{"title":"Continuous Electrophoretic Separation of Charged Dyes in Liquid Foam","authors":"Matthieu Fauvel, A. Trybala, D. Tseluiko, V. Starov, H. C. H. Bandulasena","doi":"10.3390/colloids7020044","DOIUrl":null,"url":null,"abstract":"A novel electrophoretic separation technique is presented, where continuous electrophoretic separation is demonstrated using free flowing liquid foams. Continuous foam electrophoresis combines the principle of capillary electrophoresis and interactions between analytes and the electrical double layer, with the ability of Free Flow Electrophoresis to continuously separate and recover analytes automatically. A liquid foam is used to provide a network of deformable micro and nano channels with a high surface area, presenting a novel platform for electrophoresis, where interfacial phenomena could be exploited to modify analyte migration. The main purpose of this paper is to present a proof-of-concept study and provide fundamental understanding of a complex foam system in continuous separation mode, i.e., flowing liquid foam under an external electric field with electrophoresis and chemical reactions at the electrodes continuously changing the system. Liquid foam is generated using a mixture of anionic and non-ionic surfactants and pumped through a microfluidic separation chamber between two electrodes. The effectiveness of the device is demonstrated using a dye mixture containing a neutral dye and an anionic dye. At the outlet, the foam is separated and collected into five fractions which are individually probed for the concentration of the two dyes used. The anionic dye was concentrated up to 1.75 (±0.05) times the initial concentration in a select outlet, while the neutral dye concentration remained unchanged in all outlets, demonstrating the potential for electrophoretic foam separations.","PeriodicalId":10433,"journal":{"name":"Colloids and Interfaces","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Colloids and Interfaces","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/colloids7020044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A novel electrophoretic separation technique is presented, where continuous electrophoretic separation is demonstrated using free flowing liquid foams. Continuous foam electrophoresis combines the principle of capillary electrophoresis and interactions between analytes and the electrical double layer, with the ability of Free Flow Electrophoresis to continuously separate and recover analytes automatically. A liquid foam is used to provide a network of deformable micro and nano channels with a high surface area, presenting a novel platform for electrophoresis, where interfacial phenomena could be exploited to modify analyte migration. The main purpose of this paper is to present a proof-of-concept study and provide fundamental understanding of a complex foam system in continuous separation mode, i.e., flowing liquid foam under an external electric field with electrophoresis and chemical reactions at the electrodes continuously changing the system. Liquid foam is generated using a mixture of anionic and non-ionic surfactants and pumped through a microfluidic separation chamber between two electrodes. The effectiveness of the device is demonstrated using a dye mixture containing a neutral dye and an anionic dye. At the outlet, the foam is separated and collected into five fractions which are individually probed for the concentration of the two dyes used. The anionic dye was concentrated up to 1.75 (±0.05) times the initial concentration in a select outlet, while the neutral dye concentration remained unchanged in all outlets, demonstrating the potential for electrophoretic foam separations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
液体泡沫中带电染料的连续电泳分离
提出了一种新的电泳分离技术,其中连续电泳分离演示使用自由流动的液体泡沫。连续泡沫电泳结合了毛细管电泳的原理和分析物与电双层之间的相互作用,具有自由流动电泳的能力,可以自动连续分离和回收分析物。液体泡沫用于提供具有高表面积的可变形微纳米通道网络,为电泳提供了一个新的平台,可以利用界面现象来改变分析物的迁移。本文的主要目的是进行概念验证研究,并对连续分离模式下的复杂泡沫系统进行基本理解,即在外电场下流动的液体泡沫,电极上的电泳和化学反应不断改变系统。液体泡沫是使用阴离子和非离子表面活性剂的混合物产生的,并通过两个电极之间的微流体分离室泵送。使用含有中性染料和阴离子染料的染料混合物证明了该装置的有效性。在出口处,泡沫被分离并收集成五个部分,这些部分被单独探测用于所使用的两种染料的浓度。阴离子染料在特定出口的浓度可达到初始浓度的1.75(±0.05)倍,而中性染料在所有出口的浓度保持不变,表明电泳泡沫分离的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Colloids and Interfaces
Colloids and Interfaces CHEMISTRY, PHYSICAL-
CiteScore
3.90
自引率
4.20%
发文量
64
审稿时长
10 weeks
期刊最新文献
Co-Encapsulation of Paclitaxel and Doxorubicin in Liposomes Layer by Layer Study of Interfacial Properties of Anionic–Nonionic Surfactants Based on Succinic Acid Derivatives via Molecular Dynamics Simulations and the IGMH Method Discontinuous Shear Thickening of Suspensions of Magnetic Particles in Relation to the Polymer Coating on Their Surfaces Flowable Electrodes from Colloidal Suspensions of Thin Multiwall Carbon Nanotubes A Review of Investigations and Applications of Biocides in Nanomaterials and Nanotechnologies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1