Analysis of the Refrigeration Performance of the Refrigerated Warehouse with Ice Thermal Energy Storage Driven Directly by Variable Photovoltaic Capacity
Junyu Liang, W. Du, Dada Wang, Xingyu Yuan, Meixi Liu, Kunhao Niu
{"title":"Analysis of the Refrigeration Performance of the Refrigerated Warehouse with Ice Thermal Energy Storage Driven Directly by Variable Photovoltaic Capacity","authors":"Junyu Liang, W. Du, Dada Wang, Xingyu Yuan, Meixi Liu, Kunhao Niu","doi":"10.1155/2022/3441926","DOIUrl":null,"url":null,"abstract":"An independent solar photovoltaic (PV) refrigerated warehouse system with ice thermal energy storage is constructed in this paper. In this system, the vapour compression refrigeration cycle is directly driven by a PV array, and the frequency of the compressor varies with the solar radiation intensity. The refrigeration performance and the matching characteristics of the system driven by different PV capacities are studied. The results show that the intensity of solar radiation required for the compressor to work at the same frequency decreases by approximately 7.8% when the ratio of PV capacity to compressor-rated power increases by 10%, and the time required for the temperature in the refrigerated warehouse to drop from ambient temperature to 0°C is reduced by 32 min on average. The energy efficiency ratio of the vapour compression refrigeration subsystem and the coefficient of performance (COP) of the refrigerated warehouse system increase with the ratio of PV capacity to compressor-rated power α. When α increases from 1 to 1.3, the growth rate of the COP is very slow. For the PV direct-drive refrigerated warehouse system with a compressor-rated power of 4.4 kW, the suitable ratio of PV capacity to compressor-rated power α is about 1.3. When the refrigerated warehouse system is driven directly by a 5.4 kW PV array, the overall COP is approximately 0.19. In the cycle mode of refrigeration and cold energy storage during the day and cold energy release at night, the stored cold energy can still meet the refrigeration required by the load for 48 hours after eight days of continuous operation. According to the current market price of cold storage, during the service life of the system, the income per unit volume of cold storage is about 2.2 times the investment.","PeriodicalId":14195,"journal":{"name":"International Journal of Photoenergy","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Photoenergy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2022/3441926","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 2
Abstract
An independent solar photovoltaic (PV) refrigerated warehouse system with ice thermal energy storage is constructed in this paper. In this system, the vapour compression refrigeration cycle is directly driven by a PV array, and the frequency of the compressor varies with the solar radiation intensity. The refrigeration performance and the matching characteristics of the system driven by different PV capacities are studied. The results show that the intensity of solar radiation required for the compressor to work at the same frequency decreases by approximately 7.8% when the ratio of PV capacity to compressor-rated power increases by 10%, and the time required for the temperature in the refrigerated warehouse to drop from ambient temperature to 0°C is reduced by 32 min on average. The energy efficiency ratio of the vapour compression refrigeration subsystem and the coefficient of performance (COP) of the refrigerated warehouse system increase with the ratio of PV capacity to compressor-rated power α. When α increases from 1 to 1.3, the growth rate of the COP is very slow. For the PV direct-drive refrigerated warehouse system with a compressor-rated power of 4.4 kW, the suitable ratio of PV capacity to compressor-rated power α is about 1.3. When the refrigerated warehouse system is driven directly by a 5.4 kW PV array, the overall COP is approximately 0.19. In the cycle mode of refrigeration and cold energy storage during the day and cold energy release at night, the stored cold energy can still meet the refrigeration required by the load for 48 hours after eight days of continuous operation. According to the current market price of cold storage, during the service life of the system, the income per unit volume of cold storage is about 2.2 times the investment.
期刊介绍:
International Journal of Photoenergy is a peer-reviewed, open access journal that publishes original research articles as well as review articles in all areas of photoenergy. The journal consolidates research activities in photochemistry and solar energy utilization into a single and unique forum for discussing and sharing knowledge.
The journal covers the following topics and applications:
- Photocatalysis
- Photostability and Toxicity of Drugs and UV-Photoprotection
- Solar Energy
- Artificial Light Harvesting Systems
- Photomedicine
- Photo Nanosystems
- Nano Tools for Solar Energy and Photochemistry
- Solar Chemistry
- Photochromism
- Organic Light-Emitting Diodes
- PV Systems
- Nano Structured Solar Cells