Non-contrast-enhanced magnetic resonance imaging can be used to assess renal cortical and medullary volumes-A validation study.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Acta radiologica open Pub Date : 2022-01-21 eCollection Date: 2022-01-01 DOI:10.1177/20584601211072281
Jonas Liefke, Katarina Steding-Ehrenborg, Daniel Asgeirsson, David Nordlund, Sascha Kopic, Eva Morsing, Erik Hedström
{"title":"Non-contrast-enhanced magnetic resonance imaging can be used to assess renal cortical and medullary volumes-A validation study.","authors":"Jonas Liefke,&nbsp;Katarina Steding-Ehrenborg,&nbsp;Daniel Asgeirsson,&nbsp;David Nordlund,&nbsp;Sascha Kopic,&nbsp;Eva Morsing,&nbsp;Erik Hedström","doi":"10.1177/20584601211072281","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Magnetic resonance imaging (MRI) biomarkers can diagnose and prognosticate kidney disease. Renal volume validation studies are however scarce, and measurements are limited by use of contrast agent or advanced post-processing.</p><p><strong>Purpose: </strong>To validate a widely available non-contrast-enhanced MRI method for quantification of renal cortical and medullary volumes in pigs; investigate observer variability of cortical and medullary volumes in humans; and present reference values for renal cortical and medullary volumes in adolescents.</p><p><strong>Materials and methods: </strong>Cortical and medullary volumes were quantified from transaxial in-vivo water-excited MR images in six pigs and 15 healthy adolescents (13-16years). Pig kidneys were excised, and renal cortex and medulla were separately quantified by the water displacement method. Both limits of agreement by the Bland-Altman method and reference ranges are presented as 2.5-97.5 percentiles.</p><p><strong>Results: </strong>Agreement between MRI and ex-vivo quantification were -7 mL (-10-0 mL) for total parenchyma, -4 mL (-9-3 mL) for cortex, and -2 mL (-7-2 mL) for medulla. Intraobserver variability for pig and human kidneys were <5% for total parenchyma, cortex, and medulla. Interobserver variability for both pig and human kidneys were ≤4% for total parenchyma and cortex, and 6% and 12% for medulla. Reference ranges indexed for body surface area and sex were 54-103 mL/m<sup>2</sup> (boys) and 56-103 mL/m<sup>2</sup> (girls) for total parenchyma, 39-62 mL/m<sup>2</sup> and 36-68 mL/m<sup>2</sup> for cortex, and 16-45 mL/m<sup>2</sup> and 17-42 mL/m<sup>2</sup> for medulla.</p><p><strong>Conclusion: </strong>The proposed widely available non-contrast-enhanced MRI method can quantify cortical and medullary renal volumes and can be directly implemented clinically.</p>","PeriodicalId":72063,"journal":{"name":"Acta radiologica open","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2022-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796087/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20584601211072281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Magnetic resonance imaging (MRI) biomarkers can diagnose and prognosticate kidney disease. Renal volume validation studies are however scarce, and measurements are limited by use of contrast agent or advanced post-processing.

Purpose: To validate a widely available non-contrast-enhanced MRI method for quantification of renal cortical and medullary volumes in pigs; investigate observer variability of cortical and medullary volumes in humans; and present reference values for renal cortical and medullary volumes in adolescents.

Materials and methods: Cortical and medullary volumes were quantified from transaxial in-vivo water-excited MR images in six pigs and 15 healthy adolescents (13-16years). Pig kidneys were excised, and renal cortex and medulla were separately quantified by the water displacement method. Both limits of agreement by the Bland-Altman method and reference ranges are presented as 2.5-97.5 percentiles.

Results: Agreement between MRI and ex-vivo quantification were -7 mL (-10-0 mL) for total parenchyma, -4 mL (-9-3 mL) for cortex, and -2 mL (-7-2 mL) for medulla. Intraobserver variability for pig and human kidneys were <5% for total parenchyma, cortex, and medulla. Interobserver variability for both pig and human kidneys were ≤4% for total parenchyma and cortex, and 6% and 12% for medulla. Reference ranges indexed for body surface area and sex were 54-103 mL/m2 (boys) and 56-103 mL/m2 (girls) for total parenchyma, 39-62 mL/m2 and 36-68 mL/m2 for cortex, and 16-45 mL/m2 and 17-42 mL/m2 for medulla.

Conclusion: The proposed widely available non-contrast-enhanced MRI method can quantify cortical and medullary renal volumes and can be directly implemented clinically.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非对比增强磁共振成像可用于评估肾皮质和髓质体积-一项验证研究。
背景:磁共振成像(MRI)生物标志物可以诊断和预测肾脏疾病。然而,肾容量验证研究很少,测量受到使用造影剂或先进后处理的限制。目的:验证一种广泛使用的非对比增强MRI定量猪肾皮质和肾髓体积的方法;研究人类皮层和髓质体积的观察变异性;并提出了青少年肾皮质和肾髓体积的参考值。材料和方法:对6头猪和15名健康青少年(13-16岁)的体内经轴水激磁共振成像进行皮质和髓质体积量化。取猪肾,分别用水置换法定量肾皮质和肾髓质。Bland-Altman方法的一致性界限和参考范围均为2.5-97.5个百分点。结果:MRI与离体定量的一致性为:全实质-7 mL (-10-0 mL),皮层-4 mL (-9-3 mL),髓质-2 mL (-7-2 mL)。猪和人肾脏的观察内变异性为:总实质为2 mL/m2(男孩)和56-103 mL/m2(女孩),皮质为39-62 mL/m2和36-68 mL/m2,髓质为16-45 mL/m2和17-42 mL/m2。结论:本文提出的非对比增强MRI方法可量化肾皮质和肾髓质体积,可直接应用于临床。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Differential diagnosis between low-risk and high-risk thymoma: Comparison of diagnostic performance of radiologists with and without deep learning model. Computed tomography patterns and clinical outcomes of radiation pneumonitis in non-small-cell lung cancer patients. Cranial nerves bridging the middle ear and cerebellum causing cerebellar peduncle abscess: A case report. Invasive trigeminal ganglioneuroma: A case report and review of the literature. A case of primary osteosarcoma in the occipital bone: A relatively common tumor in an uncommon location.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1