Performance evaluation of the new Chemiluminescence Immunoassay CL-1200i Thyroid Panel.

Q2 Health Professions Journal of immunoassay & immunochemistry Pub Date : 2022-05-04 Epub Date: 2021-12-18 DOI:10.1080/15321819.2021.2017301
Eleonora Nicolai, Marzia Nuccetelli, Serena Sarubbi, Valerio Basile, Marco Alfonso Perrone, Alessandro Terrinoni, Marilena Minieri, Massimo Pieri, Sergio Bernardini
{"title":"Performance evaluation of the new Chemiluminescence Immunoassay CL-1200i Thyroid Panel.","authors":"Eleonora Nicolai,&nbsp;Marzia Nuccetelli,&nbsp;Serena Sarubbi,&nbsp;Valerio Basile,&nbsp;Marco Alfonso Perrone,&nbsp;Alessandro Terrinoni,&nbsp;Marilena Minieri,&nbsp;Massimo Pieri,&nbsp;Sergio Bernardini","doi":"10.1080/15321819.2021.2017301","DOIUrl":null,"url":null,"abstract":"<p><p>Aim of this work was to verify the analytical performance of thyroid panel tests measured by chemiluminescence immunoassay (CLIA) CL-1200i and to validate its efficacy as laboratory test for thyroid disorder.Serum samples were obtained by standard centrifugation, thawed and assayed in a blinded fashion, and in a single batch. This study compares the values of thyroid panel tests measured by Mindray CL-1200i chemiluminescent system to the Abbott platforms for TSH, FT3, FT4, and Beckman Coulter for Tg, TgAb, and TPOAb on patient serum samples. A total of 180 randomly selected patients including both hospitalized and ambulatory patients from the Policlinico Tor Vergata (PTV) of the University of Rome Tor Vergata were used. In all analyses performed, the thyroid panel tests of the Mindray platform showed discriminative ability to quantitatively assess the analyte involved in thyroid disease and disorder. This study verified that Mindray CL-1200i chemiluminescent system thyroid panel tests is a valid method for obtaining a quantitative analysis of thyroid disorders. It showed high diagnostic efficiency and could represent a valid tool with a potential reduction in time and workload for the diagnosis.</p>","PeriodicalId":15990,"journal":{"name":"Journal of immunoassay & immunochemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunoassay & immunochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15321819.2021.2017301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/18 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 1

Abstract

Aim of this work was to verify the analytical performance of thyroid panel tests measured by chemiluminescence immunoassay (CLIA) CL-1200i and to validate its efficacy as laboratory test for thyroid disorder.Serum samples were obtained by standard centrifugation, thawed and assayed in a blinded fashion, and in a single batch. This study compares the values of thyroid panel tests measured by Mindray CL-1200i chemiluminescent system to the Abbott platforms for TSH, FT3, FT4, and Beckman Coulter for Tg, TgAb, and TPOAb on patient serum samples. A total of 180 randomly selected patients including both hospitalized and ambulatory patients from the Policlinico Tor Vergata (PTV) of the University of Rome Tor Vergata were used. In all analyses performed, the thyroid panel tests of the Mindray platform showed discriminative ability to quantitatively assess the analyte involved in thyroid disease and disorder. This study verified that Mindray CL-1200i chemiluminescent system thyroid panel tests is a valid method for obtaining a quantitative analysis of thyroid disorders. It showed high diagnostic efficiency and could represent a valid tool with a potential reduction in time and workload for the diagnosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型化学发光免疫分析法CL-1200i甲状腺检测组的性能评价。
本工作的目的是验证化学发光免疫分析法(CLIA) CL-1200i测定甲状腺组试验的分析性能,并验证其作为甲状腺疾病实验室检测的有效性。血清样品通过标准离心、解冻和单批盲法测定获得。本研究比较了迈瑞CL-1200i化学发光系统与雅培平台测定患者血清样本中TSH、FT3、FT4和Beckman Coulter测定Tg、TgAb和TPOAb的结果。随机选择罗马大学Vergata医院(PTV)住院和非住院患者180例。在进行的所有分析中,迈瑞平台的甲状腺面板测试显示出定量评估与甲状腺疾病和紊乱有关的分析物的判别能力。本研究证实迈瑞CL-1200i化学发光系统甲状腺面板试验是获得甲状腺疾病定量分析的有效方法。它显示出很高的诊断效率,可以代表一种有效的工具,可以减少诊断的时间和工作量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
38
审稿时长
>12 weeks
期刊介绍: The Journal of Immunoassay & Immunochemistry is an international forum for rapid dissemination of research results and methodologies dealing with all aspects of immunoassay and immunochemistry, as well as selected aspects of immunology. They include receptor assay, enzyme-linked immunosorbent assay (ELISA) in all of its embodiments, ligand-based assays, biological markers of ligand-receptor interaction, in vivo and in vitro diagnostic reagents and techniques, diagnosis of AIDS, point-of-care testing, clinical immunology, antibody isolation and purification, and others.
期刊最新文献
Emerging therapies and innovations in vitiligo management: a comprehensive review. Molecular dynamics simulation and purification of chimeric L1/L2 protein from human papillomavirus type 52 expressed in Escherichia coli BL21 (DE3). Biochemical study of ZNF76 rs10947540 and SCUBE3 rs1888822 single nucleotide polymorphisms in the Egyptian patients with systemic lupus Erythematosus. Correction. The value of immunohistochemical expression of SOX9 and CD34 in alopecia areata.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1