Evan B Garden, Osama Al-Alao, Shirin Razdan, Gregory R Mullen, Sander Florman, Michael A Palese
{"title":"Robotic Single-Port Donor Nephrectomy with the da Vinci SP® Surgical System.","authors":"Evan B Garden, Osama Al-Alao, Shirin Razdan, Gregory R Mullen, Sander Florman, Michael A Palese","doi":"10.4293/JSLS.2021.00062","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The da Vinci SP® Surgical System received U.S. Food and Drug Administration approval for urological procedures in 2018. Here, we describe the first experience performing single-port robot-assisted donor nephrectomy (RADN) using the da Vinci SP® surgical system, present 90-day clinical outcomes, and discuss tips for operative success.</p><p><strong>Methods: </strong>Seven consecutive patients underwent single-port RADN at a single institution between September 1, 2020 and March 31, 2021. Surgery was performed through a single, 60 mm Pfannenstiel incision with a 12 mm periumbilical assistant port for suction and vascular stapling. Donor characteristics, operative details, 90-day donor clinical outcomes, and recipient renal function were retrospectively evaluated.</p><p><strong>Results: </strong>Four female and three male patients successfully underwent single-port RADN without conversion to standard multiport or open approach. Six cases were left-sided. Estimated blood loss for each procedure was ≤ 50 mL. Mean operative time, warm ischemia time, and extraction time were 218.3 minutes (standard deviation [SD]: 16.3 minutes), 5 minutes 4 seconds (SD: 56 seconds), and 3 minutes 37 seconds (SD: 38 seconds). Mean pre-operative creatinine and estimated glomerular filtration rate were 0.79 mg/dL and 107.3 mL/min/1.73m<sup>2</sup>, respectively. At six week's follow up, they were 1.22 mg/dL and 66.1 mL/min/1.73m<sup>2</sup>. Average pain score at 48 hours postoperatively was 1.7/10. There were no Clavien-Dindo grade ≥ III complications within 90 days. All recipients experienced immediate and sustained return of renal function post-transplant.</p><p><strong>Conclusion: </strong>Single-port RADN is a technically feasible and safe procedure with the da Vinci SP® system and can confer acceptable functional and cosmetic outcomes. Future studies are needed to define long-term outcomes and compare with previously established techniques for donor nephrectomy.</p>","PeriodicalId":17679,"journal":{"name":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","volume":"25 4","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/98/e2021.00062.PMC8692076.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4293/JSLS.2021.00062","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The da Vinci SP® Surgical System received U.S. Food and Drug Administration approval for urological procedures in 2018. Here, we describe the first experience performing single-port robot-assisted donor nephrectomy (RADN) using the da Vinci SP® surgical system, present 90-day clinical outcomes, and discuss tips for operative success.
Methods: Seven consecutive patients underwent single-port RADN at a single institution between September 1, 2020 and March 31, 2021. Surgery was performed through a single, 60 mm Pfannenstiel incision with a 12 mm periumbilical assistant port for suction and vascular stapling. Donor characteristics, operative details, 90-day donor clinical outcomes, and recipient renal function were retrospectively evaluated.
Results: Four female and three male patients successfully underwent single-port RADN without conversion to standard multiport or open approach. Six cases were left-sided. Estimated blood loss for each procedure was ≤ 50 mL. Mean operative time, warm ischemia time, and extraction time were 218.3 minutes (standard deviation [SD]: 16.3 minutes), 5 minutes 4 seconds (SD: 56 seconds), and 3 minutes 37 seconds (SD: 38 seconds). Mean pre-operative creatinine and estimated glomerular filtration rate were 0.79 mg/dL and 107.3 mL/min/1.73m2, respectively. At six week's follow up, they were 1.22 mg/dL and 66.1 mL/min/1.73m2. Average pain score at 48 hours postoperatively was 1.7/10. There were no Clavien-Dindo grade ≥ III complications within 90 days. All recipients experienced immediate and sustained return of renal function post-transplant.
Conclusion: Single-port RADN is a technically feasible and safe procedure with the da Vinci SP® system and can confer acceptable functional and cosmetic outcomes. Future studies are needed to define long-term outcomes and compare with previously established techniques for donor nephrectomy.
期刊介绍:
JSLS, Journal of the Society of Laparoscopic & Robotic Surgeons publishes original scientific articles on basic science and technical topics in all the fields involved with laparoscopic, robotic, and minimally invasive surgery. CRSLS, MIS Case Reports from SLS is dedicated to the publication of Case Reports in the field of minimally invasive surgery. The journals seek to advance our understandings and practice of minimally invasive, image-guided surgery by providing a forum for all relevant disciplines and by promoting the exchange of information and ideas across specialties.