Remote investigation and assessment of vital signs (RIA-VS)—proof of concept for contactless estimation of blood pressure, pulse, respiratory rate, and oxygen saturation in patients with suspicion of COVID-19

IF 4 4区 医学 Q1 INFECTIOUS DISEASES Infectious Diseases Pub Date : 2022-06-01 DOI:10.1080/23744235.2022.2080249
Stefan Malmberg, Taha Khan, R. Gunnarsson, Gunnar Jacobsson, Pär-Daniel Sundvall
{"title":"Remote investigation and assessment of vital signs (RIA-VS)—proof of concept for contactless estimation of blood pressure, pulse, respiratory rate, and oxygen saturation in patients with suspicion of COVID-19","authors":"Stefan Malmberg, Taha Khan, R. Gunnarsson, Gunnar Jacobsson, Pär-Daniel Sundvall","doi":"10.1080/23744235.2022.2080249","DOIUrl":null,"url":null,"abstract":"Abstract Background Vital signs are critical in assessing the severity and prognosis of infections, for example, COVID-19, influenza, sepsis, and pneumonia. This study aimed to evaluate a new method for rapid camera-based non-contact measurement of heart rate, blood oxygen saturation, respiratory rate, and blood pressure. Methods Consecutive adult patients attending a hospital emergency department for suspected COVID-19 infection were invited to participate. Vital signs measured with a new camera-based method were compared to the corresponding standard reference methods. The camera device observed the patient's face for 30 s from ∼1 m. Results Between 1 April and 1 October 2020, 214 subjects were included in the trial, 131 female (61%) and 83 male (39%). The mean age was 44 years (range 18–81 years). The new camera-based device’s vital signs measurements were, on average, very close to the gold standard but the random variation was larger than the reference methods. Conclusions The principle of contactless measurement of blood pressure, pulse, respiratory rate, and oxygen saturation works, which is very promising. However, technical improvements to the equipment used in this study to reduce its random variability is required before clinical implementation. This will likely be a game changer once this is sorted out. Clinical trial registration Universal Trial Number (UTN) U1111-1251-4114 and the ClinicalTrials.gov Identifier NCT04383457.","PeriodicalId":13671,"journal":{"name":"Infectious Diseases","volume":"54 1","pages":"677 - 686"},"PeriodicalIF":4.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/23744235.2022.2080249","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background Vital signs are critical in assessing the severity and prognosis of infections, for example, COVID-19, influenza, sepsis, and pneumonia. This study aimed to evaluate a new method for rapid camera-based non-contact measurement of heart rate, blood oxygen saturation, respiratory rate, and blood pressure. Methods Consecutive adult patients attending a hospital emergency department for suspected COVID-19 infection were invited to participate. Vital signs measured with a new camera-based method were compared to the corresponding standard reference methods. The camera device observed the patient's face for 30 s from ∼1 m. Results Between 1 April and 1 October 2020, 214 subjects were included in the trial, 131 female (61%) and 83 male (39%). The mean age was 44 years (range 18–81 years). The new camera-based device’s vital signs measurements were, on average, very close to the gold standard but the random variation was larger than the reference methods. Conclusions The principle of contactless measurement of blood pressure, pulse, respiratory rate, and oxygen saturation works, which is very promising. However, technical improvements to the equipment used in this study to reduce its random variability is required before clinical implementation. This will likely be a game changer once this is sorted out. Clinical trial registration Universal Trial Number (UTN) U1111-1251-4114 and the ClinicalTrials.gov Identifier NCT04383457.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生命体征远程调查和评估(RIA-VS)——用于对疑似COVID-19患者的血压、脉搏、呼吸频率和血氧饱和度进行非接触式评估的概念验证
摘要背景生命体征对于评估感染的严重程度和预后至关重要,例如新冠肺炎、流感、败血症和肺炎。本研究旨在评估一种基于摄像头的心率、血氧饱和度、呼吸频率和血压非接触式快速测量新方法。方法邀请连续到医院急诊科就诊的疑似新冠肺炎感染的成年患者参加。用一种新的基于摄像头的方法测量的生命体征与相应的标准参考方法进行了比较。摄像设备观察患者面部30分钟 结果在2020年4月1日至10月1日期间,214名受试者被纳入试验,其中131名女性(61%),83名男性(39%)。平均年龄44岁 年(范围18-81 年)。这种新的基于摄像头的设备的生命体征测量结果平均非常接近金标准,但随机变化比参考方法更大。结论非接触式测量血压、脉搏、呼吸频率和血氧饱和度的原理是可行的,非常有前景。然而,在临床实施之前,需要对本研究中使用的设备进行技术改进,以减少其随机变异性。一旦问题解决,这很可能会改变游戏规则。临床试验注册通用试验编号(UTN)U1111-1251-4114和ClinicalTrials.gov标识符NCT04383457。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Infectious Diseases
Infectious Diseases INFECTIOUS DISEASES-
CiteScore
8.20
自引率
1.70%
发文量
92
审稿时长
8 weeks
期刊介绍: Infectious Diseases (formerly Scandinavian Journal of Infectious Diseases) is a peer-reviewed journal publishing articles on all aspects of human infection, including pathogenesis, diagnosis, and treatment of infectious diseases, and also on medical microbiology and epidemiology
期刊最新文献
The silent invaders: Oropouche and Melao viruses, causes of increased public health risks for the Americas. Evaluation of the 2023 Duke-ISCVID criteria for infective endocarditis in patients referred to the Lund infective endocarditis team. Clinical evaluation of a highly multiplexed CRISPR-based diagnostic assay for diagnosing lower respiratory tract infection: a prospective cohort study. First cases of mpox Clade I outside of Africa: genetic insights on its evolution. Trends in decision-making by primary care physicians regarding common infectious complaints
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1