{"title":"A supervisory controller intended to arrest dynamic falls with a wearable cold-gas thruster.","authors":"Almaskhan Baimyshev, Michael Finn-Henry, Michael Goldfarb","doi":"10.1017/wtc.2023.18","DOIUrl":null,"url":null,"abstract":"<p><p>This article examines the feasibility of employing a cold-gas thruster (CGT), intended as a backpack-wearable device, for purposes of arresting backward falls, and in particular describes a supervisory controller that, for some motion described by an arbitrary combination of center-of-mass angle and angular velocity, both detects an impending fall and determines when to initiate thrust in the CGT in order to arrest the impending fall. The CGT prototype and the supervisory controller are described and experimentally assessed using a rocking block apparatus intended to approximate a backward-falling human. In these experiments, the CGT and supervisory controller restored upright stability to the rocking block in all experiment cases that would have otherwise resulted in a fall without the CGT assistance. Since the controller and experiments employ a reduced-order model of a falling human, the authors also conducted a series of simulations intended to examine the extent to which the controller might remain effective in the case of a multi-segment human. The results of these simulations suggest that the CGT controller would be nearly as effective on a multi-segment falling human as on the reduced-order model.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2023-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10952053/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2023.18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This article examines the feasibility of employing a cold-gas thruster (CGT), intended as a backpack-wearable device, for purposes of arresting backward falls, and in particular describes a supervisory controller that, for some motion described by an arbitrary combination of center-of-mass angle and angular velocity, both detects an impending fall and determines when to initiate thrust in the CGT in order to arrest the impending fall. The CGT prototype and the supervisory controller are described and experimentally assessed using a rocking block apparatus intended to approximate a backward-falling human. In these experiments, the CGT and supervisory controller restored upright stability to the rocking block in all experiment cases that would have otherwise resulted in a fall without the CGT assistance. Since the controller and experiments employ a reduced-order model of a falling human, the authors also conducted a series of simulations intended to examine the extent to which the controller might remain effective in the case of a multi-segment human. The results of these simulations suggest that the CGT controller would be nearly as effective on a multi-segment falling human as on the reduced-order model.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种监督控制器,旨在通过可穿戴冷气体推进器阻止动态坠落
摘要:本文探讨了采用冷气推力器(CGT)的可行性,该装置旨在作为背包可穿戴设备,用于阻止向后坠落,并特别描述了一个监督控制器,对于由质心角和角速度的任意组合描述的某些运动,该控制器既检测到即将发生的坠落,又确定何时启动CGT中的推力以阻止即将发生的坠落。描述了CGT原型和监控控制器,并使用一个旨在近似向后摔倒的人的摇块装置进行了实验评估。在这些实验中,CGT和监督控制器在所有实验情况下都恢复了摇晃块的直立稳定性,否则如果没有CGT的帮助就会导致坠落。由于控制器和实验采用了人类坠落的降阶模型,作者还进行了一系列模拟,旨在检查控制器在多段人类的情况下可能保持有效的程度。这些模拟结果表明,CGT控制器对多段人体下降的效果几乎与降阶模型一样有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊最新文献
Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis. Acute suppression of lower limb spasm by sacral afferent stimulation for people with spinal cord injury: A pilot study GLULA: Linear attention-based model for efficient human activity recognition from wearable sensors Erratum: Validity of estimating center of pressure during walking and running with plantar load from a three-sensor wireless insole - ERRATUM. A novel neck brace to characterize neck mobility impairments following neck dissection in head and neck cancer patients - ADDENDUM.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1