Validity and reliability of ergonauta encoder to assess countermovement jump performance

R. Gheller, R. Kons, Wladymir Külkamp, J. Dal Pupo, D. Detanico
{"title":"Validity and reliability of ergonauta encoder to assess countermovement jump performance","authors":"R. Gheller, R. Kons, Wladymir Külkamp, J. Dal Pupo, D. Detanico","doi":"10.1177/17543371231171192","DOIUrl":null,"url":null,"abstract":"This study aimed to test the reliability and criterion validity of the Ergonauta encoder to assess countermovement jump (CMJ) performance, considering jump height and mean propulsive velocity metrics. Twenty-three recreationally active men participated in this study. The participants were positioned on a force plate with the Ergonauta individually connected through a belt. Two CMJs were performed, and the jump height and mean propulsive velocity metrics were analyzed. The intraclass correlation coefficient (ICC) and typical error (TE) were used as relative and absolute reliability indicators, respectively. The Pearson correlation was used to verify the relationship between the Ergonauta and force plate derived-metrics, and the Bland-Altman plot was used to verify the agreement between the metrics ( Ergonauta encoder and force plate), with the level of significance set at p < 0.05. The results show excellent relative reliability for both metrics, considering the two evaluation devices (ICC = 0.95–0.99, TE = 1.02–2.46). The jump height and mean propulsive velocity obtained by the Ergonauta encoder and the force plate were strongly correlated ( r = 0.95; r = 0.90, respectively, p < 0.01). The Bland-Altman plot showed good agreement for both metrics (jump height and mean propulsive power) and equipment (close to 0). We concluded that the Ergonauta encoder is reliable and valid for assessing CMJ performance, particularly the jump height and mean propulsive velocity metrics.","PeriodicalId":20674,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","volume":"1 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17543371231171192","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to test the reliability and criterion validity of the Ergonauta encoder to assess countermovement jump (CMJ) performance, considering jump height and mean propulsive velocity metrics. Twenty-three recreationally active men participated in this study. The participants were positioned on a force plate with the Ergonauta individually connected through a belt. Two CMJs were performed, and the jump height and mean propulsive velocity metrics were analyzed. The intraclass correlation coefficient (ICC) and typical error (TE) were used as relative and absolute reliability indicators, respectively. The Pearson correlation was used to verify the relationship between the Ergonauta and force plate derived-metrics, and the Bland-Altman plot was used to verify the agreement between the metrics ( Ergonauta encoder and force plate), with the level of significance set at p < 0.05. The results show excellent relative reliability for both metrics, considering the two evaluation devices (ICC = 0.95–0.99, TE = 1.02–2.46). The jump height and mean propulsive velocity obtained by the Ergonauta encoder and the force plate were strongly correlated ( r = 0.95; r = 0.90, respectively, p < 0.01). The Bland-Altman plot showed good agreement for both metrics (jump height and mean propulsive power) and equipment (close to 0). We concluded that the Ergonauta encoder is reliable and valid for assessing CMJ performance, particularly the jump height and mean propulsive velocity metrics.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机器人编码器评估反向跳跃性能的有效性和可靠性
本研究旨在测试Ergonauta编码器的可靠性和标准有效性,以评估反跳(CMJ)性能,同时考虑跳跃高度和平均推进速度指标。23名活跃于娱乐活动的男性参与了这项研究。参与者被安置在一个力板上,Ergonauta通过一条皮带单独连接。进行了两次CMJ,并对跳跃高度和平均推进速度指标进行了分析。组内相关系数(ICC)和典型误差(TE)分别用作相对和绝对可靠性指标。Pearson相关性用于验证Ergonauta和力板衍生指标之间的关系,Bland-Altman图用于验证指标(Ergonauda编码器和力板)之间的一致性,显著性水平设置为p < 0.05。考虑到两种评估设备(ICC = 0.95–0.99,TE = 1.02–2.46)。通过Ergonauta编码器和力板获得的跳跃高度和平均推进速度强相关(r = 0.95;r = 分别为0.90,p < Bland-Altman图在两个指标(跳跃高度和平均推进力)和设备(接近0)方面显示出良好的一致性。我们得出的结论是,Ergonauta编码器在评估CMJ性能方面是可靠和有效的,特别是跳跃高度和平均推进速度指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
20.00%
发文量
51
审稿时长
>12 weeks
期刊介绍: The Journal of Sports Engineering and Technology covers the development of novel sports apparel, footwear, and equipment; and the materials, instrumentation, and processes that make advances in sports possible.
期刊最新文献
Effects of training repetition on young footballers’ tactical and physical performances: free and conditioned large-sided games A single trunk-mounted wearable sensor to measure motor performance in triathletes during competition The effectiveness of chalk as a friction modifier for finger pad contact with rocks of varying roughness In-plane density gradation of shoe midsoles for optimal energy absorption performance Development of a video-based test for assessing decision-making proficiency in football referees
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1