{"title":"Non-Special Loudspeakers as Speech Test Sources in Natural Acoustics Speech Intelligibility Investigations","authors":"L. Gomez-Agustina, H. Aygun, Liji Suseela Thankom Mohan","doi":"10.3390/acoustics5030038","DOIUrl":null,"url":null,"abstract":"Objective speech intelligibility estimations undertaken in natural acoustics speech communications (NAS) scenarios require the utilization of a speech source that approximates the acoustic characteristics of a human talker. Only a limited number of special speech sources that conform to the specifications in the relevant guidelines are available in the market; however, they can be deemed expensive by professional practitioners and other users. Non-special and affordable loudspeakers are often used in NAS investigations in place of standardized special speech sources without the knowledge of their suitability and results validity. This study aims to examine the suitability of a range of representative common and affordable non-special loudspeakers as a potential alternative to standardized speech sources in NAS indicative or pilot investigations. Frequency response and Speech Transmission Index Public Address (STIPA) experimental results obtained from a reference standardized speech source were compared against results from various non-special loudspeakers measured utilizing diverse and real-world representative combinations of NAS acoustic conditions under controlled laboratory conditions. STIPA mean absolute errors for the alternative speech sources were generally lower than the STIPA method uncertainty and one Just Noticeable Difference (0.03 STI). The findings of this study will inform practitioners of the suitability of affordable loudspeakers when standardized special test loudspeakers are not available.","PeriodicalId":72045,"journal":{"name":"Acoustics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustics (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/acoustics5030038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective speech intelligibility estimations undertaken in natural acoustics speech communications (NAS) scenarios require the utilization of a speech source that approximates the acoustic characteristics of a human talker. Only a limited number of special speech sources that conform to the specifications in the relevant guidelines are available in the market; however, they can be deemed expensive by professional practitioners and other users. Non-special and affordable loudspeakers are often used in NAS investigations in place of standardized special speech sources without the knowledge of their suitability and results validity. This study aims to examine the suitability of a range of representative common and affordable non-special loudspeakers as a potential alternative to standardized speech sources in NAS indicative or pilot investigations. Frequency response and Speech Transmission Index Public Address (STIPA) experimental results obtained from a reference standardized speech source were compared against results from various non-special loudspeakers measured utilizing diverse and real-world representative combinations of NAS acoustic conditions under controlled laboratory conditions. STIPA mean absolute errors for the alternative speech sources were generally lower than the STIPA method uncertainty and one Just Noticeable Difference (0.03 STI). The findings of this study will inform practitioners of the suitability of affordable loudspeakers when standardized special test loudspeakers are not available.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非专用扬声器作为自然声学语音测试源的语音清晰度研究
在自然声学语音通信(NAS)场景中进行的客观语音清晰度估计需要使用接近人类说话者声学特性的语音源。市场上只有数量有限的符合相关指引规格的特殊语音源;然而,专业从业者和其他用户可能会认为它们很昂贵。在NAS调查中,在不了解其适用性和结果有效性的情况下,经常使用非特殊和负担得起的扬声器来代替标准化的特殊语音源。本研究旨在研究一系列具有代表性的普通和负担得起的非特殊扬声器作为NAS指示性或试点调查中标准化语音源的潜在替代方案的适用性。频率响应和语音传输指数公共广播(STIPA)实验结果与在受控实验室条件下使用各种具有实际代表性的NAS声学条件组合测量的各种非特殊扬声器的结果进行了比较。替代语音源的STIPA平均绝对误差普遍低于STIPA方法的不确定性和1个显著差异(0.03 STI)。本研究的结果将告知从业者在没有标准化特殊测试扬声器时可负担得起的扬声器的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊最新文献
Data-Driven Discovery of Anomaly-Sensitive Parameters from Uvula Wake Flows Using Wavelet Analyses and Poincaré Maps Importance of Noise Hygiene in Dairy Cattle Farming—A Review Finite Element–Boundary Element Acoustic Backscattering with Model Reduction of Surface Pressure Based on Coherent Clusters Applying New Algorithms for Numerical Integration on the Sphere in the Far Field of Sound Pressure Sound Environment during Dental Treatment in Relation to COVID-19 Pandemic
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1