A technique for anchor plug salvage in the setting of a cold welded taper adapter following compress implant failure

IF 0.5 4区 医学 Q4 ORTHOPEDICS Annals of Joint Pub Date : 2019-08-27 DOI:10.21037/aoj.2019.08.01
S. Campbell, Allison K. Roe, R. Avedian
{"title":"A technique for anchor plug salvage in the setting of a cold welded taper adapter following compress implant failure","authors":"S. Campbell, Allison K. Roe, R. Avedian","doi":"10.21037/aoj.2019.08.01","DOIUrl":null,"url":null,"abstract":"The Compress implant is used to achieve compliant fixation for endoprosthetic reconstruction during limb salvage. Failures, when they occur, are typically at the bone-implant interface. We describe a case of implant failure at a modular junction near a cold-welded taper adapter, blocking access to the spindle nut. Salvage of the anchor plug was performed in this case to avoid re-cutting the remaining bone.","PeriodicalId":44459,"journal":{"name":"Annals of Joint","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2019-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.21037/aoj.2019.08.01","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Joint","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/aoj.2019.08.01","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

The Compress implant is used to achieve compliant fixation for endoprosthetic reconstruction during limb salvage. Failures, when they occur, are typically at the bone-implant interface. We describe a case of implant failure at a modular junction near a cold-welded taper adapter, blocking access to the spindle nut. Salvage of the anchor plug was performed in this case to avoid re-cutting the remaining bone.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
压缩植入失败后冷焊锥形适配器设置中的锚栓打捞技术
压缩植入物用于在保肢过程中实现顺应性固定,用于内修复。当发生故障时,通常发生在骨-植入物界面。我们描述了一个植入物在冷焊锥形适配器附近的模块化连接处发生故障,阻塞了对主轴螺母的访问。在这种情况下进行了锚栓的打捞,以避免再次切割剩余的骨头。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Joint
Annals of Joint ORTHOPEDICS-
CiteScore
1.10
自引率
-25.00%
发文量
17
期刊最新文献
The role of anterolateral complex surgery and slope-reducing osteotomies in revision ACL reconstructions: a narrative review. Three- or four-part proximal humeral fractures in middle-aged and active elderly group of patients: a narrative review of treatment options. Weightlessness damaged the ultrastructure of knee cartilage and quadriceps muscle, aggravated the degeneration of cartilage. Diagnostic strategies for chronic lateral ankle instability: a narrative review. Bone loss in shoulder instability and shoulder arthroplasty.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1