Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest.
Garrhett G Via, David A Brueggeman, Joseph G Lyons, Isabelle C Ely, Andrew W Froehle, Anil B Krishnamurthy
{"title":"Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest.","authors":"Garrhett G Via, David A Brueggeman, Joseph G Lyons, Isabelle C Ely, Andrew W Froehle, Anil B Krishnamurthy","doi":"10.1186/s42836-022-00146-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of new total joint arthroplasty technologies, including patient-specific implants/instrumentation (PSI), computer-assisted (CA), and robotic-assisted (RA) techniques, is increasing. There is an ongoing debate regarding the value provided and potential concerns about conflicts of interest (COI).</p><p><strong>Methods: </strong>PRISMA guidelines were followed. PubMed, MEDLINE, and Web of Science databases were searched for total hip and knee arthroplasties, unicompartmental knee arthroplasties (UKA), PSI, CA, and RA. Bibliometric data, financial COI, clinical/functional scores, and patient-reported outcomes were assessed.</p><p><strong>Results: </strong>Eighty-seven studies were evaluated, with 35 (40.2%) including at least one author reporting COI, and 13 (14.9%) disclosing industry funding. COI and industry funding had no significant effects on outcomes (P = 0.682, P = 0.447), and there were no significant effects of conflicts or funding on level of evidence (P = 0.508, P = 0.826). Studies in which author(s) disclosed COI had significantly higher relative citation ratio (RCR) and impact factor (IF) than those without (P < 0.001, P = 0.032). Subanalysis demonstrated RA and PSI studies were more likely to report COI or industry funding (P = 0.045). RA (OR = 6.31, 95% CI: 1.61-24.68) and UKA (OR = 9.14, 95% CI: 1.43-58.53) had higher odds of reporting favorable outcomes than PSI.</p><p><strong>Conclusions: </strong>Author COIs (about 40%) may be lower than previously reported in orthopedic technologies/techniques reviews. Studies utilizing RA and PSI were more likely to report COI, while RA and UKA studies were more likely to report favorable outcomes than PSI. No statistically significant association between the presence of COIs and/or industry funding and the frequency of favorable outcomes or study level of evidence was found.</p><p><strong>Level of evidence: </strong>Level V Systematic Review.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623935/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-022-00146-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 1
Abstract
Background: The use of new total joint arthroplasty technologies, including patient-specific implants/instrumentation (PSI), computer-assisted (CA), and robotic-assisted (RA) techniques, is increasing. There is an ongoing debate regarding the value provided and potential concerns about conflicts of interest (COI).
Methods: PRISMA guidelines were followed. PubMed, MEDLINE, and Web of Science databases were searched for total hip and knee arthroplasties, unicompartmental knee arthroplasties (UKA), PSI, CA, and RA. Bibliometric data, financial COI, clinical/functional scores, and patient-reported outcomes were assessed.
Results: Eighty-seven studies were evaluated, with 35 (40.2%) including at least one author reporting COI, and 13 (14.9%) disclosing industry funding. COI and industry funding had no significant effects on outcomes (P = 0.682, P = 0.447), and there were no significant effects of conflicts or funding on level of evidence (P = 0.508, P = 0.826). Studies in which author(s) disclosed COI had significantly higher relative citation ratio (RCR) and impact factor (IF) than those without (P < 0.001, P = 0.032). Subanalysis demonstrated RA and PSI studies were more likely to report COI or industry funding (P = 0.045). RA (OR = 6.31, 95% CI: 1.61-24.68) and UKA (OR = 9.14, 95% CI: 1.43-58.53) had higher odds of reporting favorable outcomes than PSI.
Conclusions: Author COIs (about 40%) may be lower than previously reported in orthopedic technologies/techniques reviews. Studies utilizing RA and PSI were more likely to report COI, while RA and UKA studies were more likely to report favorable outcomes than PSI. No statistically significant association between the presence of COIs and/or industry funding and the frequency of favorable outcomes or study level of evidence was found.
背景:新的全关节置换术技术的使用越来越多,包括患者特异性植入物/器械(PSI)、计算机辅助(CA)和机器人辅助(RA)技术。关于提供的价值和对利益冲突(COI)的潜在担忧,存在持续的争论。方法:遵循PRISMA指南。检索PubMed、MEDLINE和Web of Science数据库,检索全髋关节和膝关节置换术、单室膝关节置换术(UKA)、PSI、CA和RA。评估文献计量学数据、财务COI、临床/功能评分和患者报告的结果。结果:87项研究被评估,其中35项(40.2%)包括至少一名作者报告COI, 13项(14.9%)披露了行业资助。COI和行业资助对结果无显著影响(P = 0.682, P = 0.447),冲突和资助对证据水平无显著影响(P = 0.508, P = 0.826)。作者披露COI的研究的相对引用率(RCR)和影响因子(IF)明显高于未披露的研究(P)。结论:作者COI(约40%)可能低于先前在骨科技术/技术综述中报道的水平。使用RA和PSI的研究更有可能报告COI,而RA和UKA研究比PSI更有可能报告有利的结果。coi的存在和/或行业资助与有利结果的频率或研究证据水平之间没有统计学上显著的关联。证据等级:V级系统评价。