{"title":"Real-time ultrasound-guided epidural catheter placement in infants: a case series","authors":"","doi":"10.1016/j.bjane.2022.03.004","DOIUrl":null,"url":null,"abstract":"<div><p>Although epidural catheter insertion under ultrasound (US) guidance in the pediatric age group has been reported in the literature, it is yet to be adopted widely in clinical practice. The incomplete fusion of bones in pediatric patients provides an acoustic window for the US. The epidural space in children is at shallow depth, hence a high-frequency probe, which provides better resolution can be used. We present a case series in which real-time US-guided epidural catheter placement was performed in 10 infants in lower thoracic and upper lumbar interspaces. We reiterate that the use of real-time US during epidural catheter placement in patients increases the success rate of epidural catheter placement while decreasing procedural complications.</p></div>","PeriodicalId":32356,"journal":{"name":"Brazilian Journal of Anesthesiology","volume":"74 5","pages":"Article 744368"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0104001422000343/pdfft?md5=091fc89b8e101618c2266c199c97219a&pid=1-s2.0-S0104001422000343-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0104001422000343","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Although epidural catheter insertion under ultrasound (US) guidance in the pediatric age group has been reported in the literature, it is yet to be adopted widely in clinical practice. The incomplete fusion of bones in pediatric patients provides an acoustic window for the US. The epidural space in children is at shallow depth, hence a high-frequency probe, which provides better resolution can be used. We present a case series in which real-time US-guided epidural catheter placement was performed in 10 infants in lower thoracic and upper lumbar interspaces. We reiterate that the use of real-time US during epidural catheter placement in patients increases the success rate of epidural catheter placement while decreasing procedural complications.
尽管已有文献报道在超声(US)引导下为儿科患者插入硬膜外导管,但这种方法尚未在临床实践中广泛采用。小儿患者的骨骼尚未完全融合,这为 US 提供了一个声窗。儿童硬膜外腔深度较浅,因此可以使用分辨率更高的高频探头。我们介绍了一个病例系列,其中有 10 名婴儿在下胸椎和上腰椎间隙进行了实时 US 引导硬膜外导管置入术。我们重申,在硬膜外导管置入过程中使用实时 US 可以提高硬膜外导管置入的成功率,同时减少手术并发症。