Accuracy of indirect bonding trays - a measurement algorithm.

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Computerized Dentistry Pub Date : 2022-09-20 DOI:10.3290/j.ijcd.b2599775
Petra Julia Koch, Marco Albrecht, Wei-Cheng Lin, Paul-Georg Jost-Brinkmann
{"title":"Accuracy of indirect bonding trays - a measurement algorithm.","authors":"Petra Julia Koch,&nbsp;Marco Albrecht,&nbsp;Wei-Cheng Lin,&nbsp;Paul-Georg Jost-Brinkmann","doi":"10.3290/j.ijcd.b2599775","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To present an image-processing measurement algorithm to evaluate the transfer accuracy of indirect bonding (IDB) trays, exemplified by a CAD/CAM-based IDB tray integrated into a digital orthodontic workflow.</p><p><strong>Materials and methods: </strong>Plaster casts of 24 patients with full dentition and different malocclusions were scanned with an intraoral scanner (Trios; 3Shape, Copenhagen, Denmark) to obtain digital models, which served for the virtual placement of orthodontic brackets in simulation software (OnyxCeph; Image Instruments, Chemnitz, Germany). The resulting STL files were sent to a dental laboratory (CA Digital; Hilden, Germany) for the production of INDIVIDUA IDB trays. These trays were used to transfer the brackets to the respective plaster casts. Finally, a second scan was performed to record the actual bracket positions. The transfer accuracy was then analyzed by a measurement algorithm scripted to automation, which calculated the deviations of the planned and real bracket positions with a local best-fit alignment, resulting in three linear and three angular measurements for each bracket.</p><p><strong>Results: </strong>In total, 622 brackets and tubes were transferred successfully. The presented algorithm analyzed the transfer accuracy and demonstrated that the linear measurements were 98.3% within the range of the American Board of Orthodontics standard. The angular measurements were 86.7% within this range when the INDIVIDUA IDB tray was used.</p><p><strong>Conclusion: </strong>Scripted measurement algorithms facilitated the evaluation of present and future materials and designs for IDB trays to obtain an efficient solution for orthodontic practice. The INDIVIDUA IDB tray is a digital alternative to conventional IDB trays (Int J Comput Dent 2022;25(3):295-302; doi: 10.3290/j.ijcd.b2599775).</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"25 3","pages":"295-302"},"PeriodicalIF":1.8000,"publicationDate":"2022-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b2599775","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Aim: To present an image-processing measurement algorithm to evaluate the transfer accuracy of indirect bonding (IDB) trays, exemplified by a CAD/CAM-based IDB tray integrated into a digital orthodontic workflow.

Materials and methods: Plaster casts of 24 patients with full dentition and different malocclusions were scanned with an intraoral scanner (Trios; 3Shape, Copenhagen, Denmark) to obtain digital models, which served for the virtual placement of orthodontic brackets in simulation software (OnyxCeph; Image Instruments, Chemnitz, Germany). The resulting STL files were sent to a dental laboratory (CA Digital; Hilden, Germany) for the production of INDIVIDUA IDB trays. These trays were used to transfer the brackets to the respective plaster casts. Finally, a second scan was performed to record the actual bracket positions. The transfer accuracy was then analyzed by a measurement algorithm scripted to automation, which calculated the deviations of the planned and real bracket positions with a local best-fit alignment, resulting in three linear and three angular measurements for each bracket.

Results: In total, 622 brackets and tubes were transferred successfully. The presented algorithm analyzed the transfer accuracy and demonstrated that the linear measurements were 98.3% within the range of the American Board of Orthodontics standard. The angular measurements were 86.7% within this range when the INDIVIDUA IDB tray was used.

Conclusion: Scripted measurement algorithms facilitated the evaluation of present and future materials and designs for IDB trays to obtain an efficient solution for orthodontic practice. The INDIVIDUA IDB tray is a digital alternative to conventional IDB trays (Int J Comput Dent 2022;25(3):295-302; doi: 10.3290/j.ijcd.b2599775).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
间接键合托盘的精度-一种测量算法。
目的:提出一种图像处理测量算法来评估间接粘接(IDB)托盘的传递精度,以CAD/ cam为基础的IDB托盘集成到数字正畸工作流程中为例。材料与方法:对24例全牙列不同类型错牙合患者的石膏模型进行口腔内扫描(Trios;3Shape, Copenhagen, Denmark)获得数字模型,用于在仿真软件(OnyxCeph;Image Instruments,开姆尼茨,德国)。生成的STL文件被发送到牙科实验室(CA Digital;Hilden,德国)用于生产INDIVIDUA IDB托盘。这些托盘被用来将支架转移到各自的石膏模型上。最后,进行第二次扫描以记录实际的支架位置。然后通过编写到自动化的测量算法分析传递精度,该算法通过局部最适合对准计算计划和实际支架位置的偏差,从而对每个支架进行三次线性和三次角度测量。结果:共成功转移托槽管622例。该算法对传递精度进行了分析,结果表明线性测量值在美国正畸委员会标准范围内达到98.3%。当使用INDIVIDUA IDB托盘时,角度测量值在该范围内为86.7%。结论:脚本化测量算法有助于评估当前和未来IDB托盘的材料和设计,以获得正畸实践的有效解决方案。individual IDB托盘是传统IDB托盘的数字替代品(Int J computer Dent 2022;25(3):295-302;doi: 10.3290 / j.ijcd.b2599775)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
期刊最新文献
Impact of Digital Manufacturing Methods on the Accuracy of Ceramic Crowns. Accuracy of imaging software usable in clinical settings for 3D rendering of tooth structures. Digital workflow in oral splint manufacturing. Deep learning for diagnostic charting on pediatric panoramic radiographs. Preformed customized healing abutments in a biologically oriented preparation technique procedure: a 3-year retrospective case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1