{"title":"A Simple and Rapid Flow-Injection Chemiluminescence Method for the Determination of Noscapine with Ru(phen)32+-Ce(IV) System","authors":"Behzad Rezaei, Ali Mokhtari, Taghi Khayamian","doi":"10.1002/adic.200790046","DOIUrl":null,"url":null,"abstract":"<p>A new flow injection chemiluminescence (CL) system was used for the determination of noscapine. This technique is based on the reduction effect of noscapine on the Ru(phen)<sub>3</sub><sup>3+</sup>, which is produced by reaction between Ru(phen)<sub>3</sub><sup>2+</sup> and acidic Ce(IV) solutions, and this rapid reduction produces strong CL. Calibration plots were linear over the range of 3.0×10<sup>-7</sup>-2.0×10<sup>-6</sup> mol L<sup>-1</sup> and 2.0×10<sup>-6</sup>-2.0×10<sup>-4</sup> mol L<sup>-1</sup>. The CL intensity was so high, that it is able to produce a detection limit of 6.6×10<sup>-8</sup> M noscapine (3σ). The relative standard deviation of 2.0×10<sup>-6</sup> M noscapine was 1.0% (n=10). The proposed method was successfully applied for the flow injection determination of noscapine in cough and Tonin syrup samples. The results of real sample analyses show good recovery percentages (97.3-102.4%). The minimum sampling rate was 100 samples per hour.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 8","pages":"605-614"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790046","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
A new flow injection chemiluminescence (CL) system was used for the determination of noscapine. This technique is based on the reduction effect of noscapine on the Ru(phen)33+, which is produced by reaction between Ru(phen)32+ and acidic Ce(IV) solutions, and this rapid reduction produces strong CL. Calibration plots were linear over the range of 3.0×10-7-2.0×10-6 mol L-1 and 2.0×10-6-2.0×10-4 mol L-1. The CL intensity was so high, that it is able to produce a detection limit of 6.6×10-8 M noscapine (3σ). The relative standard deviation of 2.0×10-6 M noscapine was 1.0% (n=10). The proposed method was successfully applied for the flow injection determination of noscapine in cough and Tonin syrup samples. The results of real sample analyses show good recovery percentages (97.3-102.4%). The minimum sampling rate was 100 samples per hour.