{"title":"Comparing the color match of monolithic CAD-CAM dental ceramics with the VITA Classical shade guide","authors":"","doi":"10.1016/j.prosdent.2022.06.024","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><p>Matching the shade selected and the final color of a ceramic restoration is challenging, and studies on matching monolithic ceramics to the shade selected are lacking.</p></div><div><h3>Purpose</h3><p>The purpose of this in vitro study was to compare the color match of monolithic lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), presintered zirconia-reinforced lithium silicate (PS-ZLS), polymer-infiltrated ceramic network (PICN), and multilayer zirconia with the 3 modes of the VITA Classical shade guide.</p></div><div><h3>Material and methods</h3><p>This study was performed on 50 rectangular plates (14×12×1 mm) of 5 types of ceramics with A2 shade (n=10). Zirconia specimens were evaluated in 3 locations: incisal, medial, and cervical thirds. The color coordinates of the specimens of all 7 groups were measured on #3 and #8 Ivoclar Natural Die Color material by using a reflective spectrophotometer. The color coordinates of A2 VITA shade were measured in 5 modes: without backing placed in specimen holder, shade tab on the backgrounds #3 and #8, and 1-mm-thick shade tab on the backgrounds #3 and #8. The color difference of each specimen with 3 modes of A2 shade (without backing and on similar backgrounds) was calculated by using the ΔE<sub>00</sub><span> formula, and comparison among groups was performed by using 2-way ANOVA and Tamhane post hoc tests. The comparison of ΔE</span><sub>00</sub> between the values obtained from backgrounds #3 and #8 was performed by using the independent <em>t</em> test (α=.05).</p></div><div><h3>Results</h3><p>In both backgrounds, statistically significant differences were found between the studied groups and VITA shade (<em>P</em>&lt;.001). In most situations, the amount of color difference was lowest for the “shade tab on the backgrounds” mode. On background #3, the highest color difference was related to ZLS (6.48 ±0.23), and the lowest values were observed in the PICN group (1.02 ±0.31). On background #8, the highest color difference was related to ZLS compared with the “without backing” mode (8.62 ±0.27), and the lowest values were reported for ZLS compared with the “shade tab on the backgrounds” mode (1.27 ±0.44). The independent <em>t</em> test showed a statistically significant color difference on the 2 different backgrounds for all situations (<em>P</em>&lt;.001).</p></div><div><h3>Conclusions</h3><p>Color selection of monolithic ceramics with the VITA Classical shade guide is improved by placing the VITA tabs on a similar background. Background color has a significant effect on the final shade of the monolithic ceramics. Choosing the correct color for LDS, ZLS, and PS-ZLS requires more care than for PICN and zirconia.</p></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391322004632","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Matching the shade selected and the final color of a ceramic restoration is challenging, and studies on matching monolithic ceramics to the shade selected are lacking.

Purpose

The purpose of this in vitro study was to compare the color match of monolithic lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), presintered zirconia-reinforced lithium silicate (PS-ZLS), polymer-infiltrated ceramic network (PICN), and multilayer zirconia with the 3 modes of the VITA Classical shade guide.

Material and methods

This study was performed on 50 rectangular plates (14×12×1 mm) of 5 types of ceramics with A2 shade (n=10). Zirconia specimens were evaluated in 3 locations: incisal, medial, and cervical thirds. The color coordinates of the specimens of all 7 groups were measured on #3 and #8 Ivoclar Natural Die Color material by using a reflective spectrophotometer. The color coordinates of A2 VITA shade were measured in 5 modes: without backing placed in specimen holder, shade tab on the backgrounds #3 and #8, and 1-mm-thick shade tab on the backgrounds #3 and #8. The color difference of each specimen with 3 modes of A2 shade (without backing and on similar backgrounds) was calculated by using the ΔE00 formula, and comparison among groups was performed by using 2-way ANOVA and Tamhane post hoc tests. The comparison of ΔE00 between the values obtained from backgrounds #3 and #8 was performed by using the independent t test (α=.05).

Results

In both backgrounds, statistically significant differences were found between the studied groups and VITA shade (P<.001). In most situations, the amount of color difference was lowest for the “shade tab on the backgrounds” mode. On background #3, the highest color difference was related to ZLS (6.48 ±0.23), and the lowest values were observed in the PICN group (1.02 ±0.31). On background #8, the highest color difference was related to ZLS compared with the “without backing” mode (8.62 ±0.27), and the lowest values were reported for ZLS compared with the “shade tab on the backgrounds” mode (1.27 ±0.44). The independent t test showed a statistically significant color difference on the 2 different backgrounds for all situations (P<.001).

Conclusions

Color selection of monolithic ceramics with the VITA Classical shade guide is improved by placing the VITA tabs on a similar background. Background color has a significant effect on the final shade of the monolithic ceramics. Choosing the correct color for LDS, ZLS, and PS-ZLS requires more care than for PICN and zirconia.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较整体式 CAD-CAM 牙科陶瓷与 VITA 经典色调指南的颜色匹配。
问题陈述:陶瓷修复体所选色调与最终颜色的匹配具有挑战性,目前还缺乏关于单片陶瓷与所选色调匹配的研究。目的:这项体外研究的目的是比较整体二硅酸锂(LDS)、氧化锆增强硅酸锂(ZLS)、预烧结氧化锆增强硅酸锂(PS-ZLS)、聚合物浸润陶瓷网络(PICN)和多层氧化锆与 VITA 经典色调指南的 3 种模式的颜色匹配情况:研究对象是 50 块矩形板(14×12×1 毫米),5 种陶瓷,A2 色调(n=10)。氧化锆试样在 3 个位置进行评估:切缘、内侧和颈三分之二。使用反射分光光度计测量了所有 7 组试样在 3 号和 8 号 Ivoclar Natural Die Color 材料上的色坐标。在 5 种模式下测量了 A2 VITA 树荫的色坐标:在标本架上不放置衬垫、在 3 号和 8 号背景上放置树荫标签、在 3 号和 8 号背景上放置 1 毫米厚的树荫标签。使用 ΔE00 公式计算了每个试样在 3 种 A2 遮光模式(无衬底和在相似背景上)下的色差,并使用 2 向方差分析和 Tamhane 后检验进行了组间比较。3 号和 8 号背景的 ΔE00 值比较采用独立 t 检验(α=.05):结果:在两个背景中,研究组与 VITA 色调之间存在显著的统计学差异(PConclusions.P.):使用 VITA 经典色调指南对整体陶瓷进行颜色选择时,将 VITA 标签放在相似的背景上会有所改善。背景颜色对整体陶瓷的最终色调有很大影响。与 PICN 和氧化锆相比,为 LDS、ZLS 和 PS-ZLS 选择正确的颜色需要更加谨慎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Accuracy of a calibration method based on cone beam computed tomography and intraoral scanner data registration for robot-assisted implant placement: An in vitro study. Can nonhazardous postprocessing cleaning solutions enable adequate surface properties for printed dental casts in different resins? Evaluation of adherence of Candida albicans to differently manufactured acrylic resin denture base materials. Relationship between anterior occlusion, arch dimension, and mandibular movement during speech articulation: A three-dimensional analysis. Response to Letter to the Editor regarding, "The application of 3D printing in dentistry: A bibliometric analysis from 2012 to 2023 (J Prosthet Dent. 2024 Jul 1)".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1