A highly miniaturized antenna with wider band for biomedical applications.

IF 1.5 4区 生物学 Q3 BIOLOGY Electromagnetic Biology and Medicine Pub Date : 2022-01-02 Epub Date: 2021-11-04 DOI:10.1080/15368378.2021.1993892
Doondi Kumar Janapala, M Nesasudha
{"title":"A highly miniaturized antenna with wider band for biomedical applications.","authors":"Doondi Kumar Janapala,&nbsp;M Nesasudha","doi":"10.1080/15368378.2021.1993892","DOIUrl":null,"url":null,"abstract":"<p><p>A highly miniaturized planar monopole antenna is presented for biomedical applications. The proposed antenna utilizes polydimethylsiloxane (PDMS) with dielectric constant 2.7 and loss tangent 0.0314 with thickness 0.3 mm as substrate and with thickness 0.2 mm as superstrate. A copper foil of 0.03 mm thickness is used for radiating elements. The proposed structure contains a unique structure, made of loop-based structure with three rectangular-shaped stubs are added to tune the operating frequency to 5.8 GHz and to improve the reflection coefficient. The incorporation of stubs achieved the intended frequency of operation, utilization of the loop-based structure for designing the antenna achieved high miniaturization. The proposed antenna is analyzed under various conditions like under skin, muscle, stomach, small intestine,, colon etc., and comparative analysis is presented with the help of reflection coefficient, radiation patterns and specific absorption rate (SAR). SAR is evaluated over a volume of 1 g tissue as per the standards of Federal Communications Commission (FCC). SAR value of the antenna is below 1.6 W/kg for input power 1.9 mW. The simulated analysis showed that the designed antenna is suitable for both implantable and endoscopic applications. Moreover the simulated and measured analysis for reflection coefficient of the proposed antenna showed good agreement.</p>","PeriodicalId":50544,"journal":{"name":"Electromagnetic Biology and Medicine","volume":"41 1","pages":"35-43"},"PeriodicalIF":1.5000,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electromagnetic Biology and Medicine","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1080/15368378.2021.1993892","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/11/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

A highly miniaturized planar monopole antenna is presented for biomedical applications. The proposed antenna utilizes polydimethylsiloxane (PDMS) with dielectric constant 2.7 and loss tangent 0.0314 with thickness 0.3 mm as substrate and with thickness 0.2 mm as superstrate. A copper foil of 0.03 mm thickness is used for radiating elements. The proposed structure contains a unique structure, made of loop-based structure with three rectangular-shaped stubs are added to tune the operating frequency to 5.8 GHz and to improve the reflection coefficient. The incorporation of stubs achieved the intended frequency of operation, utilization of the loop-based structure for designing the antenna achieved high miniaturization. The proposed antenna is analyzed under various conditions like under skin, muscle, stomach, small intestine,, colon etc., and comparative analysis is presented with the help of reflection coefficient, radiation patterns and specific absorption rate (SAR). SAR is evaluated over a volume of 1 g tissue as per the standards of Federal Communications Commission (FCC). SAR value of the antenna is below 1.6 W/kg for input power 1.9 mW. The simulated analysis showed that the designed antenna is suitable for both implantable and endoscopic applications. Moreover the simulated and measured analysis for reflection coefficient of the proposed antenna showed good agreement.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种高度小型化、宽频带的生物医学应用天线。
提出了一种高度小型化的平面单极天线。该天线采用介电常数为2.7、损耗正切为0.0314的聚二甲基硅氧烷(PDMS)作为衬底,衬底厚度为0.3 mm,衬底厚度为0.2 mm。0.03毫米厚度的铜箔用于辐射元件。该结构采用了一种独特的环形结构,通过增加三个矩形短桩将工作频率调至5.8 GHz,从而提高了反射系数。存根的结合实现了预期的工作频率,利用基于环路的结构设计天线实现了高度小型化。在皮肤、肌肉、胃、小肠、结肠等不同条件下对天线进行了分析,并利用反射系数、辐射方向图和比吸收率(SAR)进行了对比分析。根据联邦通信委员会(FCC)的标准,SAR在1g组织体积上进行评估。当输入功率为1.9 mW时,天线的SAR值低于1.6 W/kg。仿真分析表明,所设计的天线既适合植入应用,也适合内窥镜应用。对天线反射系数的仿真分析与实测分析结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
11.80%
发文量
33
审稿时长
>12 weeks
期刊介绍: Aims & Scope: Electromagnetic Biology and Medicine, publishes peer-reviewed research articles on the biological effects and medical applications of non-ionizing electromagnetic fields (from extremely-low frequency to radiofrequency). Topic examples include in vitro and in vivo studies, epidemiological investigation, mechanism and mode of interaction between non-ionizing electromagnetic fields and biological systems. In addition to publishing original articles, the journal also publishes meeting summaries and reports, and reviews on selected topics.
期刊最新文献
Radiofrequency electromagnetic fields in Alzheimer's therapy: emerging evidence and future prospects. Effects of exposure to nearby mobile phone base stations and mobile phone usage on human blood parameters. When biology meets polarity: Toward a unified framework for sex-dependent responses to magnetic polarity in living systems. Biological responses to 30 mT static magnetic field in young and 36-month-old rats. Lawn bowling and potential interference of a cardiovascular implantable electronic device (CIED): case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1