QUALITY CONTROL OF PACKED RED CELL (PRC) PRODUCT IN BLOOD DONATION UNIT

Silvi Astutiningtiyas, Luthfi Rusyadi, Y. Kartikasari
{"title":"QUALITY CONTROL OF PACKED RED CELL (PRC) PRODUCT IN BLOOD DONATION UNIT","authors":"Silvi Astutiningtiyas, Luthfi Rusyadi, Y. Kartikasari","doi":"10.31983/jrk.v11i1.8506","DOIUrl":null,"url":null,"abstract":"Blood Transfusion Service Standards aim to ensure the safety high quality and sufficient blood services sufficient blood reserve. The standard for blood requirements for each country according to WHO is at least 2% of the total population. The population in Indonesia has increased every year so the need for blood is also increasing causing demands for causing the quality of blood services to be better. One of the demands for the quality of blood services by knowing is to know the quality control of the blood produced. One of the blood products produced is PRC. PRC Packed Red Cells quality control checks must be carried out to determine the quality of the PRCs produced.  This study aims to determine the overall quality control of PRC and the results of PRC quality control based on (volume, hemoglobin, hematocrit, hemolysis, and bacterial contamination) in the Blood Donation Unit of Banyumas Regency in 2020. This type of research is descriptive. Sampling technique with a sample quota as much as the total sample quality control packed red cell test obtained 1% of the total production of PRC components every month in the Blood Donation Unit of Banyumas. The QC research results were obtained from 430 PRC samples that met the passing standards: 426 samples (99%) volume, 426 samples (99%) hemoglobin, 380 samples (88%) hematocrit, 429 samples (99.7%) hemolysis, and 426 samples (99%) passed from bacterial contamination. The number of QCs who qualified was 373 samples (87%). These results indicate that the 2020 PRC QC obtained good and satisfying results.","PeriodicalId":52993,"journal":{"name":"Jurnal Riset Kesehatan","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Riset Kesehatan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jrk.v11i1.8506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Blood Transfusion Service Standards aim to ensure the safety high quality and sufficient blood services sufficient blood reserve. The standard for blood requirements for each country according to WHO is at least 2% of the total population. The population in Indonesia has increased every year so the need for blood is also increasing causing demands for causing the quality of blood services to be better. One of the demands for the quality of blood services by knowing is to know the quality control of the blood produced. One of the blood products produced is PRC. PRC Packed Red Cells quality control checks must be carried out to determine the quality of the PRCs produced.  This study aims to determine the overall quality control of PRC and the results of PRC quality control based on (volume, hemoglobin, hematocrit, hemolysis, and bacterial contamination) in the Blood Donation Unit of Banyumas Regency in 2020. This type of research is descriptive. Sampling technique with a sample quota as much as the total sample quality control packed red cell test obtained 1% of the total production of PRC components every month in the Blood Donation Unit of Banyumas. The QC research results were obtained from 430 PRC samples that met the passing standards: 426 samples (99%) volume, 426 samples (99%) hemoglobin, 380 samples (88%) hematocrit, 429 samples (99.7%) hemolysis, and 426 samples (99%) passed from bacterial contamination. The number of QCs who qualified was 373 samples (87%). These results indicate that the 2020 PRC QC obtained good and satisfying results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
献血单位包装红细胞产品的质量控制
输血服务标准旨在确保安全、高质量和充足的血液服务和充足的血液储备。根据世卫组织,每个国家的血液需求标准至少为总人口的2%。印度尼西亚的人口每年都在增加,因此对血液的需求也在增加,这就要求提高血液服务的质量。通过了解对血液服务质量的要求之一是了解所生产血液的质量控制。生产的血液制品之一是PRC。必须进行PRC包装红细胞质量控制检查,以确定所生产的PRC的质量。本研究旨在确定Banyumas摄制区献血单位2020年PRC的整体质量控制情况以及基于(体积、血红蛋白、红细胞压积、溶血、细菌污染)的PRC质量控制结果。这种类型的研究是描述性的。样品配额与总样品质控填充红细胞试验相同的取样技术,使Banyumas献血单位每月PRC组分总产量达到1%。430份PRC样品QC研究结果符合合格标准:体积426份(99%),血红蛋白426份(99%),红细胞压积380份(88%),溶血429份(99.7%),细菌污染426份(99%)。合格质量员373个(87%)。这些结果表明,2020年PRC QC取得了良好的满意效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
11
审稿时长
6 weeks
期刊最新文献
Quality Of Life For Adolescents With Divorced Parents On Physical And Psychological Conditions In Indonesia: Literature Review Analysis of P4K Filling in The MCH Book with Factor of Maternal Death Based on Three Delays (3T) in 2022 In The Jember District Assessing Efficiency and Image Quality of Dental Radiography Using Modified Dental Holders with Silicone Rubber Integration Risk Factors for Dental Caries in Elementary School Children Aged 6-12 in Indonesia (Systematic Literatur Review) Factors Associated With Administration of Antiplatelet Therapy on The NIHSS Score in Acute Ischemic Stroke
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1