NIST Spectroscopic Measurement Standards.

IF 0.1 4区 医学 Q4 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Biopharm International Pub Date : 2018-01-01
Kenneth D Cole, Paul DeRose, Hua-Jun He, Erica V Stein, Brian Lang, John Schiel, Aaron Urbas, Evelyn Solis, Steve Choquette
{"title":"NIST Spectroscopic Measurement Standards.","authors":"Kenneth D Cole,&nbsp;Paul DeRose,&nbsp;Hua-Jun He,&nbsp;Erica V Stein,&nbsp;Brian Lang,&nbsp;John Schiel,&nbsp;Aaron Urbas,&nbsp;Evelyn Solis,&nbsp;Steve Choquette","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Ultraviolet (UV) absorbance measurements provide a rapid and reliable method to determine protein concentrations. the National Institute of standards and technology (NIST) has developed <i>Standard Reference Material (SRM) 2082</i> as a pathlength standard for UV absorbance measurements for use with the new generation of microvolume spectrophotometers and short-pathlength cuvettes. short pathlengths are used with high-concentration targets to ensure that absorbance values are within the optimal range. the short-pathlength instruments and cuvettes also reduce the required volumes to conserve valuable samples. the authors compared the results obtained with high-quality dual-beam spectrophotometers and short-pathlength cuvettes to the results obtained from a microvolume spectrophotometer and a microvolume plate reader. SRM 2082 can be used to accurately calculate pathlength values, thereby increasing the accuracy in subsequent measurements using the short-pathlength cuvettes and microvolume absorbance instruments. RM 8671 (reference material, the NISTmAb) can then be used to ensure the accuracy and reproducibility of protein concentration measurements by providing an industrially relevant reference material, a well-characterized monoclonal antibody.</p>","PeriodicalId":55359,"journal":{"name":"Biopharm International","volume":"31 4","pages":"22-34"},"PeriodicalIF":0.1000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6463315/pdf/nihms-990019.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biopharm International","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Ultraviolet (UV) absorbance measurements provide a rapid and reliable method to determine protein concentrations. the National Institute of standards and technology (NIST) has developed Standard Reference Material (SRM) 2082 as a pathlength standard for UV absorbance measurements for use with the new generation of microvolume spectrophotometers and short-pathlength cuvettes. short pathlengths are used with high-concentration targets to ensure that absorbance values are within the optimal range. the short-pathlength instruments and cuvettes also reduce the required volumes to conserve valuable samples. the authors compared the results obtained with high-quality dual-beam spectrophotometers and short-pathlength cuvettes to the results obtained from a microvolume spectrophotometer and a microvolume plate reader. SRM 2082 can be used to accurately calculate pathlength values, thereby increasing the accuracy in subsequent measurements using the short-pathlength cuvettes and microvolume absorbance instruments. RM 8671 (reference material, the NISTmAb) can then be used to ensure the accuracy and reproducibility of protein concentration measurements by providing an industrially relevant reference material, a well-characterized monoclonal antibody.

Abstract Image

Abstract Image

Abstract Image

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
NIST光谱测量标准。
紫外(UV)吸光度测量提供了一种快速可靠的方法来测定蛋白质浓度。美国国家标准与技术研究所(NIST)已经开发了标准参考材料(SRM)2082,作为与新一代微体积分光光度计和短路径长度比色皿一起使用的UV吸收测量的路径长度标准。短路径长度与高浓度靶标一起使用,以确保吸光度值在最佳范围内。短路径长度的仪器和比色皿也减少了保存有价值样品所需的体积。作者将高质量的双光束分光光度计和短光程比色杯获得的结果与微体积分光光度仪和微体积读板器获得的结果进行了比较。SRM 2082可用于精确计算路径长度值,从而提高使用短路径长度比色皿和微容吸收仪器进行后续测量的准确性。RM 8671(参考材料,NISTmAb)然后可以用于通过提供工业上相关的参考材料,即表征良好的单克隆抗体来确保蛋白质浓度测量的准确性和再现性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biopharm International
Biopharm International 医学-生物工程与应用微生物
CiteScore
0.30
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: BioPharm International integrates the science and business of biopharmaceuticals, covering all aspects of biopharmaceutical research, development, formulation, analysis, upstream and downstream processing, manufacturing, supply chain, and packaging, as well as business strategies and regulatory issues.
期刊最新文献
NIST Spectroscopic Measurement Standards.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1