Q-value customized versus wavefront-optimized ablation in femtosecond laser-assisted LASIK for myopia and myopic astigmatism: a prospective contralateral comparative study.
Magdi Mohammad Mostafa, Hazem Abdelmotaal, Khaled Abdelazeem, Islam Goda, Mahmoud Abdel-Radi
{"title":"Q-value customized versus wavefront-optimized ablation in femtosecond laser-assisted LASIK for myopia and myopic astigmatism: a prospective contralateral comparative study.","authors":"Magdi Mohammad Mostafa, Hazem Abdelmotaal, Khaled Abdelazeem, Islam Goda, Mahmoud Abdel-Radi","doi":"10.1186/s40662-022-00312-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Corneal refractive surgery for myopia results in an oblate shift with increased postoperative aberrations inversely affecting the quality of vision. Aspheric ablation profiles have been introduced to minimize such a problem. The aim of this study was to compare changes in corneal asphericity, central and mid-peripheral pachymetry between the Q-value customized and the wavefront-optimized (WFO) ablation profiles.</p><p><strong>Methods: </strong>A prospective, comparative non-randomized fellow eye study was conducted. Eighty eyes of 40 eligible patients underwent femtosecond laser-assisted laser in situ keratomileusis for myopia and myopic astigmatism. In each patient, the more myopic eye was included in the custom-Q ablation experimental group and the other less myopic eye was included in the WFO control group. For the custom-Q group, the target asphericity was set to the preoperative Q-value. Corneal asphericity, central and mid-peripheral pachymetric changes and the root mean square of corneal higher-order aberrations (RMSh) were assessed 6 months following surgery. Visual and refractive outcomes were also evaluated in both platforms 6 months postoperatively.</p><p><strong>Results: </strong>The mean preoperative refractive spherical equivalent was significantly more myopic in the custom-Q group than in the WFO group (P = 0.001). The mean Q-value changed from - 0.2 ± 0.1 to 0.6 ± 0.7 and from - 0.2 ± 0.1 to 0.4 ± 0.5 in the custom-Q and WFO groups, respectively. The oblate shift in corneal asphericity was not significantly different between both treatment groups (P = 0.094). The mean ablation depth at the pupillary center was significantly greater in the custom-Q group (P = 0.011), while there was no significant difference at the mid-peripheral pachymetry (P = 0.256). The RMSh significantly increased in both treatment profiles (P < 0.001) with no significant difference between the two groups (P = 0.06). The uncorrected distance visual acuity (UDVA) and the manifest refraction spherical equivalents (MRSE) significantly improved in both treatment groups (P < 0.001).</p><p><strong>Conclusions: </strong>The custom-Q treatment profile with target asphericity set at the preoperative Q-value achieved comparable outcomes vs. the WFO profile in terms of postoperative corneal asphericity and mid-peripheral pachymetry despite the greater amount of ablation, the smaller optical zone, and the resulting increase in postoperative corneal flattening in the custom-Q group. Trial registration (Clinicaltrials.gov): NCT04738903, 4 February 2021- Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04738903.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2022-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9628024/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00312-3","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 1
Abstract
Background: Corneal refractive surgery for myopia results in an oblate shift with increased postoperative aberrations inversely affecting the quality of vision. Aspheric ablation profiles have been introduced to minimize such a problem. The aim of this study was to compare changes in corneal asphericity, central and mid-peripheral pachymetry between the Q-value customized and the wavefront-optimized (WFO) ablation profiles.
Methods: A prospective, comparative non-randomized fellow eye study was conducted. Eighty eyes of 40 eligible patients underwent femtosecond laser-assisted laser in situ keratomileusis for myopia and myopic astigmatism. In each patient, the more myopic eye was included in the custom-Q ablation experimental group and the other less myopic eye was included in the WFO control group. For the custom-Q group, the target asphericity was set to the preoperative Q-value. Corneal asphericity, central and mid-peripheral pachymetric changes and the root mean square of corneal higher-order aberrations (RMSh) were assessed 6 months following surgery. Visual and refractive outcomes were also evaluated in both platforms 6 months postoperatively.
Results: The mean preoperative refractive spherical equivalent was significantly more myopic in the custom-Q group than in the WFO group (P = 0.001). The mean Q-value changed from - 0.2 ± 0.1 to 0.6 ± 0.7 and from - 0.2 ± 0.1 to 0.4 ± 0.5 in the custom-Q and WFO groups, respectively. The oblate shift in corneal asphericity was not significantly different between both treatment groups (P = 0.094). The mean ablation depth at the pupillary center was significantly greater in the custom-Q group (P = 0.011), while there was no significant difference at the mid-peripheral pachymetry (P = 0.256). The RMSh significantly increased in both treatment profiles (P < 0.001) with no significant difference between the two groups (P = 0.06). The uncorrected distance visual acuity (UDVA) and the manifest refraction spherical equivalents (MRSE) significantly improved in both treatment groups (P < 0.001).
Conclusions: The custom-Q treatment profile with target asphericity set at the preoperative Q-value achieved comparable outcomes vs. the WFO profile in terms of postoperative corneal asphericity and mid-peripheral pachymetry despite the greater amount of ablation, the smaller optical zone, and the resulting increase in postoperative corneal flattening in the custom-Q group. Trial registration (Clinicaltrials.gov): NCT04738903, 4 February 2021- Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04738903.
期刊介绍:
Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.