The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging

Q3 Health Professions Iranian Journal of Medical Physics Pub Date : 2021-11-04 DOI:10.22038/IJMP.2021.59219.1996
Mohamdreza Armanmehr, Mohammad Mahdi Jalali, A. Shokri, Ali Heydari Chaleshtori
{"title":"The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging","authors":"Mohamdreza Armanmehr, Mohammad Mahdi Jalali, A. Shokri, Ali Heydari Chaleshtori","doi":"10.22038/IJMP.2021.59219.1996","DOIUrl":null,"url":null,"abstract":"Abstract\nBackground: Sometimes, a patient is referred to a medical imaging center and receives a medical image that it is not good and sometimes poor quality image, which the doctor orders to re-image with a drug contrast agent (in CT scan imaging). On the other hand, small liver tumors sometimes have to reach 4 cm to be detectable. At this time, practical action is difficult to provide a proper image. Moreover, injectable tracking materials in PET scans often have short half-lives that are very expensive to maintain.\nPurpose: \n-Investigation of the effect of cobalt oxide nanoparticles on the quality of CT scan images from laboratory mice.\n-Evaluation of the effect of cobalt oxide nanoparticles on the quality of live PET scan images and diagnosis of small tumors in mice.\nMethod: In this study, the coupling method was used to prepare the cobalt oxide nanoparticles. Co3O4 nanoparticle coatings are used for this purpose. They were investigated through FT-IR analysis, X-ray diffraction and magnetization curve of the crystalline sample. For this purpose a 2000 μA proton bombardment with an energy of 22 million eV and a current of 180 μA was used. The final product activity was 23 mM. A. The nanoparticles were injected into Mice with tumors in the legs, and PET images were obtained at 1, 6, 12, and 24 h intervals.\nResults:\n1- After injection the cobalt oxide nanoparticles into the mice and CT scan imaging, the better clarity and detection Mice viscera were obtained.\n2-Cobalt oxide nanoparticles showed good performance in PET scan images after injection into mice in the first first 24 hours.\nConclusion: Cobalt oxide nanoparticles behave well for use as a pharmacological contrast agent in CT scan and PET scan imaging.\n\nKeywords: PET, tumor, Radiotracer, nanoparticles, CT-Scan.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2021.59219.1996","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Sometimes, a patient is referred to a medical imaging center and receives a medical image that it is not good and sometimes poor quality image, which the doctor orders to re-image with a drug contrast agent (in CT scan imaging). On the other hand, small liver tumors sometimes have to reach 4 cm to be detectable. At this time, practical action is difficult to provide a proper image. Moreover, injectable tracking materials in PET scans often have short half-lives that are very expensive to maintain. Purpose: -Investigation of the effect of cobalt oxide nanoparticles on the quality of CT scan images from laboratory mice. -Evaluation of the effect of cobalt oxide nanoparticles on the quality of live PET scan images and diagnosis of small tumors in mice. Method: In this study, the coupling method was used to prepare the cobalt oxide nanoparticles. Co3O4 nanoparticle coatings are used for this purpose. They were investigated through FT-IR analysis, X-ray diffraction and magnetization curve of the crystalline sample. For this purpose a 2000 μA proton bombardment with an energy of 22 million eV and a current of 180 μA was used. The final product activity was 23 mM. A. The nanoparticles were injected into Mice with tumors in the legs, and PET images were obtained at 1, 6, 12, and 24 h intervals. Results: 1- After injection the cobalt oxide nanoparticles into the mice and CT scan imaging, the better clarity and detection Mice viscera were obtained. 2-Cobalt oxide nanoparticles showed good performance in PET scan images after injection into mice in the first first 24 hours. Conclusion: Cobalt oxide nanoparticles behave well for use as a pharmacological contrast agent in CT scan and PET scan imaging. Keywords: PET, tumor, Radiotracer, nanoparticles, CT-Scan.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氧化钴纳米颗粒对提高CT和PET扫描医学成像质量的影响
背景:有时,患者被转诊到医学成像中心,收到一张质量不好的医学图像,有时质量较差的图像,医生命令用药物造影剂重新成像(在CT扫描成像中)。另一方面,小型肝脏肿瘤有时必须达到4厘米才能被检测到。此时,实际行动很难提供合适的图像。此外,PET扫描中的可注射跟踪材料的半衰期通常很短,维护成本很高。目的:研究氧化钴纳米颗粒对实验室小鼠CT扫描图像质量的影响-评估氧化钴纳米颗粒对活体PET扫描图像质量的影响以及对小鼠小肿瘤的诊断。方法:采用偶联法制备氧化钴纳米粒子。Co3O4纳米粒子涂层用于此目的。通过FT-IR分析、X射线衍射和晶体样品的磁化曲线对它们进行了研究。为此,使用了能量为2200万eV、电流为180μa的2000μa质子轰击。最终产物活性为23mM.A.将纳米颗粒注射到腿部有肿瘤的小鼠中,并以1、6、12和24小时的间隔获得PET图像。结果:1-将氧化钴纳米粒子注射到小鼠体内并进行CT扫描成像后,获得了更好的清晰度和检测小鼠内脏。2-氧化钴纳米粒子在注射到小鼠后的前24小时在PET扫描图像中表现出良好的性能。结论:氧化钴纳米粒子在CT和PET扫描成像中具有良好的药理造影剂性能。关键词:PET,肿瘤,放射性示踪剂,纳米粒子,CT扫描。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Medical Physics
Iranian Journal of Medical Physics Health Professions-Radiological and Ultrasound Technology
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊介绍: Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.
期刊最新文献
Secondary cancer risk after radiotherapy of seminoma stage one The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging Scatter radiation absorbed dose distribution in coronary angiography: A measurement based study Evaluation of Low-Dose 3D skull CT images in craniosynostosis Left-sided Breast Cancer Radiotherapy and Risk of Heart Diseases: with Considering Baseline Risk of Heart Diseases
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1