Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Q3 Health Professions Iranian Journal of Medical Physics Pub Date : 2020-05-01 DOI:10.22038/IJMP.2019.39054.1515
D. Saroj, Suresh Yadav, Gopa Ghosh, Shuchishree Shukla, G. Gupta, Suman Kumar Choudhary
{"title":"Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study","authors":"D. Saroj, Suresh Yadav, Gopa Ghosh, Shuchishree Shukla, G. Gupta, Suman Kumar Choudhary","doi":"10.22038/IJMP.2019.39054.1515","DOIUrl":null,"url":null,"abstract":"Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. \nMaterial and Methods: The present study was conducted on 10 patients with GBM previously planned and treated with 6MV FF photon beam by IMRT technique. Additional IMRT plans were retrospectively created using 6MV FFF photon beam for each patient plan. The dose prescription, beam parameters, and planning objective were kept same in both plans. The plans were evaluated using cumulative dose-volume histogram (c-DVH). Both types of plans were compared on the basis of homogeneity index (HI), conformity index (CI), beam-on time (BOT), monitor unit (MU), and doses to organs at risk (OARs). \nResults: Dose received by 95% (D95%) of planning target volume (PTV) coverage was observed significantly higher in 6MV_FF_IMRT plan than 6MV_FFF_IMRT plan (P<0.05). No significant dose differences were noticed for HI, CI, D98%, and D2% between both plans. Significantly lower Dmax for the brainstem, eyes, and eye lens was observed in 6MV_FFF_IMRT plan. For the brain, less than 2% mean dose was observed in 6MV_FFF_IMRT plan than 6MV_FF_IMRT plan (P=0.017). In 6MV_FFF_IMRT plan, mean BOT decreased by 39% in comparison to that in 6MV_FF_IMRT plans. \nConclusion: The 6MV FFF beam provides a desirable and clinically acceptable IMRT plan for the treatment of GBM than 6MV FF beam. In addition, 6MV FFF beam provides higher MUs, better OARs sparing, lower scattered dose, and lower beam delivery time.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":"17 1","pages":"188-196"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2019.39054.1515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously planned and treated with 6MV FF photon beam by IMRT technique. Additional IMRT plans were retrospectively created using 6MV FFF photon beam for each patient plan. The dose prescription, beam parameters, and planning objective were kept same in both plans. The plans were evaluated using cumulative dose-volume histogram (c-DVH). Both types of plans were compared on the basis of homogeneity index (HI), conformity index (CI), beam-on time (BOT), monitor unit (MU), and doses to organs at risk (OARs). Results: Dose received by 95% (D95%) of planning target volume (PTV) coverage was observed significantly higher in 6MV_FF_IMRT plan than 6MV_FFF_IMRT plan (P<0.05). No significant dose differences were noticed for HI, CI, D98%, and D2% between both plans. Significantly lower Dmax for the brainstem, eyes, and eye lens was observed in 6MV_FFF_IMRT plan. For the brain, less than 2% mean dose was observed in 6MV_FFF_IMRT plan than 6MV_FF_IMRT plan (P=0.017). In 6MV_FFF_IMRT plan, mean BOT decreased by 39% in comparison to that in 6MV_FF_IMRT plans. Conclusion: The 6MV FFF beam provides a desirable and clinically acceptable IMRT plan for the treatment of GBM than 6MV FF beam. In addition, 6MV FFF beam provides higher MUs, better OARs sparing, lower scattered dose, and lower beam delivery time.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
6MV平坦滤光片和平坦无滤光片光子束IMRT治疗胶质母细胞瘤的剂量比较:治疗计划研究
引言:本研究评估了6MV平坦滤光片(FF)和无平坦滤光片(FFF)光子束在强度调制放射治疗(IMRT)技术中治疗胶质母细胞瘤(GBM)患者的剂量学比较。材料和方法:本研究采用IMRT技术,对10例GBM患者进行了6MV FF光子束治疗。使用6MV FFF光子束为每个患者计划回顾性创建额外的IMRT计划。在两个计划中,剂量处方、光束参数和计划目标保持不变。使用累积剂量体积直方图(c-DVH)对计划进行评估。根据同质性指数(HI)、一致性指数(CI)、射束时间(BOT)、监测单位(MU)和危险器官剂量(OAR)对两种类型的计划进行比较。结果:在6MV_FF_IMRT方案中,95%(D95%)的计划目标体积(PTV)覆盖率所接受的剂量显著高于6MV_FFF_IMRT(P<0.05)。两个方案之间的HI、CI、D98%和D2%没有显著的剂量差异。6MV_FFF_IMRT方案中观察到脑干、眼睛和晶状体的Dmax显著降低。在大脑方面,6MV_FFF_IMRT方案的平均剂量低于6MV_FF_IMRT计划的2%(P=0.017)。在6MV_FFF_IMRT方案中,平均BOT比6MV_FF-IMRT方案降低了39%。结论:与6MV FF相比,6MV FFF光束为GBM的治疗提供了一种理想且临床可接受的IMRT方案。此外,6MV FFF光束提供了更高的MU、更好的OAR保留、更低的散射剂量和更低的光束递送时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Medical Physics
Iranian Journal of Medical Physics Health Professions-Radiological and Ultrasound Technology
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊介绍: Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.
期刊最新文献
Secondary cancer risk after radiotherapy of seminoma stage one The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging Scatter radiation absorbed dose distribution in coronary angiography: A measurement based study Evaluation of Low-Dose 3D skull CT images in craniosynostosis Left-sided Breast Cancer Radiotherapy and Risk of Heart Diseases: with Considering Baseline Risk of Heart Diseases
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1