Comparison of dental flosses - an investigation of subjective preference and mechanical properties.

Biomaterial investigations in dentistry Pub Date : 2023-09-22 eCollection Date: 2023-01-01 DOI:10.1080/26415275.2023.2258919
Zhongjin Huang, Jonathan M Broadbent, Joanne Jung Eun Choi
{"title":"Comparison of dental flosses - an investigation of subjective preference and mechanical properties.","authors":"Zhongjin Huang,&nbsp;Jonathan M Broadbent,&nbsp;Joanne Jung Eun Choi","doi":"10.1080/26415275.2023.2258919","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the properties (tensile strength, roughness, abrasiveness) of different dental flosses and how these properties relate to subjective preference for floss by users.</p><p><strong>Materials and method: </strong>Four flosses of differing compositions were selected (polytetrafluoroethylene (PTFE), nylon, silk, and ultra-high-molecular-weight polyethylene (UHMWPE)). Tensile strength (TS) was measured utilising a universal testing machine (total <i>n</i> = 40). Surface roughness (Ra) was measured on 3D reconstructed models of scanning electron microscope and abrasiveness was measured through block-on-ring tests against human enamel. Subjective preference for floss was measured by asking a sample of 16 individuals to use each floss for an 8-day period using a split-mouth design.</p><p><strong>Results: </strong>The highest TS was found in UHMWPE floss (194.18<math><mo>±</mo></math>24.61 MPa) while the lowest TS was found in PTFE floss (11.78<math><mo>±</mo></math>0.77 MPa). Silk floss had the highest Ra (0.304<math><mo>±</mo></math>0.025 <i>µ</i>m) while PTFE floss had the lowest (0.048<math><mo>±</mo></math>0.003 <i>µ</i>m). In-vitro abrasion testing of the flosses identified no significant differences between the flosses in causing wear on tooth enamel. Subjective ratings of flosses indicated PTFE floss to be most preferred and nylon floss to be least preferred.</p><p><strong>Conclusion: </strong>There was a difference in subjective preference between dental flosses composed of different materials. The PTFE floss was the overall most preferred while the nylon floss was the least preferred. There was also an association between the mechanical properties and preference for their usage, with PTFE floss being the most preferred but having the lowest surface roughness and tensile strength.</p><p><strong>Clinical relevance: </strong>This study compared a wide range of mechanical properties and subject preferences of commercially available dental floss. The results of this study can provide guidance for the recommendation of dental floss for oral hygiene routines.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":"10 1","pages":"2258919"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a7/33/IABO_10_2258919.PMC10519255.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/26415275.2023.2258919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the properties (tensile strength, roughness, abrasiveness) of different dental flosses and how these properties relate to subjective preference for floss by users.

Materials and method: Four flosses of differing compositions were selected (polytetrafluoroethylene (PTFE), nylon, silk, and ultra-high-molecular-weight polyethylene (UHMWPE)). Tensile strength (TS) was measured utilising a universal testing machine (total n = 40). Surface roughness (Ra) was measured on 3D reconstructed models of scanning electron microscope and abrasiveness was measured through block-on-ring tests against human enamel. Subjective preference for floss was measured by asking a sample of 16 individuals to use each floss for an 8-day period using a split-mouth design.

Results: The highest TS was found in UHMWPE floss (194.18±24.61 MPa) while the lowest TS was found in PTFE floss (11.78±0.77 MPa). Silk floss had the highest Ra (0.304±0.025 µm) while PTFE floss had the lowest (0.048±0.003 µm). In-vitro abrasion testing of the flosses identified no significant differences between the flosses in causing wear on tooth enamel. Subjective ratings of flosses indicated PTFE floss to be most preferred and nylon floss to be least preferred.

Conclusion: There was a difference in subjective preference between dental flosses composed of different materials. The PTFE floss was the overall most preferred while the nylon floss was the least preferred. There was also an association between the mechanical properties and preference for their usage, with PTFE floss being the most preferred but having the lowest surface roughness and tensile strength.

Clinical relevance: This study compared a wide range of mechanical properties and subject preferences of commercially available dental floss. The results of this study can provide guidance for the recommendation of dental floss for oral hygiene routines.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
牙线的比较——主观偏好和机械性能的调查。
目的:研究不同牙线的性能(抗拉强度、粗糙度、耐磨性),以及这些性能与使用者对牙线的主观偏好之间的关系。材料和方法:选择四种不同成分的浮丝(聚四氟乙烯(PTFE)、尼龙、丝绸和超高分子量聚乙烯(UHMWPE))。使用通用试验机测量抗拉强度(TS)(总n = 40)。在扫描电子显微镜的3D重建模型上测量表面粗糙度(Ra),并通过对人类牙釉质的块对环测试来测量磨损性。通过要求16个人的样本使用每种牙线8天,使用开口设计来测量对牙线的主观偏好。结果:超高分子量聚乙烯牙线TS最高(194.18±24.61) MPa),而PTFE牙线的TS最低(11.78±0.77 MPa)。丝线的Ra最高(0.304±0.025 µm),而PTFE牙线的含量最低(0.048±0.003 µm)。牙线的体外磨损测试表明,牙线在引起牙釉质磨损方面没有显著差异。牙线的主观评级表明PTFE牙线是最优选的,尼龙牙线是最低优选的。结论:不同材料的牙线在主观偏好上存在差异。PTFE牙线总体上是最优选的,而尼龙牙线是最不优选的。机械性能和对其使用的偏好之间也存在关联,PTFE牙线是最优选的,但具有最低的表面粗糙度和拉伸强度。临床相关性:本研究比较了商用牙线的广泛机械性能和受试者偏好。这项研究的结果可以为推荐牙线用于口腔卫生常规提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
期刊最新文献
Root-filling materials for endodontic surgery: biological and clinical aspects. Silane and acid etch cross contamination of dentin and composite reduced µ-tensile bond strength. Recipient of Biomaterial Investigations in Dentistry's Young Author Award 2023. Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction. The sealing ability of different endodontic biomaterials as an intra-orifice barrier: evaluation with high-performance liquid chromatography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1