Electric Field Distribution of Soluble Salt Deposition on the Surface of Insulators in Railway Overhead Lines

Sihua Wang;Junjun Wang;Long Chen;Lei Zhao
{"title":"Electric Field Distribution of Soluble Salt Deposition on the Surface of Insulators in Railway Overhead Lines","authors":"Sihua Wang;Junjun Wang;Long Chen;Lei Zhao","doi":"10.23919/CJEE.2022.000031","DOIUrl":null,"url":null,"abstract":"Different constituents of soluble salts have different effects on the insulation performance of insulators. To study the electric field distribution of soluble salt deposition on the surface of high-speed railway insulators, a two-dimensional model of the cantilever insulator electrostatic field and constant-current field with soluble salt deposition is constructed. The simulation results indicate that the relative dielectric constant of dry pollution is the main factor that affects the electric field distribution on the surface of the insulator. The electric field intensity is arranged in the following order: CaSO\n<inf>4</inf>\n>KNO\n<inf>3</inf>\n>NaNO\n<inf>3</inf>\n>K\n<inf>2</inf>\nSO\n<inf>4</inf>\n>NaCl>MgSO\n<inf>4</inf>\n, and the conductivity of each dirty liquid in the wet state becomes a key factor affecting the electric field distribution, which is specifically shown as sodium chloride>nitrate>sulfate. The simulation results are compared with existing test results to verify that they were correct. It is also found that the electric field intensity of the insulator with good hydrophobicity is slightly greater than that of the insulator without hydrophobicity. The results provide a theoretical basis for the classification of regional pollution levels and the testing of insulator contamination in the laboratory.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/7873788/9915414/09915502.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/9915502/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Different constituents of soluble salts have different effects on the insulation performance of insulators. To study the electric field distribution of soluble salt deposition on the surface of high-speed railway insulators, a two-dimensional model of the cantilever insulator electrostatic field and constant-current field with soluble salt deposition is constructed. The simulation results indicate that the relative dielectric constant of dry pollution is the main factor that affects the electric field distribution on the surface of the insulator. The electric field intensity is arranged in the following order: CaSO 4 >KNO 3 >NaNO 3 >K 2 SO 4 >NaCl>MgSO 4 , and the conductivity of each dirty liquid in the wet state becomes a key factor affecting the electric field distribution, which is specifically shown as sodium chloride>nitrate>sulfate. The simulation results are compared with existing test results to verify that they were correct. It is also found that the electric field intensity of the insulator with good hydrophobicity is slightly greater than that of the insulator without hydrophobicity. The results provide a theoretical basis for the classification of regional pollution levels and the testing of insulator contamination in the laboratory.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
铁路架空线路绝缘子表面可溶性盐沉积的电场分布
不同成分的可溶性盐对绝缘子的绝缘性能有不同的影响。为了研究高速铁路绝缘子表面可溶性盐沉积的电场分布,建立了含可溶性盐沉积的悬臂绝缘子静电场和恒流场的二维模型。仿真结果表明,干污染的相对介电常数是影响绝缘子表面电场分布的主要因素。电场强度的排列顺序为:CaSO4>KNO3>NaNO3>K2SO4>NaCl>MgSO4,各脏液在湿态的电导率成为影响电场分布的关键因素,具体表现为氯化钠>硝酸盐>硫酸盐。将仿真结果与已有的试验结果进行了比较,验证了仿真结果的正确性。还发现疏水性好的绝缘子的电场强度略大于非疏水性绝缘子的电场强度。研究结果为区域污染等级划分和实验室绝缘子污染检测提供了理论依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
期刊最新文献
Contents Front Cover Hybrid Modulation Strategy with Voltage Balancing Control for Four-Level Neutral-Point Clamped Converters Design-Oriented Transient Stability Assessment for Droop-Controlled Converter Considering Grid Voltage Phase-Angle Jump Dynamic Reconstruction of Total-Cross-Tied Photovoltaic Array Based on Arrays Using an Improved Dung Beetle Algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1