A Novel Subtraction Method to Reduce Metal Artifacts of Cerebral Aneurysm Embolism Coils.

IF 2.4 3区 医学 Q2 CLINICAL NEUROLOGY Clinical Neuroradiology Pub Date : 2022-09-01 Epub Date: 2022-01-22 DOI:10.1007/s00062-021-01125-y
Hanpei Zheng, Ming Yang, Yuxi Jia, Lan Zhang, Xiaojie Sun, Yangjing Zhang, Zhuang Nie, Hongying Wu, Xiaohui Zhang, Ziqiao Lei, Wang Jing
{"title":"A Novel Subtraction Method to Reduce Metal Artifacts of Cerebral Aneurysm Embolism Coils.","authors":"Hanpei Zheng,&nbsp;Ming Yang,&nbsp;Yuxi Jia,&nbsp;Lan Zhang,&nbsp;Xiaojie Sun,&nbsp;Yangjing Zhang,&nbsp;Zhuang Nie,&nbsp;Hongying Wu,&nbsp;Xiaohui Zhang,&nbsp;Ziqiao Lei,&nbsp;Wang Jing","doi":"10.1007/s00062-021-01125-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate a novel subtraction method (S-MAR), combing metal artifact reduction (MAR), virtual monochromatic imaging (VMI), and subtraction CT angiography (CTA) to remove the metal artifacts of coils after endovascular embolotherapy of intracranial aneurysms.</p><p><strong>Method: </strong>In this retrospective study, 29 patients with 38 coils after endovascular embolotherapy of intracranial aneurysms who underwent cerebral CTA using a dual-layer detector spectral CT were included. Conventional CT images (CI), virtual non-enhanced (VNC) images and VMI ranging from 40 to 120 KeV in steps of 10 were reconstructed. These images were then postprocessed to CI<sub>MAR</sub>, VMI<sub>MAR</sub> and VNC<sub>MAR</sub> with MAR software (O-MAR; Philips Healthcare, Cleveland, OH, USA). The novel subtraction method (S-MAR) was derived from subtraction imaging between VNC<sub>MAR</sub> and the optimal VMI<sub>MAR</sub>. Contrast-to-noise (CNR) and Noise<sub>(Background)</sub> of CI, CI<sub>MAR</sub>, VMI, and VMI<sub>MAR</sub> were calculated quantitatively. Two Independent radiologists qualitatively assessed artifacts in all images using coil artifact score (CA score), a 5-point Likert scale. Besides, all coils were divided into two groups (group 1: diameter < 5.0 mm, group 2: diameter ≥ 5.0 mm). Differences between two groups were statistically analyzed.</p><p><strong>Results: </strong>The optimal KeV was 40 KeV. Strong correlations between diameter of coils and the CA score of CI were found (r<sub>s</sub> = 0.652, P < 0.05). CNR, Noise and CA score were significantly improved by CI<sub>MAR</sub> and VMI<sub>MAR</sub> compared with CI (P < 0.05). The S‑MAR showed significantly better performance compared with CI, CI<sub>MAR</sub>, VMI, and VMI<sub>MAR</sub> in reducing metal coil artifacts according to the CA score (P < 0.05), especially in group 2.</p><p><strong>Conclusion: </strong>The novel S‑MAR proved to be a promising method to reduce coil metal artifacts and elevate the vessel visualization adjacent to coils. It could develop to be widely used in cerebral CTA after coiled aneurysms.</p>","PeriodicalId":49298,"journal":{"name":"Clinical Neuroradiology","volume":"32 3","pages":"687-694"},"PeriodicalIF":2.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00062-021-01125-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 13

Abstract

Objective: To investigate a novel subtraction method (S-MAR), combing metal artifact reduction (MAR), virtual monochromatic imaging (VMI), and subtraction CT angiography (CTA) to remove the metal artifacts of coils after endovascular embolotherapy of intracranial aneurysms.

Method: In this retrospective study, 29 patients with 38 coils after endovascular embolotherapy of intracranial aneurysms who underwent cerebral CTA using a dual-layer detector spectral CT were included. Conventional CT images (CI), virtual non-enhanced (VNC) images and VMI ranging from 40 to 120 KeV in steps of 10 were reconstructed. These images were then postprocessed to CIMAR, VMIMAR and VNCMAR with MAR software (O-MAR; Philips Healthcare, Cleveland, OH, USA). The novel subtraction method (S-MAR) was derived from subtraction imaging between VNCMAR and the optimal VMIMAR. Contrast-to-noise (CNR) and Noise(Background) of CI, CIMAR, VMI, and VMIMAR were calculated quantitatively. Two Independent radiologists qualitatively assessed artifacts in all images using coil artifact score (CA score), a 5-point Likert scale. Besides, all coils were divided into two groups (group 1: diameter < 5.0 mm, group 2: diameter ≥ 5.0 mm). Differences between two groups were statistically analyzed.

Results: The optimal KeV was 40 KeV. Strong correlations between diameter of coils and the CA score of CI were found (rs = 0.652, P < 0.05). CNR, Noise and CA score were significantly improved by CIMAR and VMIMAR compared with CI (P < 0.05). The S‑MAR showed significantly better performance compared with CI, CIMAR, VMI, and VMIMAR in reducing metal coil artifacts according to the CA score (P < 0.05), especially in group 2.

Conclusion: The novel S‑MAR proved to be a promising method to reduce coil metal artifacts and elevate the vessel visualization adjacent to coils. It could develop to be widely used in cerebral CTA after coiled aneurysms.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种减少脑动脉瘤栓塞线圈金属伪影的新减法。
目的:探讨一种新的减影方法(S-MAR),结合金属伪影还原(MAR)、虚拟单色成像(VMI)和减影CT血管造影(CTA)去除颅内动脉瘤血管内栓塞治疗后线圈的金属伪影。方法:回顾性分析29例38圈颅内动脉瘤血管内栓塞治疗后行双层探测光谱CT脑CTA的患者。重建常规CT图像(CI)、虚拟非增强图像(VNC)和40 ~ 120kev的VMI图像(每10步)。然后用MAR软件将这些图像后处理成CIMAR、VMIMAR和VNCMAR。Philips Healthcare, Cleveland, OH, USA)。基于VNCMAR与最优VMIMAR之间的相减成像,提出了一种新的减法(S-MAR)。定量计算CI、CIMAR、VMI和VMIMAR的噪声对比(CNR)和背景噪声(Noise(Background))。两名独立的放射科医生使用线圈伪影评分(CA评分),即5分李克特量表,对所有图像中的伪影进行定性评估。并将所有线圈分为两组(1组:直径)结果:最佳KeV为40 KeV。发现线圈直径与CI CA评分之间存在较强的相关性(rs = 0.652,P MAR和VMIMAR与CI (P MAR, VMI和VMIMAR)相比,根据CA评分减少金属线圈伪影(P )结论:新型S - MAR被证明是一种很有前途的方法,可以减少线圈金属伪影,提高线圈附近血管的可见性。它在颅内动脉瘤后的CTA中具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Neuroradiology
Clinical Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.00
自引率
3.60%
发文量
106
审稿时长
>12 weeks
期刊介绍: Clinical Neuroradiology provides current information, original contributions, and reviews in the field of neuroradiology. An interdisciplinary approach is accomplished by diagnostic and therapeutic contributions related to associated subjects. The international coverage and relevance of the journal is underlined by its being the official journal of the German, Swiss, and Austrian Societies of Neuroradiology.
期刊最新文献
Endovascular Treatment of Carotid Artery Dissection Caused by Eagle's Syndrome : Case Report. Pre-stroke Functional Status in Patients Undergoing Mechanical Thrombectomy: How Relevant Are False Estimations in the Emergency Setting? The DERIVO 2 Heal Embolization Device in the Treatment of Ruptured and Unruptured Intracranial Aneurysms: a Retrospective Multicenter Study. A New Fibrin-Heparine Coated Self-Expanding Stent for the Rescue Treatment of Intracranial Stenosis-a Multicentric Study. Trevo 3 Mm and/or AXS Catalyst 5 for the Treatment of Medium Distal Vessel Occlusion Stroke-results from the ASSIST Registry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1