Toby Elery, Emma Reznick, Staci M. Shearin, Karen J. McCain, R. Gregg
{"title":"Design and Initial Validation of a Multiple Degree-of-Freedom Joint for an Ankle-Foot Orthosis","authors":"Toby Elery, Emma Reznick, Staci M. Shearin, Karen J. McCain, R. Gregg","doi":"10.1115/1.4053200","DOIUrl":null,"url":null,"abstract":"\n This paper presents the novel design of a Multi-Degree-Of-Freedom joint (M-DOF) for an Ankle-Foot Orthosis (AFO) that aims to improve upon the commercially available Double Action Joint (DAJ). The M-DOF is designed to maintain the functionality of the DAJ, while increasing dorsiflexion stiffness and introducing inversion/eversion. This increase in range of motion is designed to produce greater engagement from lower limb muscles during gait. The M-DOF was experimentally validated with one able-bodied and one stroke subject. Across walking speeds, the M-DOF AFO minimally affected the able-bodied subject's joint kinematics. The stroke subject's ankle dorsiflexion/plantarflexion and knee flexion were not heavily altered when wearing the M-DOF AFO, compared to the DAJ AFO. The new DOF allowed by the M-DOF AFO increased the inversion/eversion of the ankle by ~3°, without introducing any new compensations compared to their gait with the DAJ AFO.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4053200","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 2
Abstract
This paper presents the novel design of a Multi-Degree-Of-Freedom joint (M-DOF) for an Ankle-Foot Orthosis (AFO) that aims to improve upon the commercially available Double Action Joint (DAJ). The M-DOF is designed to maintain the functionality of the DAJ, while increasing dorsiflexion stiffness and introducing inversion/eversion. This increase in range of motion is designed to produce greater engagement from lower limb muscles during gait. The M-DOF was experimentally validated with one able-bodied and one stroke subject. Across walking speeds, the M-DOF AFO minimally affected the able-bodied subject's joint kinematics. The stroke subject's ankle dorsiflexion/plantarflexion and knee flexion were not heavily altered when wearing the M-DOF AFO, compared to the DAJ AFO. The new DOF allowed by the M-DOF AFO increased the inversion/eversion of the ankle by ~3°, without introducing any new compensations compared to their gait with the DAJ AFO.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.