Diagnostic Reference Level in Frontal Chest X-Ray in Western Côte d’Ivoire

I. Konaté, G. A. Monnehan, Douo B. L. H. Gogon, T. Dali, A. A. Koua, K. Djagouri
{"title":"Diagnostic Reference Level in Frontal Chest X-Ray in Western Côte d’Ivoire","authors":"I. Konaté, G. A. Monnehan, Douo B. L. H. Gogon, T. Dali, A. A. Koua, K. Djagouri","doi":"10.4236/wjnst.2019.94011","DOIUrl":null,"url":null,"abstract":"Our study aims to determine diagnostic reference levels (DRL) for chest front examination in postero anterior (PA) for optimizing patient entrance surface dose (ESD) and dose-area product (DAP) of patients in west of Cote d’Ivoire. 90 patients from three hospitals undergoing conventional radiology were considered. The ESD and DAP for each patient were obtained during chest radiography (PA) examination. The measurements were performed with the device call Dose-Area Product-meter (DAP-meter) with brand Diamentor M4-KDK, type 11017. The DRL were obtained in applying the 75th percentile statistical method to the obtained ESD and DAP. The obtained DRL in ESD for chest radiography for all rooms is 0.40 mGy and in DAP is 54.85 cGy⋅cm2. Our DRL for ESD is higher than those obtained in Abidjan District and in other countries like UK and Cameroon. Our DRL for DAP is higher than those from Abidjan and all other countries for which a similar study was made. The comparison of these values to those from Abidjan and other countries, shows us that radiology technicians can make efforts to choose radiological parameters to reduce ESD. They must use convenable the X-rays tube to reduce DAP by reducing the patient exposure surface.","PeriodicalId":61566,"journal":{"name":"核科学与技术国际期刊(英文)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"核科学与技术国际期刊(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.4236/wjnst.2019.94011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Our study aims to determine diagnostic reference levels (DRL) for chest front examination in postero anterior (PA) for optimizing patient entrance surface dose (ESD) and dose-area product (DAP) of patients in west of Cote d’Ivoire. 90 patients from three hospitals undergoing conventional radiology were considered. The ESD and DAP for each patient were obtained during chest radiography (PA) examination. The measurements were performed with the device call Dose-Area Product-meter (DAP-meter) with brand Diamentor M4-KDK, type 11017. The DRL were obtained in applying the 75th percentile statistical method to the obtained ESD and DAP. The obtained DRL in ESD for chest radiography for all rooms is 0.40 mGy and in DAP is 54.85 cGy⋅cm2. Our DRL for ESD is higher than those obtained in Abidjan District and in other countries like UK and Cameroon. Our DRL for DAP is higher than those from Abidjan and all other countries for which a similar study was made. The comparison of these values to those from Abidjan and other countries, shows us that radiology technicians can make efforts to choose radiological parameters to reduce ESD. They must use convenable the X-rays tube to reduce DAP by reducing the patient exposure surface.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
西部Côte科特迪瓦胸部x线诊断参考水平
本研究旨在确定后前路(PA)胸前检查的诊断参考水平(DRL),以优化科特迪瓦西部患者的患者入口表面剂量(ESD)和剂量面积积(DAP)。对来自三家医院接受常规放射检查的90名患者进行了研究。在胸片(PA)检查时获得每位患者的ESD和DAP。使用Diamentor M4-KDK(11017型)品牌的剂量面积产品计(DAP-meter)进行测量。对所得的ESD和DAP采用75百分位统计方法计算DRL。所有房间胸片在ESD下的DRL为0.40 mGy,在DAP下的DRL为54.85 cGy·cm2。我们的可持续发展教育DRL高于阿比让地区以及英国和喀麦隆等其他国家的DRL。我们对DAP的DRL高于阿比让和所有其他进行类似研究的国家。这些数值与阿比让和其他国家的数值比较,表明放射技术人员可以努力选择放射参数来降低ESD。他们必须使用方便的x射线管,通过减少患者的暴露面来减少DAP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
198
期刊最新文献
System Variables Design of Safety Analysis for Fast Reactors Numerical Analysis of Heating Technique in Corium Melt Pool Convection Flow Field & Thermal Interaction in a Volumetrically Heated Molten Pool Feasibility to Convert the NuScale SMR from UO2 to a Mixed (U, Th)O2 Core: A Parametric Study of Fuel Element—Seed-Blanket Concept Cause Analysis for Wall Thinning of Small-Bore Piping in Nuclear Power Plant by ToSPACE, FLUENT and Theoretical Evaluation The Systematics Study of (n, p) Reaction Cross-Sections at 14.7 MeV Neutron Energy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1