A power quality enhanced for the wind turbine with sensorless direct power control under different input voltage conditions

IF 1.6 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Electrical Engineering & Electromechanics Pub Date : 2021-12-03 DOI:10.20998/2074-272x.2021.6.09
Zakaria Laggoun, H. Benalla, K. Nebti
{"title":"A power quality enhanced for the wind turbine with sensorless direct power control under different input voltage conditions","authors":"Zakaria Laggoun, H. Benalla, K. Nebti","doi":"10.20998/2074-272x.2021.6.09","DOIUrl":null,"url":null,"abstract":"Introduction. The quality of electrical energy is essential during disturbances, at the level of power electronic devices will suffer serious operating problems causing dangerous damage. Aim. A new approach to direct power control without grid voltage sensor improves the quality and control of instantaneous active and reactive power converters. Methodology. First, the technique without network voltage sensor with a direct power control based on a switching table, which is a classic approach, is discussed and its performance is analyzed under increasing and decreasing load. In addition, the performance of the proposed technique is also analyzed under the same circumstances and their performance is compared. Originality. The new method consists of a nonlinear grid voltage modulated controller and a conventional controller which guarantees very good results in a polluted network. The proposed method is verified using MATLAB/Simulink. Results. The simulation results under different input voltage conditions show that the proposed method not only has good tracking performance in active and reactive power, but also reduces the current total harmonic distortion to 1.9 %, which is good lower than the requirement for network operation.","PeriodicalId":44198,"journal":{"name":"Electrical Engineering & Electromechanics","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering & Electromechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2074-272x.2021.6.09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction. The quality of electrical energy is essential during disturbances, at the level of power electronic devices will suffer serious operating problems causing dangerous damage. Aim. A new approach to direct power control without grid voltage sensor improves the quality and control of instantaneous active and reactive power converters. Methodology. First, the technique without network voltage sensor with a direct power control based on a switching table, which is a classic approach, is discussed and its performance is analyzed under increasing and decreasing load. In addition, the performance of the proposed technique is also analyzed under the same circumstances and their performance is compared. Originality. The new method consists of a nonlinear grid voltage modulated controller and a conventional controller which guarantees very good results in a polluted network. The proposed method is verified using MATLAB/Simulink. Results. The simulation results under different input voltage conditions show that the proposed method not only has good tracking performance in active and reactive power, but also reduces the current total harmonic distortion to 1.9 %, which is good lower than the requirement for network operation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用无传感器直接功率控制提高了不同输入电压条件下风力发电机组的电能质量
介绍。电能的质量是至关重要的,在电力电子设备的扰动水平将遭受严重的运行问题,造成危险的损害。的目标。一种无需电网电压传感器的直接功率控制新方法提高了瞬时有功和无功变流器的质量和控制。方法。首先,讨论了经典的基于开关表的无网络电压传感器直接功率控制技术,并分析了该技术在负载增减条件下的性能。此外,还分析了在相同情况下所提出的技术的性能,并对其性能进行了比较。创意。该方法由一个非线性电网调压控制器和一个常规控制器组成,在污染网络中保证了很好的控制效果。利用MATLAB/Simulink对该方法进行了验证。结果。在不同输入电压条件下的仿真结果表明,该方法不仅具有良好的有功和无功跟踪性能,而且将电流总谐波失真降低到1.9%,较好地低于网络运行要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electrical Engineering & Electromechanics
Electrical Engineering & Electromechanics ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
50.00%
发文量
53
审稿时长
10 weeks
期刊最新文献
The mutual influence of exciting and induced currents in the circular solenoid – massive conductor system Current-voltage characteristics of single-stage semiconductor magnetic pulse generators with a distinctive structure of the conversion link in the input circuit Optimal hybrid photovoltaic distributed generation and distribution static synchronous compensators planning to minimize active power losses using adaptive acceleration coefficients particle swarm optimization algorithms Estimation of electrical resistivity of conductive materials of random shapes Modeling and research of a magnetoelectric converter for hydro and pneumo actuators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1