Comparison of postoperative pain after the use of different nickel titanium instrumentation systems: a randomized clinical trial.

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE European Oral Research Pub Date : 2022-05-05 DOI:10.26650/eor.2022873271
Ozlem Sivas Yilmaz, Cangül Keskin, Duygu Hazal Acar, Hikmet Aydemir
{"title":"Comparison of postoperative pain after the use of different nickel titanium instrumentation systems: a randomized clinical trial.","authors":"Ozlem Sivas Yilmaz,&nbsp;Cangül Keskin,&nbsp;Duygu Hazal Acar,&nbsp;Hikmet Aydemir","doi":"10.26650/eor.2022873271","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Postoperative pain is a common complication in endodontics contributed by multiple etiological factors, which consist canal preparation instruments and kinematics. The aim of this randomized clinical trial compare the postoperative pain in terms of intensity and incidence after the use of different nickel titanium (NiTi) file systems.</p><p><strong>Patients and methods: </strong>In this randomized clinical trial (NCT03791762), a total of 150 patients were root canal treated by 2 experienced endodontists according to a standardised protocol. The subjects were randomly assigned to 1 of the 3 groups according to preparation instrument used: ProTaper Next (Dentsply Sirona, Ballaigues, Switzerland), Reciproc Blue (VDW, Munich, Germany) and WaveOne Gold (Dentsply Sirona). Following preparation the teeth underwent standardized root canal treatment procedures in a single visit. The patients were contacted to gather information about the incidence of pain and intensity at 6th, 12th, 18th, 24th, 48th, and 72nd hours postoperatively. The data were analysed using chi-square, one-way analysis of variance and post hoc Tukey tests and logistic regression analysis with 5% significance threshold.</p><p><strong>Results: </strong>No significant difference was found among preparation groups in relation to the intensity of postoperative pain. The incidence of postoperative pain was significantly linked with the preoperative pain presence with odds ratio values ranging between 2.06 and 4.08 irrespective of the preparation technique (P<0.05).</p><p><strong>Conclusion: </strong>The effects of reciprocating and the continuous rotary systems on the intensity and incidence of postoperative pain were found to be similar.</p>","PeriodicalId":41993,"journal":{"name":"European Oral Research","volume":"56 2","pages":"102-109"},"PeriodicalIF":0.9000,"publicationDate":"2022-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/d8/eor-056-102.PMC9377776.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26650/eor.2022873271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: Postoperative pain is a common complication in endodontics contributed by multiple etiological factors, which consist canal preparation instruments and kinematics. The aim of this randomized clinical trial compare the postoperative pain in terms of intensity and incidence after the use of different nickel titanium (NiTi) file systems.

Patients and methods: In this randomized clinical trial (NCT03791762), a total of 150 patients were root canal treated by 2 experienced endodontists according to a standardised protocol. The subjects were randomly assigned to 1 of the 3 groups according to preparation instrument used: ProTaper Next (Dentsply Sirona, Ballaigues, Switzerland), Reciproc Blue (VDW, Munich, Germany) and WaveOne Gold (Dentsply Sirona). Following preparation the teeth underwent standardized root canal treatment procedures in a single visit. The patients were contacted to gather information about the incidence of pain and intensity at 6th, 12th, 18th, 24th, 48th, and 72nd hours postoperatively. The data were analysed using chi-square, one-way analysis of variance and post hoc Tukey tests and logistic regression analysis with 5% significance threshold.

Results: No significant difference was found among preparation groups in relation to the intensity of postoperative pain. The incidence of postoperative pain was significantly linked with the preoperative pain presence with odds ratio values ranging between 2.06 and 4.08 irrespective of the preparation technique (P<0.05).

Conclusion: The effects of reciprocating and the continuous rotary systems on the intensity and incidence of postoperative pain were found to be similar.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同镍钛器械系统使用后术后疼痛的比较:一项随机临床试验。
目的:术后疼痛是牙髓学中常见的并发症,由多种病因引起,包括根管预备器械和运动学因素。本随机临床试验的目的是比较使用不同镍钛(NiTi)文件系统后术后疼痛的强度和发生率。患者和方法:在这项随机临床试验(NCT03791762)中,共有150名患者由2名经验丰富的牙髓医生根据标准化方案进行根管治疗。根据使用的制备工具,将受试者随机分为3组:ProTaper Next (Dentsply Sirona, Ballaigues, Switzerland)、Reciproc Blue (VDW, Munich, Germany)和WaveOne Gold (Dentsply Sirona)。预备后的牙齿在一次访问中进行标准化的根管治疗程序。分别于术后第6、12、18、24、48、72小时联系患者,了解疼痛发生率和强度。数据分析采用卡方、单因素方差分析、事后Tukey检验和5%显著性阈值的logistic回归分析。结果:各制剂组术后疼痛程度无明显差异。术后疼痛发生率与术前疼痛存在显著相关,且不论采用何种准备技术,比值比均在2.06 ~ 4.08之间(结论:往复和连续旋转系统对术后疼痛强度和发生率的影响相似)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Oral Research
European Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
23
审稿时长
12 weeks
期刊最新文献
Biocompatibility of different resin composites after polymerization with two light curing units: an immunohistochemical study. Prophylactic and therapeutic effects of (6)-shogaol on alveolar bone loss in experimental periodontitis. Comparative evaluation of digital radiography, electronic apex locator and simultaneous working length determination on postoperative pain after root canal treatment: a randomized clinical trial Cone beam computed tomography evaluation of c-shaped canal morphology in mandibular premolar teeth The effect of three different primary teeth rotary instrument systems on the amount of apically extruded debris in pulpectomy of primary teeth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1