DL-EPR vs. LSV-KOH: from simple detection of deleterious phases to analysis of morphology and high accuracy on determination of sigma phase in UNS S32750 stainless steel
Marcelo T. G. de Sampaio, Anderson B. Furtado, M. Ignácio, S. Tavares, J. Pardal, A. Pimenta, E. Ponzio
{"title":"DL-EPR vs. LSV-KOH: from simple detection of deleterious phases to analysis of morphology and high accuracy on determination of sigma phase in UNS S32750 stainless steel","authors":"Marcelo T. G. de Sampaio, Anderson B. Furtado, M. Ignácio, S. Tavares, J. Pardal, A. Pimenta, E. Ponzio","doi":"10.1080/1478422X.2022.2128376","DOIUrl":null,"url":null,"abstract":"ABSTRACT An optimised electrochemical technique, linear sweep voltammetry (LSV) in KOH solution (LSV-KOH) was confronted with the double loop electrochemical Potentiokinetic reactivation (DL-EPR) to verify which is the best technique to quantify deleterious phases (DP) in a UNS S32750 super duplex stainless steel. DL-EPR presented an error in determination of deleterious phases in the range of 6.9–100%. LSV-KOH show a better accuracy in quantification of deleterious phases volume fractions, the error range for LSV-KOH was 2.4–26.2%. When the morphology of sigma changes from lamellar to divorced, was observed modifications on LSV-KOH voltammograms. In specimens where lamellar morphology is present, the voltammograms show two peaks curve. Meanwhile, in specimens where occurred also divorced precipitation of sigma the voltammograms changes to a 3 peaks curve. This feature is due to the dissolution of sigma phase boundaries which has different compositions according to the form of sigma precipitation.","PeriodicalId":10711,"journal":{"name":"Corrosion Engineering, Science and Technology","volume":"58 1","pages":"1 - 11"},"PeriodicalIF":1.5000,"publicationDate":"2022-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Engineering, Science and Technology","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1080/1478422X.2022.2128376","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
ABSTRACT An optimised electrochemical technique, linear sweep voltammetry (LSV) in KOH solution (LSV-KOH) was confronted with the double loop electrochemical Potentiokinetic reactivation (DL-EPR) to verify which is the best technique to quantify deleterious phases (DP) in a UNS S32750 super duplex stainless steel. DL-EPR presented an error in determination of deleterious phases in the range of 6.9–100%. LSV-KOH show a better accuracy in quantification of deleterious phases volume fractions, the error range for LSV-KOH was 2.4–26.2%. When the morphology of sigma changes from lamellar to divorced, was observed modifications on LSV-KOH voltammograms. In specimens where lamellar morphology is present, the voltammograms show two peaks curve. Meanwhile, in specimens where occurred also divorced precipitation of sigma the voltammograms changes to a 3 peaks curve. This feature is due to the dissolution of sigma phase boundaries which has different compositions according to the form of sigma precipitation.
期刊介绍:
Corrosion Engineering, Science and Technology provides broad international coverage of research and practice in corrosion processes and corrosion control. Peer-reviewed contributions address all aspects of corrosion engineering and corrosion science; there is strong emphasis on effective design and materials selection to combat corrosion and the journal carries failure case studies to further knowledge in these areas.