COMPARISON OF ANALYTIC PERFORMANCE OF RESULTS OF DETERMINATION OF Pb METAL IONS USING ATOMIC ABSORPTION SPECTROPHOTOMETER of VARIOUS in SAMARINDA LABORATORIES

Arifin Syam Surya, Bohari Yusuf, A. S. Panggabean
{"title":"COMPARISON OF ANALYTIC PERFORMANCE OF RESULTS OF DETERMINATION OF Pb METAL IONS USING ATOMIC ABSORPTION SPECTROPHOTOMETER of VARIOUS in SAMARINDA LABORATORIES","authors":"Arifin Syam Surya, Bohari Yusuf, A. S. Panggabean","doi":"10.30872/jkm.v19i1.909","DOIUrl":null,"url":null,"abstract":"The study about the comparison of analytical performance of the determination of Pb metal ions using Atomic Absorption Spectrophotometer in various laboratories in samarinda has been conducted. The validated methods are linearity, detection limits, quantity and precision limits. The results showed, a standardized regression test obtained by laboratory A, a value of R2 ≥ 0.4103, laboratory B a value of R2 ≥ 0.983 and laboratory C, a value of R2 ≥ 0.000. The detection limit found at laboratory A was 0.6728 µg/L, laboratory B was 0.1989 µg/L and laboratory C was 0.0001 µg/L. The quantization limit obtained by laboratory A was 0.6817 µg/L, laboratory B was 0.6063 µg/L and laboratory C was 0.0001 µg/L. The precision test of laboratory A was 7.2208, laboratory B was 5.4557 and laboratory C was 0,000. The result of determining Pb of gas station soil samples in laboratory A is 0.737 µg/L and laboratory B is 0.391 µg/L, so that means they have exceeded the quality standards set by the Indonesian National Standard (INS).","PeriodicalId":31725,"journal":{"name":"Jurnal Kimia Mulawarman","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kimia Mulawarman","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30872/jkm.v19i1.909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The study about the comparison of analytical performance of the determination of Pb metal ions using Atomic Absorption Spectrophotometer in various laboratories in samarinda has been conducted. The validated methods are linearity, detection limits, quantity and precision limits. The results showed, a standardized regression test obtained by laboratory A, a value of R2 ≥ 0.4103, laboratory B a value of R2 ≥ 0.983 and laboratory C, a value of R2 ≥ 0.000. The detection limit found at laboratory A was 0.6728 µg/L, laboratory B was 0.1989 µg/L and laboratory C was 0.0001 µg/L. The quantization limit obtained by laboratory A was 0.6817 µg/L, laboratory B was 0.6063 µg/L and laboratory C was 0.0001 µg/L. The precision test of laboratory A was 7.2208, laboratory B was 5.4557 and laboratory C was 0,000. The result of determining Pb of gas station soil samples in laboratory A is 0.737 µg/L and laboratory B is 0.391 µg/L, so that means they have exceeded the quality standards set by the Indonesian National Standard (INS).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同实验室原子吸收分光光度计测定铅金属离子结果的分析性能比较
对萨马林达市各实验室原子吸收分光光度法测定铅金属离子的分析性能进行了比较研究。验证方法有线性度、检出限、数量限和精密度限。结果表明,实验室a的标准化回归检验值为R2 ‰0.4103,实验室B的标准化回归检验值为R2 ‰0.983,实验室C的标准化回归检验值为R2 ‰0.000。实验室A的检出限为0.6728 µg/L,实验室B的检出限为0.1989 µg/L,实验室C的检出限为0.0001 µg/L。实验室A的定量限为0.6817 µg/L,实验室B为0.6063 µg/L,实验室C为0.0001 µg/L。实验室A精密度测试为7.2208,实验室B精密度测试为5.4557,实验室C精密度测试为0000。A实验室对加油站土壤样品的Pb测定结果为0.737 µg/L, B实验室的Pb测定结果为0.391 µg/L,超出了印尼国家标准(INS)的质量标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
3
审稿时长
16 weeks
期刊最新文献
Pengujian Toksisitas dan Antioksidan Ekstrak Etilasetat dan n-Butanol Hipokotil Sarang Semut, Myrmecodia pendens Merr. & Perry Anti-Inflammatory Effect Of Extract And Fractions Of Gaharu (Aquilaria malaccensis Lamk.) Leaves Determination of Secondary Compounds in Extracts from Catfish (Pangasius sp) Formulation And Physical Stability Test Of Mother-In-Law’s Tongue Leaves Extract Lotion As An Antioxidant Active Compounds of Sembung Leaves (Blumea balsamifera DC) in Silico Screening as Antihypertensives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1