助肘关节活动。在最后的随访中,所有患者的梅奥肘关节功能评分(MEPS)均显示出一般至优异的结果(5名患者评分为优异,1名评分为良好,1名评分为一般)。在最后随访时,平均伸、屈、旋前和旋后分别为-20度、117.14度、82.85度和78.57度。这种治疗的关键组成部分是关节一致性的恢复,包括乙状骨腔的连续性,尺骨长度,以及早期开始主动肘关节运动以避免关节僵硬。当完成稳定的解剖重建时,使用K线和环夹可以获得最佳的功能结果,作为电镀的可行替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
12.50%
发文量
0
期刊最新文献
Autologous non-vascularized fibula with compression plating in the management of aseptic complex non-union of long bones. Combined awake videolaryngo-bronchoscopy intubation with HFNC preoxygenation for predicted difficult airway in a patient with post-burn mentosternal scar contracture. Comparative outcome of ultrasound guided vs. fluoroscopy guided hydrodilatation in adhesive capsulitis: a prospective study. Evaluation of pain associated with the application of burn dressings. Malignant peripheral nerve sheath tumour presenting as pathological fracture of proximal femur in neurofibromatosis type-1: a case report with brief literature search.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1