A Novel Wire-Type Lead-Selective Electrode Based on Bis (1'-Hydroxy-2'-Acetonaphthone)-2,2'-Diiminodiethylamine

Zahra Pilehvari, Mohammad Reza Yaftian, Saeed Rayati, Massoumeh Parinejad
{"title":"A Novel Wire-Type Lead-Selective Electrode Based on Bis (1'-Hydroxy-2'-Acetonaphthone)-2,2'-Diiminodiethylamine","authors":"Zahra Pilehvari,&nbsp;Mohammad Reza Yaftian,&nbsp;Saeed Rayati,&nbsp;Massoumeh Parinejad","doi":"10.1002/adic.200790058","DOIUrl":null,"url":null,"abstract":"<p>The preparation of a lead-selective electrode based on bis(1'-hydroxy-2'-acetonaphthone)-2,2'-diiminodiethylamine (<b>L</b>) as sensing material is reported. The plasticized PVC membrane containing 30% PVC, 67% <i>ortho</i>-nitrophenyloctylether (NPOE) and 3% ionophore <b>L</b> was directly coated on a graphite rod. This electrode exhibits a nearly Nernstian slope of 27.8±0.2 mV decade<sup>-1</sup> over a concentration range 10<sup>-6</sup>−10<sup>-2</sup> M with a detection limit of 4.0×10<sup>-7</sup> M. The response time of the electrode was found to be &lt;20 s. The potential of the sensor was independent on pH variations in the range 5-7. The selectivity of the electrode towards lead ions over Na<sup>+</sup>, K<sup>+</sup>, Ag<sup>+</sup>, Ca<sup>2+</sup>, Sr<sup>2+</sup>, Fe<sup>2+</sup>, Co<sup>2+</sup>, Ni<sup>2+</sup>, Cu<sup>2+</sup>, Zn<sup>2+</sup>, Cd<sup>2+</sup>, La<sup>3+</sup>, Sm<sup>3+</sup> and Er<sup>3+</sup> ions was investigated. The prepared electrode was successfully used as an indicator for titration of a lead solution with a standard solution of EDTA. The applicability of the sensor for Pb<sup>2+</sup> measurement in various synthetic and real samples has been also demonstrated.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 8","pages":"747-757"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790058","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

The preparation of a lead-selective electrode based on bis(1'-hydroxy-2'-acetonaphthone)-2,2'-diiminodiethylamine (L) as sensing material is reported. The plasticized PVC membrane containing 30% PVC, 67% ortho-nitrophenyloctylether (NPOE) and 3% ionophore L was directly coated on a graphite rod. This electrode exhibits a nearly Nernstian slope of 27.8±0.2 mV decade-1 over a concentration range 10-6−10-2 M with a detection limit of 4.0×10-7 M. The response time of the electrode was found to be <20 s. The potential of the sensor was independent on pH variations in the range 5-7. The selectivity of the electrode towards lead ions over Na+, K+, Ag+, Ca2+, Sr2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, La3+, Sm3+ and Er3+ ions was investigated. The prepared electrode was successfully used as an indicator for titration of a lead solution with a standard solution of EDTA. The applicability of the sensor for Pb2+ measurement in various synthetic and real samples has been also demonstrated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于双(1′-羟基-2′-乙萘酮)-2,2′-二亚氨基二乙胺的新型导线型铅选择电极
报道了以双(1′-羟基-2′-乙萘酮)-2,2′-二亚氨基二乙胺(L)为传感材料制备的铅选择性电极。将含有30% PVC、67%邻硝基苯乙醚(NPOE)和3%离子载体L的增塑型PVC膜直接涂覆在石墨棒上。该电极在浓度范围为10-6−10-2 M时具有27.8±0.2 mV decade-1的近似纳恩斯蒂斜率,检测限为4.0×10-7 M。电极的响应时间为20 s。传感器的电位与pH值在5-7范围内的变化无关。研究了该电极对铅离子的选择性优于Na+、K+、Ag+、Ca2+、Sr2+、Fe2+、Co2+、Ni2+、Cu2+、Zn2+、Cd2+、La3+、Sm3+和Er3+离子。所制备的电极成功地用作铅溶液与EDTA标准溶液滴定的指示剂。该传感器在各种合成样品和实际样品中测量Pb2+的适用性也得到了证明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate Flotation Separation and Flame Atomic Absorption Spectrometric Determination of Trace Amount of Lead in Some Environmental Samples Investigation of Distribution of Heavy Metals between Blood Plasma and Blood Cells Kinetic-Catalytic and Spectrophotometric Determination of Hg(II) Using its Catalytic Effect on Ligand Substitution Reaction between Hexacyanoferrate(II) and Pyrazine PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1