Mechanical properties, in vitro and in vivo biocompatibility analysis of pure iron porous implant produced by metal injection molding: A new eco-friendly feedstock from natural rubber (Hevea brasiliensis)
Diego Pacheco Wermuth , Thaís Casagrande Paim , Isadora Bertaco , Carla Zanatelli , Liliana Ivet Sous Naasani , Mônica Slaviero , David Driemeier , André Carvalho Tavares , Vinicius Martins , Camila Ferreira Escobar , Luis Alberto Loureiro dos Santos , Lirio Schaeffer , Márcia Rosângela Wink
{"title":"Mechanical properties, in vitro and in vivo biocompatibility analysis of pure iron porous implant produced by metal injection molding: A new eco-friendly feedstock from natural rubber (Hevea brasiliensis)","authors":"Diego Pacheco Wermuth , Thaís Casagrande Paim , Isadora Bertaco , Carla Zanatelli , Liliana Ivet Sous Naasani , Mônica Slaviero , David Driemeier , André Carvalho Tavares , Vinicius Martins , Camila Ferreira Escobar , Luis Alberto Loureiro dos Santos , Lirio Schaeffer , Márcia Rosângela Wink","doi":"10.1016/j.msec.2021.112532","DOIUrl":null,"url":null,"abstract":"<div><p>Metal injection molding (MIM) has become an important manufacturing technology for biodegradable medical devices. As a biodegradable metal, pure iron is a promising biomaterial due to its mechanical properties and biocompatibility. In light of this, we performed the first study that manufactured and evaluated the <em>in vitro</em> and <em>in vivo</em> biocompatibility of samples of iron porous implants produced by MIM with a new eco-friendly feedstock from natural rubber (<em>Hevea brasiliensis</em>), a promisor binder that provides elastic property in the green parts. The iron samples were submitted to tests to determine density, microhardness, hardness, yield strength, and stretching. The biocompatibility of the samples was studied <em>in vitro</em> with adipose-derived mesenchymal stromal cells (ADSCs) and erythrocytes, and <em>in vivo</em> on a preclinical model with Wistar rats, testing the iron samples after subcutaneous implant. Results showed that the manufactured samples have adequate physical, and mechanical characteristics to biomedical devices and they are cytocompatible with ADSCs, hemocompatible and biocompatible with Wistars rats. Therefore, pure iron produced by MIM can be considered a promising material for biomedical applications.</p></div>","PeriodicalId":18212,"journal":{"name":"Materials science & engineering. C, Materials for biological applications","volume":"131 ","pages":"Article 112532"},"PeriodicalIF":8.1000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S092849312100672X/pdfft?md5=10dbb5eeff57c3eebfc27ae57978b715&pid=1-s2.0-S092849312100672X-main.pdf","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials science & engineering. C, Materials for biological applications","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S092849312100672X","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 9
Abstract
Metal injection molding (MIM) has become an important manufacturing technology for biodegradable medical devices. As a biodegradable metal, pure iron is a promising biomaterial due to its mechanical properties and biocompatibility. In light of this, we performed the first study that manufactured and evaluated the in vitro and in vivo biocompatibility of samples of iron porous implants produced by MIM with a new eco-friendly feedstock from natural rubber (Hevea brasiliensis), a promisor binder that provides elastic property in the green parts. The iron samples were submitted to tests to determine density, microhardness, hardness, yield strength, and stretching. The biocompatibility of the samples was studied in vitro with adipose-derived mesenchymal stromal cells (ADSCs) and erythrocytes, and in vivo on a preclinical model with Wistar rats, testing the iron samples after subcutaneous implant. Results showed that the manufactured samples have adequate physical, and mechanical characteristics to biomedical devices and they are cytocompatible with ADSCs, hemocompatible and biocompatible with Wistars rats. Therefore, pure iron produced by MIM can be considered a promising material for biomedical applications.
期刊介绍:
Materials Today is a community committed to fostering the creation and sharing of knowledge and experience in materials science. With the support of Elsevier, this community publishes high-impact peer-reviewed journals, organizes academic conferences, and conducts educational webinars, among other initiatives. It serves as a hub for advancing materials science and facilitating collaboration within the scientific community.