Pekka Ahlholm, Frode Staxrud, Kirsi Sipilä, Pekka Vallittu
{"title":"Repair bond strength of bulk-fill composites: influence of different primers and direction of debonding stress.","authors":"Pekka Ahlholm, Frode Staxrud, Kirsi Sipilä, Pekka Vallittu","doi":"10.1080/26415275.2023.2258924","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this <i>in vitro</i> study was to evaluate the effect of different adhesion primers on the repair bond strength of bulk-fill resin composite and short-term hydrolytic stability of the repair interface before and after accelerated aging. In addition, direction of debonding stress was examined.</p><p><strong>Materials and methods: </strong>Bulk-fill substrates were aged in water for 14 days at 37 °C. Smooth resin composite surfaces were prepared for the substrates with a superfine grinding paper (FEPA #500, #1200, #2000). Test specimens were produced by attaching bulk-fill composite to the substrate surfaces, using three different primer/bonding systems. Specimens were aged 24 h at 37 °C in water, or thermal cycled (5-55 °C/5,000 cycles). Subsequently, shear bond strength and micro-tensile bond strength were evaluated. In total there were 60 specimens for the shear bond strength and 60 specimens for the micro-tensile bond strength measurements (30 stored in water 24 h, 30 thermal cycled, <i>n</i> = 10 in each primer/bonding mode).</p><p><strong>Results: </strong>The mean shear bond strength was 9.1-13.1 MPa after 24 h water storage and 6.9-10.7 MPa after thermal cycling. The mean micro-tensile bond strength was 28.7-45.8 MPa after 24 h water storage and 22.7-37.9 MPa after thermal cycling.</p><p><strong>Conclusion: </strong>The Ceramic primer (silane containing) seems to perform better than the three-step etch and rinse adhesive or the Composite primer. Shear-type stress had an adverse effect on the repair bond strength of bulk-fill resin composites.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":"10 1","pages":"2258924"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2f/63/IABO_10_2258924.PMC10519262.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/26415275.2023.2258924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The purpose of this in vitro study was to evaluate the effect of different adhesion primers on the repair bond strength of bulk-fill resin composite and short-term hydrolytic stability of the repair interface before and after accelerated aging. In addition, direction of debonding stress was examined.
Materials and methods: Bulk-fill substrates were aged in water for 14 days at 37 °C. Smooth resin composite surfaces were prepared for the substrates with a superfine grinding paper (FEPA #500, #1200, #2000). Test specimens were produced by attaching bulk-fill composite to the substrate surfaces, using three different primer/bonding systems. Specimens were aged 24 h at 37 °C in water, or thermal cycled (5-55 °C/5,000 cycles). Subsequently, shear bond strength and micro-tensile bond strength were evaluated. In total there were 60 specimens for the shear bond strength and 60 specimens for the micro-tensile bond strength measurements (30 stored in water 24 h, 30 thermal cycled, n = 10 in each primer/bonding mode).
Results: The mean shear bond strength was 9.1-13.1 MPa after 24 h water storage and 6.9-10.7 MPa after thermal cycling. The mean micro-tensile bond strength was 28.7-45.8 MPa after 24 h water storage and 22.7-37.9 MPa after thermal cycling.
Conclusion: The Ceramic primer (silane containing) seems to perform better than the three-step etch and rinse adhesive or the Composite primer. Shear-type stress had an adverse effect on the repair bond strength of bulk-fill resin composites.