Modeling Common-Mode Current Due to Asymmetric Aging of Machine Winding Insulation

Jin Zhao;Aaron D. Brovont
{"title":"Modeling Common-Mode Current Due to Asymmetric Aging of Machine Winding Insulation","authors":"Jin Zhao;Aaron D. Brovont","doi":"10.23919/CSMS.2023.0004","DOIUrl":null,"url":null,"abstract":"Machine stator winding insulation degradation is one of the main results of machine aging. It is non-negligible once this degradation process becomes asymmetric between phases. The traditional way to determine the insulation state of health is a partial discharge test. However, this method requires the system offline, which causes production loss and extra administrative burden. This paper presents an idea for better characterizing the insulation machine's state of health using common-mode (CM) behavior in the machine-drive system. With the help of circuit decomposition methods and modeling tools, the CM quantities due to asymmetric aging show a unique characteristic that distinguishes itself from other differential-mode (DM) quantities in the equivalent circuit. It is shown effective to represent the asymmetric aging effect from the detection of system leakage current. This paper provides an analytical method to quantify this characteristic from mathematical approaches, and a proper approximation has been made on the CM equivalent model (CEM) such that the CM behavior is accurately characterized. The proposed method will serve the purpose of predicting machine abnormal behavior using the simple RLC circuit. Researchers can adapt this method to quantify and characterize the machine insulation state of health (SOH).","PeriodicalId":65786,"journal":{"name":"复杂系统建模与仿真(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/9420428/10158516/10158518.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"复杂系统建模与仿真(英文)","FirstCategoryId":"1089","ListUrlMain":"https://ieeexplore.ieee.org/document/10158518/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Machine stator winding insulation degradation is one of the main results of machine aging. It is non-negligible once this degradation process becomes asymmetric between phases. The traditional way to determine the insulation state of health is a partial discharge test. However, this method requires the system offline, which causes production loss and extra administrative burden. This paper presents an idea for better characterizing the insulation machine's state of health using common-mode (CM) behavior in the machine-drive system. With the help of circuit decomposition methods and modeling tools, the CM quantities due to asymmetric aging show a unique characteristic that distinguishes itself from other differential-mode (DM) quantities in the equivalent circuit. It is shown effective to represent the asymmetric aging effect from the detection of system leakage current. This paper provides an analytical method to quantify this characteristic from mathematical approaches, and a proper approximation has been made on the CM equivalent model (CEM) such that the CM behavior is accurately characterized. The proposed method will serve the purpose of predicting machine abnormal behavior using the simple RLC circuit. Researchers can adapt this method to quantify and characterize the machine insulation state of health (SOH).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于机器绕组绝缘非对称老化的共模电流建模
电机定子绕组绝缘劣化是电机老化的主要结果之一。一旦这种降解过程在各阶段之间变得不对称,它是不可忽略的。确定绝缘健康状态的传统方法是局部放电试验。然而,这种方法需要系统离线,这会造成生产损失和额外的管理负担。本文提出了一种利用电机驱动系统中的共模行为更好地表征绝缘电机健康状态的方法。在电路分解方法和建模工具的帮助下,非对称老化引起的CM量显示出与等效电路中其他差模量不同的独特特征。结果表明,从系统漏电流检测的角度来表征非对称老化效应是有效的。本文提供了一种从数学角度量化这一特性的分析方法,并对CM等效模型(CEM)进行了适当的近似,从而准确地表征了CM的行为。所提出的方法将达到利用简单的RLC电路预测机器异常行为的目的。研究人员可以采用这种方法来量化和表征机器的绝缘健康状态(SOH)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.80
自引率
0.00%
发文量
0
期刊最新文献
Front Cover Contents Research on Digital Twin System Platform Framework and Key Technologies of Unmanned Ground Equipment Hierarchical Disturbance Propagation Mechanism and Improved Contract Net Protocol for Satellite TT&C Resource Dynamic Scheduling Modeling and Analysis of Risk Propagation and Loss Causing Capacity for Key Nodes in Cyber-Physical Coupled Power Network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1