Optimized Attachment to Achieve Different Buccolingual Movement of Maxillary Molars in Clear Aligner Orthodontic System: Biomechanical Analysis

Long Qin, Qiao Wang, Dongliang Zhang, Xin He, Binbin Wu
{"title":"Optimized Attachment to Achieve Different Buccolingual Movement of Maxillary Molars in Clear Aligner Orthodontic System: Biomechanical Analysis","authors":"Long Qin, Qiao Wang, Dongliang Zhang, Xin He, Binbin Wu","doi":"10.1166/NNL.2020.3151","DOIUrl":null,"url":null,"abstract":"The different positions and angles of attachment affecting the buccolingual movement of the maxillary molars, especially lingual tipping and negative torque movements, were biomechanically analyzed in order to determine how to better control and prevent unwanted movement of clear aligners.\n The aligner can be designed and placed appropriately to improve expected tooth movement. Based on mechanical principles, the force system of attachment was analyzed, and the optimum attachment position and angle for tipping and negative torque movement was determined. Attachment close to the\n enamel-cementum junction (ECJ) was found to achieve the best F (M/L) during negative torque movement; however, the angle should also be adjusted. Attachment close to the occlusal surface achieved greater tipping force at specific angles. When more tipping movement is required, it is recommended\n to place the attachment 3–5 mm from the ECJ. The angle of the attachment should be 110–120 degrees from the tooth surface. When place the attachment 4–5 mm from the ECJ, the angle of the attachment should be between 145 and 146.5 degrees.","PeriodicalId":18871,"journal":{"name":"Nanoscience and Nanotechnology Letters","volume":"12 1","pages":"1249-1254"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscience and Nanotechnology Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/NNL.2020.3151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The different positions and angles of attachment affecting the buccolingual movement of the maxillary molars, especially lingual tipping and negative torque movements, were biomechanically analyzed in order to determine how to better control and prevent unwanted movement of clear aligners. The aligner can be designed and placed appropriately to improve expected tooth movement. Based on mechanical principles, the force system of attachment was analyzed, and the optimum attachment position and angle for tipping and negative torque movement was determined. Attachment close to the enamel-cementum junction (ECJ) was found to achieve the best F (M/L) during negative torque movement; however, the angle should also be adjusted. Attachment close to the occlusal surface achieved greater tipping force at specific angles. When more tipping movement is required, it is recommended to place the attachment 3–5 mm from the ECJ. The angle of the attachment should be 110–120 degrees from the tooth surface. When place the attachment 4–5 mm from the ECJ, the angle of the attachment should be between 145 and 146.5 degrees.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
优化附着体实现上颌磨牙不同颊舌运动:生物力学分析
对影响上颌磨牙颊舌运动的不同附着位置和角度,特别是舌侧倾斜和负扭矩运动进行了生物力学分析,以确定如何更好地控制和防止透明矫正器的不必要运动。对准器可以适当地设计和放置,以改善预期的牙齿运动。基于力学原理,分析了附着体的受力系统,确定了倾翻和负力矩运动的最佳附着位置和角度。研究发现,在负扭矩运动过程中,靠近牙釉质-牙骨质连接处(ECJ)的附着物可获得最佳的F(M/L);但是,也应该调整角度。靠近咬合表面的附着在特定角度下获得了更大的倾翻力。当需要更多的倾翻运动时,建议将附件放置在距离ECJ 3-5 mm的位置。附件与齿面的夹角应为110–120度。当将附件放置在距离ECJ 4–5 mm的位置时,附件的角度应在145度和146.5度之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Nanoscience and Nanotechnology Letters
Nanoscience and Nanotechnology Letters Physical, Chemical & Earth Sciences-MATERIALS SCIENCE, MULTIDISCIPLINARY
自引率
0.00%
发文量
0
审稿时长
2.6 months
期刊最新文献
Identification of Immune-Related Prognostic Biomarkers in Pancreatic Cancer Nanocomposite Detection of Elemental Impurities and Process Correlation Analysis of Ceftriaxone Sodium for Injection Astragalus Polysaccharide Nano-Liposomes Modulate the Inflammatory Response and Oxidative Stress in Stroke-Associated Pneumonia by Increasing OIP5-AS1 to Regulate the miR-128-3p/SIRT1 Pathway miR-199a-3p Inhibitor Delivered Through Nano-Drug Delivery Systems Suppresses Tumor Cell Survival and Metastasis Construction of Functional Renal Targeting Nano Drug Liposome and Its Effect on Lupus Nephritis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1